Model 2039 is a revolutionary series of portable wattmeters in which a power factor is used to operate the DC indicator. This is done using a transducer which provides a DC current proportionate to the voltage-current phase by means of a circuit. Model 2039 can be used in single-phase and balanced three-phase circuits. The electronic transducer, combined with a high sensitivity moving coil type indicator based on YOKOGAWA's proprietary taut-band suspension system, provides a level of performance not possible with conventional power factor meters.
Rated Current | 0.2/1 A |
---|---|
Rated Voltage | 120V (Used between 60 and 300 V.) |
Operating Principle | Rectifier type |
Class | JIS C 1102 : 1997 Class 3.0 |
Operating Position | Horizontal |
Rated Frequency | 45 ~ 65 Hz |
Scale Length | Approximately 135 mm (Deflection Angle: 85°) |
Scale | Lead 0-0.3 to 1.0 to 0.3-0 lag (with phase angle scale) |
Effective Measurement Range | Lead 0.5 to 1.0 to 0.5 lag |
Approx. Consumed Power Voltage Circuit (120 V) | 0.14 VA |
Approx. Current Circuit (5 A) | 2.4 VA |
Operating Temperature Range | 0 ~ 40 ºC |
Operating Humidity Range | 30 ~ 75% RH |
Storage Temperature Range | -10 ~ 50 ºC |
Storage Humidity Range | 25 ~ 80% RH |
Approx. External Dimension | 260 x 180 x 115 mm |
Approx. External Weight | 2.9 kg |
Optional Accessories | 2292 01 Carrying case |
Features
Rated Current | 1/5A |
---|---|
Rated Voltage | 120V (Used between 60 and 300 V.) |
Operating Principle | Rectifier type |
Class | JIS C 1102 : 1997 Class 3.0 |
Operating Position | Horizontal |
Rated Frequency | 45 ~ 65 Hz |
Scale Length | Approximately 135 mm (Deflection Angle: 85°) |
Scale | Lead 0-0.3 to 1.0 to 0.3-0 lag (with phase angle scale) |
Effective Measurement Range | Lead 0.5 to 1.0 to 0.5 lag |
Approx. Consumed Power Voltage Circuit (120 V) | 0.14 VA |
Approx. Current Circuit (5 A) | 2.4 VA |
Operating Temperature Range | 0 ~ 40 ºC |
Operating Humidity Range | 30 ~ 75% RH |
Storage Temperature Range | -10 ~ 50 ºC |
Storage Humidity Range | 25 ~ 80% RH |
Approx. External Dimension | 260 x 180 x 115 mm |
Approx. External Weight | 2.9 kg |
Optional Accessories | 2292 01 Carrying case |
Features
Rated Current | 5/25A |
---|---|
Rated Voltage | 120V (Used between 60 and 300 V.) |
Operating Principle | Rectifier type |
Class | JIS C 1102 : 1997 Class 3.0 |
Operating Position | Horizontal |
Rated Frequency | 45 ~ 65 Hz |
Scale Length | Approximately 135 mm (Deflection Angle: 85°) |
Scale | Lead 0-0.3 to 1.0 to 0.3-0 lag (with phase angle scale) |
Effective Measurement Range | Lead 0.5 to 1.0 to 0.5 lag |
Approx. Consumed Power Voltage Circuit (120 V) | 0.14 VA |
Approx. Current Circuit (5 A) | 2.4 VA |
Operating Temperature Range | 0 ~ 40 ºC |
Operating Humidity Range | 30 ~ 75% RH |
Storage Temperature Range | -10 ~ 50 ºC |
Storage Humidity Range | 25 ~ 80% RH |
Approx. External Dimension | 260 x 180 x 115 mm |
Approx. External Weight | 2.9 kg |
Optional Accessories | 2292 01 Carrying case |
Features
Model | Description |
---|---|
2039 01 | 0.2/1 A, 45 ~ 65 Hz, 0 ~ 40 deg C, 260 x 180 x 115 mm |
2039 02 | 1/5A, 45 ~ 65 Hz, 0 ~ 40 deg C, 260 x 180 x 115 mm |
2039 03 | 5/25A, 45 ~ 65 Hz, 0 ~ 40 deg C, 260 x 180 x 115 mm |