ScopeCorder LITE SL1400 (DISCONTINUED)

Notice: This product was discontinued on Jun 10, 2014. See this replacement product:
ScopeCorder

The SL1400 ScopeCorder LITE is a plug-in module type chart recorder with a large built-in A4 sized high resolution thermal printer. It provides more simplified and intuitive, easy-to-use operational functions.

The SL1400 Scopecorder simplifies the process in all of your applications.

  • High sample rate: 10 MS/s
  • Data record Period: 100 µs to 30 days
  • A perfect fit for manufacturing and maintenance departments
  • Intuitive key names and menus for easy operation
  • Easily store data both on paper and in external memory media
  • Record data to USB or PC card devices or directly to the optional HDD
  • Up to 16 analog +16 logic inputs

Intuitive key names and menus for easy operation

Intuitive key names and menus for easy operation

Simple measurement set up

Store data in memory and print it in just three steps!

Sl1400 02

 

 

Long-term measurements with large capacity memory (50 MW total)

 

 

Long-term measurements with large capacity memory (50 MW total)

PDF output for printing A4-sized reports

Color PDF Output

When performing on-site measurements, you can print out the data and hand-write memos on the paper. Since the SL1400 simultaneously stores data to internal memory while printing, you can keep electronic and hard copy records with just a single action. (Remember that with thermal-sensible paper, it is vital to make photocopies for longterm preservation.) The SL1400 allows you to export results to files in PDF format, making it easy to save data for long periods of time, transfer the data to distant locations, or load them onto a PC. It is also easy to create reports since waveform data can be converted to an A4-size layout. Color PDF Output

 

Memory Backup Function

Sl1400 08 This function backs up about 150 hours of data saved to the acquisition memory immediately prior to power loss. Memory backup helps you avoid losing important data even if the power supply is unstable and gets cut off. (Backup time varies according to the usage environment. Four AA batteries are required for memory backup.)

 

 

 

 

 

Web Server Functions

 

Connect the SL1400 to your PC through the Ethernet connection. This allows for easy remote operation using Internet Explorer.

Sl1400 09

 

 

A Wide Range of Trigger Functions

Having a wide range of triggers is of course very useful for obtaining the desired waveforms. In addition, the GUI menu makes setting trigger conditions easy and intuitive.

 

 

 

Simple and Enhanced Triggers

 

Sl1400 10

Wave Window Trigger


Sl1400 11This function comes standard with the SL1400 and enable triggering on power supply waveforms. In addition to traditional power supply troubles, such as sudden outages, sags, and surges, you can make efficient real time observations of frequency fluctuations and voltage drops. This trigger activates when a signal exceeds the allowable values determined by comparing a defined waveform (wave window) with an actual waveform in real time.

Comparative waveforms can be automatically produced in real time based on measured waveforms. Detection on all 16 analog channels is available (with OR conditions).

 

 

Action-On Trigger (Automatically save measured data)

When this trigger is activated, the SL1400 performs a specified action each time a waveform is captured and displayed on the screen. This feature is useful for saving data automatically and reliably (e.g., for data collection in automated, continuous tests).

 

 

 

 

Manual Trigger (A trigger can be activated with press of a button)

 

 

Sl1400 16 With this feature, a trigger can be executed whenever you like, independent from the set trigger conditions.

Complete Connectivity

Sl1400 12

Internal 40 GB Hard Drive (/C8 Option)

Real-Time Hard Drive Recording

 

Sl1400 03

With the optional internal hard drive, you can record measurements to the hard drive in real time.
This makes it easy to manage and analyze data using a PC.

 

 

  • Maximum data capacity: 1GW
  • Maximum sampling rate: 100 kS/s
    • (Using 1 channel only)

 

 

 

 

 

 

 

Ethernet Interface (/C10 Option)

 

 

 

 

 

 

Connecting to a PC as a Web Server and FTP Server

Sl1400 04The SL1400 has a variety of server functions that let you perform remote controls or download waveform data and screen images onto a PC. You can also access the SL1400 using Internet Explorer. Same as with RS232 and GB-IB, you can write your own custom programs in Visual C++ 6.0 or Visual Basic 6.0 and control the SL1400 through an Ethernet interface.

 

 

 

 

 

Probe Power, 4-output (/P4 Option)

 

 

 Sl1400 05Probe power terminal for probe driving.

  • Maximum number of probes powerd : 4
  • Compatible probes :
    • Current probes 701933 (30 A) & 701930 (150 A)
  • Up to 2 current probes can be used at one time

 

 

 

 

 

 

 

 

 

 

 

 

 

701275 Acceleration & Voltage Input Module (w/AAF)

  • 2 channel Voltage Module/Acceleration Module
  • Anti-Aliasing Filter 
  • Direct input from built-in amp type acceleration sensor to measure acceleration 
  • DL350, DL850 series, DL950 and SL1000.

701251 Analog Voltage Input Module

  • 701251 Analog Input Module
  • High-Speed 1 Ms/s 16-Bit Isolation Module (2 ch)
  • High sensitivity range (10 mV), low noise (±100 µVtyp), high noise immunity
  • DL850, DL750, SL1000

701255 Analog Voltage Input Module

High-Speed 10 MS/s 12-Bit non-isolation Module (2 ch)
Non-Isolation version of model 720250
Applicable to DL350, DL850 series, DL950 and SL1000.

701265 High-Precision Temperature Input Module

Temperature/high-precision voltage Module (2 ch)
Thermocouple (K, E, J, T, L, U, N, R, S, B, W, iron-doped gold/chromel), high sensitivity range (1 mV), and low noise (±4 µVtyp)
Applicable to DL350, DL850 series, DL950 and SL1000.

701271 Strain Input Module (DSUB)

Strain Module with Shunt Calibration, type DSUB (2 channels) to be used in combination with 701957 or 701958 DSUB bridge head.
Using the strain module and strain gauge the ScopeCorder can detect and display mechanical stress (strain). It works on the principle that the resistance value of a metal foil changes as it expands and contracts.
Applicable to DL350, DL850 series, DL950 and SL1000.

701270 Strain Input Module (NDIS)

  • Strain Module, NDIS (2 channels)
  • 701955 or 701956 NDIS bridge head
  • Detect/display mechanical stress with ScopeCorder
  • DL350, DL850 series, DL950, SL1000

701262 Universal Voltage & Temperature Input Module (w/AAF)

  • Universal Module (with Anti-Aliasing Filter, 2 ch)
  • Thermocouple (K, E, J, T, L, U, N, R, S, B, W, iron-doped gold/chromel), with AAF
  • DL350, DL850 series, DL950 and SL1000

701261 Universal Voltage & Temperature Input Module

  • 701261 Universal Module (2 ch)
  • Thermocouple (K, E, J, T, L, U, N, R, S, B, W, iron-doped gold/chromel)
  • Applicable to DL350, DL850 series, DL950 and SL1000.

700929 Isolated Passive Probe 1000V / 100 MHz

  • Versatile 700929 passive oscilloscope probe
  • 100MHz frequency bandwidth
  • Isolated input module of ScopeCorder series
  • For use with isolated BNC inputs

701940 Passive Probe 600V / 10 MHz

  • 701940 Passive Probe
  • 10 MHz, 10:1/1:1, 600 V (DC + ACpeak) CAT II, 1.5 m
  • For ScopeCorder Non-Isolated Modules

701901 BNC to Safety Banana 1.8m Cable, 1:1

  • 701901 BNC to Safety Banana 1.8m Cable, 1:1
  • 1000 Vrms-CAT II, 1.8 m long
  • Safety BNC(male) to safety banana(female)
  • 701959, 701954, 758921, 758922, 758929

701954 Large Alligator Clip (dolphin type)

Set contains one black and one red clip.
1000 Vrms-CAT II.

366926 BNC to Alligator 1m Cable, 1:1

  • 1 m long BNC to alligator clip cable
  • Only for circuits with voltage levels no greater than 42 V
  • Applicable for DL750/DL750P, SL1000 & SL1400

758924 BNC to Banana Conversion Adapter

For conversion between BNC and female banana plug
Applicable for DL750/DL750P, SL1000 & SL1400.

701930 Current Probe 10 MHz / 150 ARMS

  • 701930 Current Probe 10 MHz / 150 ARMS
  • Powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply

701931 Current Probe 2 MHz / 500 ARMS

  • 701931 Current Probe 2 MHz / 500 ARMS
  • Powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply

701933 Current Probe 50 MHz / 30 ARMS

  • 701933 50 by 30 current probe
  • Powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply

701957/701958 D-Sub Bridge Heads 120Ω/350Ω

  • 701957 and 701958 D-SUB Bridge Head
  • Shunt calibration
  • 5m DSUB cable included
  • Bridge resistance:  120Ω 
  • Bridge resistance:  350Ω 

700924 Differential Probe 1400V / 100 MHz

  • Differential oscilloscope probe
  • 100 MHz
  • ±1400 V (DC + ACpeak) at 1000:1
  • Power: Internal battery or probe power supply
  • Works with Oscilloscopes, ScopeCorders

758921 Fork terminal adapter

  • 758921 Fork Terminal Adapters
  • For fitting a 4mm banana plug to a fork terminal
  • One black and one red clip
  • 1000 Vrms-CAT II

758929 Large Alligator Clip Adapter 1000V

  • Yokogawa 758929 Alligator Clip Adapter 
  • Rated at 1000V
  • Attaches to 758917 test leads
  • Sold in pairs black/red

700986 Logic Probe

8-bit, non-isolated, response speed: 1µs, threshold level approx 1.4V
Two measurement leads (B9879PX and B9879KX) included.

700987 Logic Probe - Isolated Inputs

  • 700987 Logic Probe - Isolated Inputs
  • 8-bit, isolated, response speed: 1ms or less (DC), 20ms or less (AC), threshold level 6VDC, or 50VAC.
  • 758917 and 758922, 758929, 701954 

366961 Banana to Alligator 1.2m Cable, 1:1

A subassembly of 1.2 m long test leads with alligator-clip adapters.
Use only for circuits having voltage levels no greater than 42 V.
Applicable for SL1000 & SL1400.

758917 DMM Measurement Lead Set

  • Set of 0.8m long red and black multimeter test leads
  • Used in combination with a pair of optional 758922 or 758929 alligator-clip adapters
  • 1000 Vrms, 32 Arms CAT II

701955/701956 NDIS Bridge Heads 120Ω/350Ω

  • ScopeCorder Accessories for DL850 series, DL750/DL750P, SL1000 & SL1400
  • 701955 NDIS Bridge Head, Bridge resistance: 120Ω , 5m NDIS cable included
  • 701956 NDIS Bridge Head, Bridge resistance: 350Ω , 5m NDIS cable included

701934 External Probe Power Supply

  • 701934 External Probe Power Supply
  • Power supply for current probes, FET probes, and differential probes
  • Supplies power for up to four probes, including large current probes

701902/701903 Safety BNC to BNC Cable 1m/2m

  • 701902/701903 Safety BNC to BNC Cable for oscilloscope
  • Safe, high-voltage measurements with DL350, DL950, and SL1000 isolated input modules 
  • 701902: 1000 Vtms-CAT II (BNC-BNC), 1 m
  • 701903: 1000 Vrms-CAT II (BNC-BNC), 2 m

758922 Small Alligator-Clip Adapter 300V

Rated at 300 V. Attaches to the 758917 test leads. Sold in pairs.

701966 Printer roll paper for DL750P and SL1400

  • Quality thermal printer paper for DL750P and the SL1400.
  • Paper width: 210 mm (A4 size)
  • Paper length: 20 m
  • Order Qty: 6 (1set)

Looking for more information on our people, technology and solutions?


연락처

Precision Making

Top