OSA Macro Program Function

OSA Macro Program Function

The OSA Macro Program Function enables automated measurement by creating programs for entry of measurement conditions and other tasks. Users can program a sequence of measurement procedures from entry of measurement conditions (e.g., wavelength sweep width, setting resolution) to analyses, data saving, output, and others and eliminates redundant procedures on the production line. The function acts as a controller of other connected devices through the LAN or RS232C port and allows users to build an automatic measuring system without using an external PC and input measurement conditions or output measured results while programs are running.

OSA Macro Program Function | Yokogawa Test&Measurement

Produtos e Soluções Relacionadas

AQ6360 Telecom Production 1200 - 1650 nm

  • 0.1 nm resolution
  • ±20 pm accuracy
  • 55 dB dynamic range
  • -80 dBm level sensitivity
  • High sweep speed for manufacturing

AQ6361 Telecom Production 1200-1700 nm

  • 0.03 nm resolution
  • ±20 pm accuracy
  • 55 dB dynamic range
  • -80 dBm level sensitivity
  • Highest sweep speed for manufacturing

AQ6370E Telecom 600 - 1700 nm

  • 0.02 nm resolution
  • ±8 pm accuracy
  • 67 dB dynamic range
  • -90 dBm level sensitivity
  • singlemode and multi-mode

AQ6373E Visible Wavelength 350 - 1200 nm

  • 0.02 nm resolution
  • ±50 pm accuracy
  • 60 dB dynamic range
  • -80 dBm level sensitivity
  • singlemode and multi-mode
  • industrial & biomedical laser testing

AQ6374E Wide Wavelength Range 350 - 1750 nm

  • 0.05 nm resolution
  • ±50 pm accuracy
  • 60 dB dynamic range
  • -80 dBm level sensitivity
  • singlemode and multi-mode
  • visible to communications wavelengths

AQ6375E Long Wavelength 1200 to 2400 nm and 1000 to 2500 nm

  • 0.05 nm resolution
  • ±50 pm accuracy
  • 55 dB dynamic range
  • -70 dBm level sensitivity
  • singlemode and multi-mode
  • NIR and SWIR wavelengths

AQ6376E Three Micron 1500 - 3400 nm

  • 0.1 nm resolution
  • ±0.5 nm accuracy
  • 55 dB dynamic range
  • -65 dBm level sensitivity
  • singlemode and multi-mode
  • SWIR and MWIR wavelengths

AQ6377 Five Micron 1900 - 5500 nm

  • 0.1 nm resolution
  • ±0.5 nm accuracy
  • 50 dB dynamic range
  • -60 dBm level sensitivity
  • singlemode and multi-mode
  • MWIR wavelengths

AQ6380 Highest Performance 1200 - 1650 nm

  • 0.005 nm (5 pm / 0.624 GHz) resolution
  • ±5 pm accuracy
  • 67 dB dynamic range
  • -85 dBm level sensitivity
  • O, C, and L-bands

Optical Spectrum Analyzers

  • Optical Spectrum Analyzer to measure and display power distribution of an optical source
  • Optical analyzer trace displays power in vertical scale and wavelength in horizontal scale

Precision Making

Topo