MT210/MT210F DIGITAL MANOMETERS

The MT210/210F series of digital manometers, produced by combining YOKOGAWA's best pressure measurement technologies, offers excellent accuracy, reliable operation, and a variety of applications. These measuring tools provide the perfect solutions for a wide range of technologies.
page links
Details
Features
Offering Precision Digital and Fast Response Digital Manometer options with:
- High accuracy:
- A wide range of pressures:
- Three measurement modes:
- Options:
GP-IB and RS-232 interfaces, l12-V DC power supply, lBattery operation (optional)
High performance and reliable operation
- High performance, high resolution
The MT210/210F series features high performance, and a high, basic accuracy of ±0.01% thanks to the YOKOGAWA-original silicon resonant sensor. - High allowable input pressure
The maximum allowable input pressure is as high as 500 kPa (such as in the 130 kPa-range model). Now you don't have to worry about sensor breakdown due to overrange pressure input.
- Traceable to Japanese national standards
- Minimal effect of temperature changes
The silicon resonant sensor is highly immune to environmental discrepancies such as temperature changes. - A variety of measurement objectives
- Supports high-speed measurement
The MT210F series has been added to our range or pressure measuring instruments in order to support high-speed measurements. These measurements, such as the observation of transient-response characteristics, include relatively fast pressure changes. - A wide range of models
You can choose a model to fit your application from models with different pressure types/gauges and absolute and differential pressures. Also choose among models with pressure ranges from the low differential pressure of 1 kPa to the gauge pressure of 3000 kPa. - Applicable to both gases and liquids Never be bothered by the labor of switching between models. The MT210/210F series can measure both gases and liquids. With the new differential-pressure models you can measure liquids that you couldn't measure before with the MT110-series differential-pressure models.
- Supports high-speed measurement
- Ease of systemization
- D/A conversion output The D/A-converted signal of a measured value is output through an external terminal. This feature permits you to easily send data to your measurement system or recorder
Observation examples of D/A conversation output
- Differences due to the measurement mode, where the normal-speed waveform is when the Moving-average option is turned off

- Close-up of output waveform (with the dynamic mode enabled)

- Differences due to the measurement mode, where the normal-speed waveform is when the Moving-average option is turned off
- Comparator output and external trigger input Use these I/O functions to set the upper and lower limits, judge the measured value, and output the result through an external terminal. What's more, you can apply a start-of-measurement trigger using a falling edge of an external trigger signal. These features will help automate your production/inspection lines of pressure-related products.
- GP-IB and RS-232 interfaces This feature lets you read measured values into your PC or set measurement conditions from the PC. Communication is still possible even when the MT210/210F series are operated on batteries or the DC power source.
- D/A conversion output The D/A-converted signal of a measured value is output through an external terminal. This feature permits you to easily send data to your measurement system or recorder
- Support of field use
- 12-V DC power supply
The MT210/210F operate on a 12-V DC power supply. This feature is useful for in-vehicle tests. - Operation on Ni-Cd battery packOperation on Ni-Cd battery pack The MT210/210F series, which come standard with a built-in battery charger, can continuously operate on an optional Ni-Cd battery pack for approximately 10 hours.
- 12-V DC power supply
Assured compatibility with earlier models
- Inheritance of performance from MT110 Series
The MT210/210F series feature additional functions such as support of high-speed measurement, while inheriting the basic performance from their predecessor, the MT110. - Common communication commands
The MT210/210F series share the GP-IB and RS-232 communication protocols with their predecessor, the MT110. No modifications to the communication protocols are necessary when expanding a system that uses the earlier series or when replacing the series.
Front Panel (differential-pressure model, JPG, 30 KB)
Rear Panel (differential-pressure model, JPG, 27 KB)
| Phototelectric Element | Silicon Photodiode |
| Measuring Range | 0.0 to 99.9/999/9990/99900/999000 lx |
| Response Time | 2 sec (manual range) 5 sec (auto rang) |
| Accuracy | ±4% rdg ±1 dgt |
| External Dimensions | Approx. 67 (W) × 177 (H) × 38 (D) mm |
| Approx. Weight | 260 g |
| Power | One 6F22 (S-006P) 9 V dry battery or AC adapter (Option) |
| Accessories | 3 Meter Data Output Cable for Light Meter (#910-03) 3 Meter Extension Cable for Light Meter (#910-02) AC Convertor (#94001) AC Convertor (#B96466N) RS232C Convertor (not isolated battery) (#95001) Soft Case (510 02/03) (#RB037A) |
스펙
| 이름 | 설명 | 파일 유형 | |
|---|---|---|---|
| Bulletin 7673-00E | Series of Digital Manometers MT210/MT210F | 391 KB |
다운로드 |
리뷰
Hirai Co., Ltd. System Division Laboratory
"The MT210 really stood out for us because it excels at pressure
measurement which is the key to effective gas flow measurement."
The Hirai Co., Ltd. System Division Laboratory Chooses the MT Series
![]() Hirai Co., Ltd. System Division Laboratory From upper right: Executive Technical Advisor: Mr. Masao Hayakawa Chief Engineer: Mr. Toru Hirayama From lower left: Laboratory Manager: Mr. Takeshi Yakuwa Mr. Hiroshi Asano and Mr. Nobuomi Kizami |
As an JCSS(Japan Calibration Service System) Accredited
Laboratory, our technology lab performs calibration of small gas flow
rates based on Measurement Law, as well as R&D and sales of such
things as gas small flow rate standards and calibration equipment. Eight years ago we began research in conjunction with The National Metrology Institute of Japan(NMIJ) in the Ministry of Economy, Trade and Industry, as a national standard laboratory in Japan, with the goal of establishing standards for extremely small flow rates of gases (about 40cc to 150L/min.). We were searching for a good standard that reflected the "uncertainty" (an estimate of the range of existing true values). The measurement of gas flow rate involves determining the values of many variables such as absolute pressure and temperature, and certain other characteristics of the gas. This is extremely difficult, so pressure measurement is especially important. Pressure measurement is the key to gas flow rate measurement, so a good manometer is required, and while we were investigating makers domestically and abroad we discovered YOKOGAWA's MT series of digital manometers. |
The
MT series can confirm whether the noise and irregular values from
several years worth of stored data are sufficiently stable, so for
precise measurement of absolute pressure, it has many uses not only at
this laboratory but also at the NMIJ.Also, the YOKOGAWA pressure sensor is of course used for the secondary standards for establishing a national flow rate standard, and for our use as an authorized representative, but furthermore is used for practical customer-specific standards developed by our company.
Using our lab's internal pressure standard, a Air Piston Gauge, we calibrate the pressure sensors included in YOKOGAWA's MT series one by one, one time every 6 months. We started with an "uncertainty" in the 350 kPa (kilopascals) pressure range, but finally we could achieve the very excellent result of under 10 Pa, so now we measure with confidence. The fact that we can maintain an uncertainty coming from the repeatability in our company's specified second order standard of 0.04% or less is due to the YOKOGAWA MT series and the pressure sensor.
![]() Hirai's Product MFC Calibration System |
The MFC calibration system is an instruments used for flow rate
calibration and investigations of the characteristics of flow rate
meters simply and with high precision. Since we're using sonic Venturi
nozzles mass/flow rate control systems for flow rate standards, we can
calibrate a gas flow rate at an uncertainty from the national standard
and traceability |
![]() Award Winners |
Hirai was awarded the Daily Industrial/Asahi Small Business
Promotion Foundation's 13th annual "Small Business Excellence in New
Technology and Products" award in April, 2000. |