Oscilloscope Accessories

Yokogawa offers a range of oscilloscope accessories, including rack mount kits, probe accessories, BNC cables, alligator clips, carrying cases, and more. Our variety of accessories for oscilloscopes provide everything you need to connect to your signals.

Passive Probe, 600Vp, 200MHz, 1:1 & 10:1 switchable, 1MΩ/10MΩ, 1.5m,
This is the standard passive probe included with a DL1600.

A 400 MHz passive probe designed for the DL1700E series, and DL7400 series SignalExplorers with switchable attenuation ratio of 1/10 and 1/1.

Passive Probe, 600Vp, 500MHz, 10:1, 10MΩ, 1.3m
Supplied standard with DLM3000.

Passive Probe, 600Vp, 200MHz, 10:1, 10MΩ, 1.5m
Supplied standard with DLM2000/DLM4000.

Passive Probe, 600Vp, 500MHz, 10:1, 10MΩ, 1.3m
Supplied standard with DLM2000/ DLM4000.

Passive Probe, 'PB500', 600Vp, 500MHz, 10:1, 10MΩ, 1.5m
Supplied standard with DL9000/SB5000.

Passive Probe, 400Vrms, 500MHz, 10:1, 10MΩ, 1.2m, 'Mini'
Typically used with DL1700 and DL7400 as an optional non-standard probe.

Passive Probe, 400Vrms, 350MHz, 10:1, 10MΩ, 3.0m, 'Mini'
Optional probe for use with DL1600/DL1700/DL7400 series, see also 701941.

Passive Probe, 400Vrms, 500MHz, 10:1, 10MΩ, 1.3m, 'Miniature Passive Probe' w/ accy kit.
Optional probe for DLM2000/ DLM4000/ DL6000/ DLM6000/ DL9000/ SB5000 series.
Can also be ordered as a substitute for the standard probe when ordering DLM2000/ DL6000/ DLM6000.

Passive Probe, 1000Vrms, 400MHz, 100:1, 50MΩ, 1.2m, 'Mini'
For DL1700, DLM2000, DLM4000, DL/DLM6000,DL9000 and SB5000.
See also 701945 for 250 MHz version of this same probe.

Passive Probe, 1000Vrms, 250MHz, 100:1, 50MΩ, 3.0m, 'Mini' with extra-long 3m lead.  Compatible with DL1700, DLM2000, DLM4000, DL/DLM6000, DL9000 and SB5000. See also 701944 for 400 MHz version of this same probe.

Passive Probe, 1000V(DC+ACpeak) CAT II, 200MHz, 10:1, 10MΩ, 2.5m
Wide operating temperature range(-40 to 85°C)
For DLM2000 and DLM4000 series

The PBL5000 low-capacitance "transmission line" probe (passive) features both 10:1 and 20:1 attenuation.

Active Probe, 10Vp, 900MHz, 10:1, 2.5MΩ / 1.8pF, 1.5m, FET Probe w/ LEMO power pig-tail

Differential probe powered by Yokogawa Digital Oscilloscopes, ScopeCorders, external power supply or internal battery.

Differential probe powered by internal battery.

Differential Probe, 12Vp Differential, 30Vp Common-Mode, 500MHz, 10:1, 100kΩ, w/ built-in power cable (LEMO lead)

Bandwidth: DC to 100 MHz (-3 dB)

The 701922 is a 10:1 Differential Probe rated at 20Vpeak differential voltage input and 60Vpeak Common-Mode input with 200MHz bandwidth (-3dB). This probe is recommended for CAN bus and can be used with virtuallly any oscillscope with an internal 50Ω termination or use the external 50Ω 700976. This probe is powered via a built in pig-tail LEMO lead. This probe can be powered with Yokogawa scope option /P2 or /P4, or an external power supply 700938-3-D or 701934-D. The probe is supplied with one each pinchers, B9852MF black and B9852MG red and a 50cm ground extension.

The PBDH1000 (701924) is a 25Vp Differential Probe powered by the Yokogawa Probe Interface. This probe can be used only with the Yokogawa DLM2000, DL6000, DLM6000, DL9000, and SB5000 series oscilloscope. 

High Voltage Differential probe powered by Yokogawa Digital Oscilloscopes, ScopeCorders, external power supply or internal battery.

The 701927 is a 50:1 or 500:1 high voltage (1400V peak) probe with extended bandwidth covering DC to 150MHz, This probe provides a balanced differential input, to be used with oscilloscopes with single-ended inputs (1 MΩ Input Impedance).  This probe works with DLM2000, DLM4000, DL6000, DLM6000, DL9000 and SB5000. This probe is conveniently powered by the Yokogawa Probe Interface.

Frequency bandwidth: DC to 50 MHz

Maximum continuous input range: 5 Arms

Functions with Digital Oscilloscopes, ScopeCorders and other waveform measuring instruments.  

Frequency bandwidth: DC to 120 MHz

Maximum continuous input range: 5 Arms

Functions with Digital Oscilloscopes, ScopeCorders and other waveform measuring instruments.

Current probe front-end powered, recognized automatically and adjust zero position from the operation of the DLM2000, DLM3000, DLM4000, DL6000/DLM6000, DL9000/DLM9000 and SB5000 series.

Current probe front-end powered, recognized automatically and adjust zero position from the operation of the DLM2000, DLM3000, DLM4000, DL6000/DLM6000, DL9000/DLM9000 and SB5000 series.

Current probe powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply.

Current probe powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply.

Current probe powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply.

Current probe powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply.

A power supply for current probes, FET probes, and differential probes. Supplies power for up to four probes, including large current probes.

The B9852MJ cable supplies power to the 700924, 700925 and 701921 differential probes* from the DL probe power con-nectors. (The probe power option is re-quired on the DL unit.)
* Cable only works with newer 700924, 700925 and 701921 probes that indicate "6VDC or 9VDC"at the probe input power connector. 

Improve switching-loss measurements by eliminating skew.  The 701936 Deskew Correction Signal Source accommodates both clamp-on current probes and through-type ‘CT' Current Transformers.

701988 (PBL100) Logic Probe

100 kΩ input resistance, toggle frequency of 250 MHz

A clip set designed for the 700988, 700960 and 701940 probes.

Attached to the tips of logic probe (701988 or 701989) or mini-clips (B9852CR), the IC clips can be used to clip contiguous 0.5-mm pitch terminals. A total of 10 clips are included.

Logic probe accessory kit for use with 701989.

BNC-Banana-jack (female) adapter. Use for circuits having voltage levels no greater than 42 V.

Banana-plug (male)-BNC adapter. Use for circuits having voltage levels no greater than 42 V.

T-adapter for BNC connectors. Use for circuits having voltage levels no greater than 42 V.

For 701937, 701938, 701939, 701943 (PB500) and 700939.
Quantity of 1 unit: 10

For 701937,701938, 701939, 701943 (PB500) and 700939 Standard accessories include: Adapter, red wire (3), black wire (3)

Safety-terminal-binding-post adapter. Use for circuits having voltage levels no greater than 42 V.

For conversion between BNC and female banana plug
Applicable for DL750/DL750P, SL1000 & SL1400.

A set of 0.8m long red and black test leads, used in combination with a pair of optional 758922 or 758929 alligator-clip adapters.

Used to connect an oscilloscope having a 1M-ohm input to a probe with a 50-ohm output. It is required when using the 701920 and 701922 probes with the DL1600 series.

A clip set designed for 701937, 701938, 701939, 701943 (PB500) and 700939

For 701937,701938, 701939, 701943 (PB500) and 700939.

1000 Vrms-CAT II, 1.8 m long
Safety BNC(male) to safety banana(female) use in combination with 701959, 701954, 758921, 758922 or 758929.

Set contains one black and one red clip
1000 Vrms-CAT II
2 pieces (red and black) in 1 set 
Connected to the 758933, 758917, or 701901
Length: 0.3m
Applicable for DL750/DL750P, SL1000, SL1400

Connected to the 700929, 701947
Maximum input voltage: 1,000V (DC + ACpeak)
Length: 0.26m/0.3m/0.4m
Applicable for DL750/DL750P, SL1000, SL1400

Set contains one black and one red clip.
1000 Vrms-CAT II.

Rated at 1000V. Attaches to the 758917 test leads. Sold in pairs.

Rated at 300 V. Attaches to the 758917 test leads. Sold in pairs.

Adapters for fitting a 4mm banana plug to a fork terminal. Set contains one black and one red clip. 1000 Vrms-CAT II.

Two adapters to a set for 5 A current
(screw-fastened type using B9317WD)

The B9852HF contains the following eleven(11) kinds of accessories: Insulation cap, IC cap, BNC adapter, Rigid tip, Spring tip (Ø: 0.80 mm), Spring tip (Ø: 0.38 mm), Ground spring, Adjustment tool, Pincher tip, Standard ground lead, Color coding rings. PBL5000.

This DC block can be used to remove the DC component from an incoming signal. Use this block if you want to remove bias voltage from reaching the PBL5000 probe.

Screws for B8200JQ, D-SUB connector

BNC-BNC 1m. For connection to simultaneously measurement with 2 units, or for input external trigger signal. 

BNC-BNC 2m. For connection to simultaneously measurement with 2 units, or for input external trigger signal.

A 1 m long BNC-alligator clip cable.
Use only for circuits having voltage levels no greater than 42 V.
Applicable for DL750/DL750P, SL1000 & SL1400

A subassembly of 1.2 m long test leads with alligator-clip adapters.
Use only for circuits having voltage levels no greater than 42 V.
Applicable for SL1000 & SL1400.

This cable is used to connect an external device, however, do not use this cable for purposes other than DL750/1600/1700/1700E/7400 GO/NO-GO judgement.

Using a probe stand with a flexible arm and heavy base to hold and stabilize probes can simplify circuit board testing.

Quality paper for the DLM2000 /DLM4000 /DL850 /DL6000 /DL9000 and DL750

Quality paper for the DLM6000/DL9700/DL9500/DL1700(E)/DL1600/DL1500 and DL7400

Quality paper for the DL750P and the SL1400.
Paper width: 210 mm (A4 size)
Paper length: 20 m
Order Qty: 6 (1set)

For DLM4000 series

Three pockets are provided for storing accessories and the user’s manual.

Three pockets are provided for storing accessories and the user’s manual.

For the DC power supply model (-DC).

Soft Case for Accessories

Convenient and practical for storing accessories (probes, etc). It can be attached to the DL750’s front panel protective cover.

Ideal for storing accessories (probes, etc).

Rack mount kit for DLM4000 series.
EIA/JIS sandard compliant.

Overview:

After a disastrous 2009, the large publicly held test companies enjoyed booming business in 2010.

Overview:

The definition of a high-performance oscilloscope really is all about the customer's point of view. Two scopes may have the same bandwidth, number of channels, sampling rate, operating modes, and memory length. Yet, one will be bought instead of the other because its software or triggering capability or measurement suite better matches the customer's application requirements.

Overview:

The definition of a high-performance oscilloscope really is all about the customer's point of view. Two scopes may have the same bandwidth, number of channels, sampling rate, operating modes, and memory length. Yet, one will be bought instead of the other because its software or triggering capability or measurement suite better matches the customer's application requirements.

Looking for more information on our people, technology and solutions?


Contact Us
 
Top