WE7000 PC-Based Measurement Instruments (DISCONTINUED)

Notice: This product was discontinued on Oct 30, 2013.

The WE7000 is Modular, High-speed, PC based data acquisition system thats exceeds most test application requirements. It provides multiple measuring instruments in a single system. It is easily scalable and expandable. Its modular design facilitates easy configuration and traceability. Since it is a PC based system, it comes with its own out of the box, ready to use and Windows based standard control software. The standard control software allows you to both control and acquire data from the instruments via USB or Ethernet communication interfaces. It supports both streaming and triggered applications. The modules have large built-in memory to support long capture times at high sample rates.

This item is only available in the United States,
the United Kingdom, Germany, France,
the Netherlands, Spain, Italy, South Korea,
Australia, and Japan.

Main Features Include

Modular Design for Easy Operation

  • Multiple Measuring Instruments in a Single System
  • Modular Design for Easy Configuration
  • Easy Expansion and Modification
  • High Precision Modules with Traceability

Modules for a Variety of Signals and Extensive Features

 

  • Covers Various Applications from a DC to 20MS/s
  • Simultaneous Multi-Channel Measurement
  • Source & Measure
  • Arbitrarily Link or Combine Modules

Easily Control All Modules Using the Windows Based Standard Control Software

 

 

  • Versatile Data Display Features
  • Group Multiple Channels & Switch Display between Groups
  • Save Data with Complete Control
  • Perform Computation and Post Analysis

 

Overview:

Even though the correct USB drivers have been installed, and the device displays correctly in the Windows Device Manager Window, the High-Speed Data Acquisition Unit SL1000 Acquisition Software fails to detect the SL1000 main unit. Solutions: Verify ...

Overview:

Yes, you can perform waveform calculations in real time through the 707702 Computation Function Setup Software. y creating arithmetic expressions, you can perform calculations with the 4 basic arithmetic operators, ...

Overview:

Microsoft(R) Excel 97 and 2000 only.

Overview:

Within the protocol system, TCP and UDP (short for "User Datagram Protocol" which puts a priority on high-speed) both occupy the high rank of IP, but differ in use and function. Generally speaking, however, when we use ...

Overview:

The optical interface cards and modules for the WE7031/WE7032/WE7033/WE7034 instruments and the new modules for the WE7035/WE7036/WE7037/WE7038 including cables, are cross compatible.

Overview:

Yokogawa offers the PCI and ISA bus cards, and within each of those there are 1-port and 2-port types.

Overview:

Connection made by a cross cable does not comply with Ethernet standards. For reliable data communications, please use a hub when you want to make a direct connection to a PC.

Overview:

Yes, you can bypass the router (subnet) and connect using the WE7000 control software ver. 4 and later. However, this is limited to the WE7052 Fast Ethernet module.

Overview:

Yes, you can use the WE7051 Ethernet module (10Base-T) and the WE7052 Fast Ethernet module (100Base-TX/10Base-T) together.

Overview:

Yes, the WE7052 Fast Ethernet module supports DHCP. However, you must have the WE7000 control software ver. 4 or later.

Overview:

The WE7052 Fast Ethernet module supports automatic selection (AUTO NEGOTIATION) of communication speed and communication method. Manual setting is possible for connecting with an instrument that doesn't have the AUTO ...

Overview:

Yes, you can use a 100Base-TX/10Base-T with the WE7052 Fast Ethernet Module.

Overview:

The output connectors are different. The WE7281 has a clamp type terminal, and the WE7282 has a BNC terminal. Also, the maximum common mode voltage, and maximum voltage between channels etc. vary in their specifications ...

Overview:

The input connectors are different, the WE7271 Digitizer Module has a clamp type terminal, and the WE7272 Digitizer Module has a BNC terminal. Also, the maximum common mode voltage and maximum voltage between channels vary in their specifications ...

Overview:

Contact input/output is possible using the WE7262 32-bit Digital input/output module's 707823/707824 16-bit Digital input/output terminal box.

Overview:

The update cycle changes depending on the acquisition mode and the gate time during frequency measurement. When the acquisition mode is One Shot, the update cycle is approximately 0.5-1 seconds. However for frequency ...

Overview:

For high-speed data recording in trigger mode/gate mode, the digitizer module is equipped with internal memory to store measurement data in order to record reliable data without receiving any effects of the load ...

Overview:

Yes, there is a software called the 707751 Arbitrary Waveform Editor. You can create waveforms using the editor's standard functions or with the mouse. You can read in files created in CSV, or in Yokogawa's proprietary ...

Overview:

You can select whether to save files in binary (WVF format) or ASCII (CSV format). WVF is Yokogawa's proprietary format. CSV format can be read by popular spreadsheet programs.

Overview:

You can express any arbitrary exponentiation, in Xviewer or DL series instruments, by using the LOG (common logarithm) and EXP (exponential) functions. For example, for C1 raised to the exponent of 0.2, the math ...

Overview:

The Gage Factor setting for the 701271 Strain Input Module can be directly inputted within the range of 1.90 to 2.20. However, it is possible to indirectly set the Gage Factor to a larger value by setting the constant ...

Overview:
  • Xviewer can open multiple files from different DL, SL, and WE series instruments into a single window display 
  • Same sample rate, trigger position, record length
Overview:

Yes you can load the setup files *.WES that was saved using the older version of the WE Control Software onto the newer version of the WE Control Software. Please follow the procedures listed in the attached PDF file.

Overview:

One possible solution is to use a third party 10:1 attenuator such as the one shown in the attached document. You may use the attenuator to allow the direct input of higher voltage levels with the 701262 module, since ...

Overview:

To perform a shunt calibration using the 701271 strain gage module and the ScopeCorder, please complete the following procedures: Connect the strain module 701271, bridge head 701957/701958 and the strain ...

Overview:

In free run mode, the execution timing is different depending on the type of computation. In the case of computations such as FFT, Filter, pulse width, etc. various data are arranged in a chronological direction.

Overview:

With either the WE7141 100 MHz universal counter module or the WE7261/WE7262 32-bit digital I/O module, if you are performing continuous measurements with more than three of the same modules you must set the sampling ...

Overview:

The external trigger input (TRIG IN) as well as external input/output (EXT. I/O) trigger signal becomes the level signal. The WE7251/WE7271 digitizer module will detect the bus trigger by that level. As long as the ...

Overview:

The minimum record length which can be input is limited such that "record length x sampling interval" must be 5 milliseconds or more. When you set the record length to a value smaller than this it automatically changes ...

Overview:

You must wait at least five seconds after turning the power switch to the measuring instrument OFF before turning it back ON again. If you wait less than five seconds, there is a possibility for a malfunction to occur ...

Overview:

Yes, however the communication drivers are different so you will need a new driver for the WE7035/WE7036 optical interface card. The driver is located on the WE7000 Control Software CD ROM Ver. 3.1.2 and later or you ...

Overview:

If you wish to install a fiber optic card in a PC with a lack of available IRQs, you can reserve a PCI slot in the PC BIOS which frees up an IRQ and allows you to use the card. However, this method may not work on all ...

Overview:

You must wait at least five seconds after turning the main power switch OFF before turning it back ON again. Please do not switch the power OFF and ON in less than 5 seconds.

Overview:

After entering the communications settings with serial communications, use the main power switch on the back of the measuring instrument to perform a power cycle. Also, in the MS DOS prompt window, try executing the ...

Overview:

If you are using serial communication or ethernet to connect the WE7000 Control Software to the PC, it is necessary to create a shortcut with a start option added to the end of the shortcut target. For WE control ...

Overview:

To use the waveform parameter Measure function or the computation Math function, you need the 707702 Computation Function Setup Software. In the case of the WE7111 Digital Oscilloscope Module, you can perform waveform parameter automatic ...

Overview:

Yes, AC coupling is supported with the WE7275 2-CH, 1 MS/s Isolated digitizer module.

Overview:

The WE7275 2-CH, 1 MS/s isolated digitizer module comes with an up-to-40 kHz anti-aliasing filter. Also, each digitizer module (WE7275/WE7271/WE7272/WE7251/WE7245) includes a low-pass filter. The cut-off frequency ...

Overview:

The sampling interval changes with the type of time base and the number of measurement channels per module. There are two possible methods:  If Time base = internal Number of channels : 1-2 = 0.2 s, 3-5 = 0.3 s, 6-7 ...

Overview:

You must use a probe with a attenuator of "10:1", otherwise the self test will not run correctly. Also, before executing the self-test, please allow for a 30 minutes warm-up time. If the instrument does not warm up, the ...

Overview:

The AC Power Input in all Yokogawa instruments is designed as a 3-pin connection (one of which is a GND pin). In some parts of the world, PCs are sold with AC power cables that are 2-pin. Often times this means the ...

Overview:

When using the Adjustment Software to adjust a WE7000 Pc Based Measurement Instruments input module, the module should be installed in slot 2 of the main station. The slot labels on the WE Main Station begin with "0". Therefore, install the module in ...

Overview:

High Resolution mode can be used to remove high frequency noise and increase vertical resolution. It achieves this by increasing the number of effective bits per data to 12-bits through digital and bandwidth filters.

Overview:

A Non-contact thermometer receives infrared rays without touching an object and measures the temperature by converting the amount of infrared rays. The object will radiate infrared rays from its surface (radiant ...

Overview:

In order to analyze the harmonics by the PLL synchronization, the maximum possible window width is automatically determined depending on the frequency of the fundamental wave of the input signal (fundamental frequency ...

Overview:

The following WE7000 modules have a issued calibration certificate: 707111/HE 100 MS/s Digital Oscilloscope Module 707121/HE 10 MHz Function Generator Module 707141/HE 10 Universal Counter Module 707241/HE 10-Ch, ...

Overview:

The warranty period is 1 year for the main instrument, modules, and cards (accessories are not covered by warranty). In the unlikely event that a device should fail during the warranty period, repair will be provided ...

Overview:

Yes, you can detect the trigger conditions of the input signal with the module, output the result once to the trigger bus of the measuring station, then send back the result from the OR and AND operation once more to ...

Overview:

You can perform continuous measurement using the digitizer module's Free Run mode. However, data transmission speeds are limited. Please consult your sales representative for details. They can tell you whether data ...

Overview:

Yes, you can set the range for each channel.

Overview:

The WE7241 digital temperature measurement module can measure up to ±50V. The WE7271/WE7272 4-CH, 100 kS/s Isolation digitizer module up to ±35V. The WE7275 2-CH, 1 MS/s Digitizer module accepts up to ±350V.

Overview:

Simultaneous measurement is possible by making use of the station's internal arming signal. The lag in start timing between each module would be 10 ms or less. (Some modules do not allow connection to the arming signal.)

Overview:

The lag time from the external terminal to the bus trigger / time base is as follows:When inputting from TRIG IN:TRIG IN -> bus trigger signal : 40 ns (typical value)TRIG IN -> time base signal : 25 ns (typical ...

Overview:
At present, a separate DC/AC inverter is required. In case of the WE800 measurement station (eight slots), it has a maximum power consumption of 550VA.
Modes d'emploi
Spécifications de produits
Software

Looking for more information on our people, technology and solutions?


Contact Us

Precision Making

Top