Motor Surge Measurement with High Definition Oscilloscope

Download (229 KB)

Motor Surge Measurement with High Definition Oscilloscope

Issue:

The high-speed switching voltage of the inverter generates a high-voltage surge on the motor side, which can cause dielectric breakdown of the windings. Therefore, checking the motor surge voltage is an essential process in motor development and manufacturing. In recent years, as the efficiency of inverters using high-speed devices such as SiC has improved, the voltage and speed of motor surges have increased and the phenomenon has become more complex, requiring more accurate waveform analysis.

Solution:

The DLM5000HD equipped with a 12-bit ADC can simultaneously capture 8 channels of surges and related waveforms with high resolution, enabling more reliable and efficient surge voltage analysis.

Example: Observation of motor surge of SiC MOSFET_1

Example: Observation of motor surge of SiC MOSFET_2

Example: Observation of motor surge of SiC MOSFET

Related Industries

Related Products & Solutions

701927 Differential Probe 1400V / 150 MHz

  • 701927 Isolated Differential Probe
  • 150 MHz 
  • Max. Differential Voltage: ±1400 V (DC + ACpeak) at 500:1
  • Probe Power: dedicated probe interface For DLM, DL, and SB5000 series

701978 Differential Probe 1500 V / 150 MHz

  • 701978 Differential Probe for Oscilloscope 
  • 1500 V / 150 MHz
  • 500:1 / 50:1
  • Max. Differential Voltageļ¼š±1500 V (DC + ACpeak)

DLM3000HD Series High-Definition Oscilloscope

The DLM3000HD redefines high-definition in a compact design

  • 4 analog channels
  • 8-bit logic
  • Bandwidth: 350 or 500 MHz
  • Sample Rate: up to 2.5 GS/s
  • Vertical resolution: 12-bit
  • High resolution mode: up to 16-bit
  • Measurement memory: up to 1 GigaPoints
  • History waveforms: up to 200,000 triggers
  • Synchronization function for up to 8 analog channels
  • Logic and Serial Bus Analysis

DLM5000HD Series High-Definition Oscilloscope

The DLM5000HD series sets a new standard for high-definition oscilloscopes.

  • 4 or 8 analog channels
  • 16-bit logic + optional additional 16-bit logic
  • Bandwidth: 350 or 500 MHz
  • Sample Rate: up to 2.5 GS/s
  • Vertical resolution: 12 bit
  • High resolution mode: up to 16 bit
  • Measurement memory: up to 1 GigaPoints
  • History waveforms: up to 200,000 triggers
  • Synchronization function for up to 16 analog channels
  • Logic and Serial Bus Analysis

Mixed Signal Oscilloscopes

  • Yokogawa mixed signal oscilloscopes
  • Simultaneous, time correlated observations
  • Analysis of analog with digital (logic) signals
  • Troubleshooting electrical anomalies, measuring parametric values, monitoring signals

Oscilloscopes

  • Digital oscilloscopes
  • High-speed sampling
  • Range of bandwidths for electronic device design and development
  • Advantages of oscilloscope and multi-channel data recorder

Precision Making