The WT3000 is the ideal measurement solution for applications such as product efficiency testing, engineering, R&D work on inverters, motor drives, lighting systems and electronic ballasts, UPS systems, aircraft power systems, transformer testing and other power conversion devices.
Updates:
June 29, 2015
With basic power accuracy of ±0.02% reading, DC and 0.1 Hz-1 MHz measurement bandwidths, and up to four input elements, the WT3000 provides higher-accuracy measurement of I/O efficiency.
*As compared to Yokogawas WT2000
In developing the WT3000, Yokogawa focused on improving efficiency in two basic areas. One goal was to obtain highly precise and simultaneously measurements of the power conversion efficiency of a piece of equipment. The other objective was to improve equipment evaluation efficiency by making simultaneous power evaluations and tests easier and faster.
The Yokogawa WT2000 was very popular with users and considered highly reliable because of its high precision and excellent stability. The WT3000 is based on a measurement system which combines the measurement technology used in the WT2000 as well as other WT Series models. With the WT3000, we made further improvements to the basic performance specifications for even better functionality and reliability. We are confident users will appreciate these improvements to power and efficiency measurements thanks to the new power control technologies we have introduced.
The WT3000 is the first model in the WT Series which is standard- equipped with a PC card slot (ATA flash card slot). This interface allows data to be saved quickly, so data processing time is reduced. The WT3000 is also standard-equipped with a GP-IB port. In addition, a serial (RS-232) port, Ethernet port, and USB port are available as options. The variety of interface choices allows customers to use the best interfaces for a wide variety of equipment, media, and network environments.
Yokogawa's highest-precision power analyzer *1 The WT3000 has the highest precision of all the Yokogawa power analyzers in the WT series. The models in the WT series are designed to meet a wide variety of user needs. The WT300 series is a high price-performance series which is very popular in production line applications. The WT1800 allows measurement data to be viewed in a variety of ways, including numerical value display, waveform display, and trend display capabilities.
*2 Reading error |
Model | Description |
---|---|
760301 | WT3000 1 input element model |
760302 | WT3000 2 input element model |
760303 | WT3000 3 input element model |
760304 | WT3000 4 input element model |
For connection the external input of the WT3000 to the current sensor.
Length: 50cm
BNC-BNC 2m. For connection to simultaneously measurement with 2 units, or for input external trigger signal.
Printer Paper Roll
Thermal paper (10m) for WT1600, WT 1800, WT3000, & WT3000E - 1 roll
Rated at 300 V. Attaches to the 758917 test leads. Sold in pairs.
For conversion between BNC and female banana plug
Applicable for DL750/DL750P, SL1000 & SL1400.
Compact instrument cart
500 mm (W) x 560 mm (D) x 705 mm (H)
/A option: keyboard, mouse table
/B option: comes with a 3-prong power strip
All-purpose rolling instrument cart.
Measurement of Power Consumption in Mobile Phones
High Accuracy Measurements of Transformers
Reference equipment for power calibration
Measuring Conversion Efficiency of Power Conditioner
Energy consumption in low-power and standby modes is an important issue due to increased awareness that energy resources are becoming limited and demand for energy-saving household electrical appliances continues to grow. IEC62301 Ed2.0 (2011) and EN 50564:2011 define standby mode as the lowest energy consumption of an appliance not performing its main function, when connected to the mains. IEC62301 Ed2.0 (2011) defines test methods and requirements for both the mains supply and the test equipment. It is crucial that design and test engineers choose highly accurate power measurement tools to confirm that their devices meet these requirements.
"Error(Code:846): Attempted to start integration while measurement of peak overflow was in progress"The following error code will appear if Peak Over has occurred and you attempt to start integration. The WT3000 has two ...
The AC Power Input in all Yokogawa instruments is designed as a 3-pin connection (one of which is a GND pin). In some parts of the world, PCs are sold with AC power cables that are 2-pin. Often times this means the ...
It is not necessary to specify the accuracy for PST values outside the range of 1.0, as any value larger than 1.0 is non-standard. The standard (IEC 61000-3-3) requires that the value of the short-term light ...
The circuit design for the line filters used on the WT & PZ series instruments are similar to Butterworth filters but have been redesigned. We redesigned the original filtering characteristic to obtain a ...
There are no built-in over temperature protection devices in the WT3000. The official operating range covered by warranty is listed at 5°C - 40°C. Our own internal test have revealed that it is possible to ...
Although WTViewer is not officially supported under the Linux environment, users have successfully done so using WINE (flavor of Linux) via RS232. For connectivity to WT210/WT230, WTViewer requires that the meter be set ...
To use the WT3000 with the Flicker Software, the WT3000 Precision Power Analyzer must have the following options: /G6 option - Advanced Calculations /FL option - Flicker Measurements 1 to 3 elements - 30A Input Module Note: The 2A input ...
The following product tutorial guides have been created for the WT and PZ Series Power Meter and Analyzer instruments and are available for download. Each tutorial contains quick and easy steps to help you get started ...
Output function: HArWhen the default output item is set to 1, the printout time for up to the 50th order is about 116 seconds. The printout time for up to the 25th order is about 75 seconds. Output function: HArWhen the ...
The output resolution for the WT3000 is 16-bits.
When the selected data update cycle of the fundamental wave is shorter than the width of the analysis window determined by the fundamental frequency (cycle of the fundamental wave), measurement is not performed and no ...
Selecting formulas for calculating apparent power and reactive powerThere are several types of power—active power, reactive power, and apparent power. Generally, the following equations are satisfied:Active power P = ...
The waveform may actually not be a pure sine wave. Even though a 50/60 Hz sine wave is expected, the following factors may be involved: The waveform is slightly distorted (harmonic components are mixed in) Small ...
Check for differences in the specifications or features of the instruments. For values that do not match when inputting a 50/60 sine wave Check whether the value is within the specifications (error) of each power ...
The measurement intervals of the measured I/O data must overlap exactly. Check the sync source setting. For example, route the input to a three-phase device under measurement to input elements 1-3 on the power meter, ...
Check for differences in the specifications or features of the instruments. For values that do not match when inputting a 50/60 sine wave Check whether the value is within the specifications (error) of each power ...
In the three-phase three-wire, or 3V3A wiring scheme, the phase angle of voltage between each input element is 60 degrees because it is the line to line voltage that is measured. Please download and refer to the ...
In the three-phase three-wire, or 3V3A wiring scheme, the phase angle of voltage and current input to each input differs from that of the actual load because it is the line to line voltage that is measured. In ...
When measuring input signals of distorted waves, signals that are DC-offset or signals that include superimposed harmonic components, will result in different values for power factor and phase angle than those expected ...
The peak value and crest factor may be unstable if they have not been captured accurately. If the peak value is not stable, neither will the crest factor be stable. The cause is the difficulty in capturing the narrow ...
The difference in measurement values can be attributed to the difference in calculation methods for normal mode and harmonic mode. The voltage, current, and power in normal mode are displayed as the total of the ...
The following may be causing the problem. 5V may have occurred during rating. Check the range setting again. DA output error can affect the values when the input is smaller than the rating. Have you checked the error ...
Check the Synch Source and Frequency Filter settings When a single-phase signal being measured fluctuates around power factor of 1.Slight fluctuations in the measured values of voltage, current, and power can cause a ...
There are restrictions of the DSP hardware. WT230 and WT210 are low-cost power meters. So, a low-cost, modest performance DSP utilized.This DSP has slow calculation. WT3000 is performing complicated ...
What is the maximum size of ATA Flash Card we can use with the WT3000? The maximum size of the card to save data is 16GByte. The maximum size of the card used for firmware updating procss is limited to 256MByte.(A ...
The WT3000 enables users to save the waveform data via two methods: waveform displayed data, and waveform sampled data. The number of data points saved by the waveform displayed data method is compressed to a total ...
When the WT1600 Digital Power Analyzer is set into Integration mode, the averaged power (watt) values can be calculated and displayed. This is available only by using the User-Defined Function feature found in the MEASURE button menu. The ...
The WT1800 and WT3000 series digital power analyzer offer two calculation methods, Type1 and Type3, for apparent and reactive power. Type1:The WT will first calculate the RMS voltage Urms, current Irms, and active ...
You can not use LabVIEW and WTviewer to communicate with the PC using same USB driver. The USB driver for LabVIEW and the USB driver for WTviewer is different. Yokogawa's YKMUSB driver is used by WTviewer ...
There are several items you will need to check and verify to solve this issue. Verify the GP-IB connectionSome instruments have a D/A output connector located next to the GP-IB connector. There have been some ...
Unfortunately the WT3000 cannot display the RMS and DC values of voltage/current at the same time, even if you use the user-defined function feature. You must select either RMS or DC mode in the Voltage/Current Range ...
The IEC Harmonic analysis on the DL/DLM series oscilloscopes provides a rough analysis and estimation for harmonic testing. The scope will perform an FFT on the current waveform and can be used to measure the general ...
The value depends on the model of the power analyzer. For Precision Power Analyzer WT1000, WT2000, WT100, and WT200, it is fixed to the fundamental wave. For power analyzers with 7 segments LED, the relative harmonic content is fixed to the ...
The Precision Power Analyzer WT3000 D/A output terminal is electrically isolated from the case. For all other models, the D/A output terminal is connected to the case.
This training module covers the following topics:
While DC power measurements are relatively straight forward, AC power measurements that include distorted waveforms, varying power factors, and multiple phases can add complexity to an otherwise simple measurement. During this webinar, we cover multiple fundamentals of power measurement.
Key topics include: