Analog Insulation Testers 3213A Series (DISCONTINUED)

Notice: This product was discontinued on Mar 31, 2017. See this replacement product:

The 3213A Series Analog Insulation Tester provides a one-touch press-and-lock switch for continuous measurement of insulation of electric equipment or circuits. This single rating insulation tester is a portable handheld device with a vibration and shock resistant design.

Specifications - Model 321341

Rating 100V/20MΩ
Effective Measuring Range 0.02–20MΩ
Central Scale Value 0.5MΩ
AC Voltage Measurement 0 to 150 V
Lower Limit 0.1MΩ
Rated Current 1 mA
Scale Length 88 mm
Approx. Width 110 mm
Approx. Height 180 mm
Approx. Depth 60 mm
Approx. Weight 700 g
1.2 kg
Batteries Eight AA (R6P) batteries
Standard Accessories Batteries Qty - 8
Handle (B9303XE) Qty - 1
Hard case (B9600HA) Qty - 1 (with leads-housing case)
Test lead (B9205VA) Qty - 1 (consist of earth/line terminal)
User's manual Qty - 1

 

Standard Test Conditions - Model 321341

 

Ambient Temperature/Humidity Ranges 23 ±5 /45-75% RH
Position of Use Horizontal (5° max. of angle of inclination)
Battery Voltage Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)
Tolerance Mentioned Conditions Resistance measurement: First effective measuring range = ±5% of reading
Second effective measuring range = ±10% of reading
Infinite and zero scale values: 0.7% max. of scale length
AC voltage: ±10% of maximum scale value
No-load voltage: 130% max. of rated voltage
Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range
Short-circuit current: 12 mA max.

 

Specifications - Model 321342

 

Rating 250V/50MΩ
Effective Measuring Range 0.05–50MΩ
Central Scale Value 1MΩ
AC Voltage Measurement 0 to 250 V
Lower Limit 0.25MΩ
Rated Current 1 mA
Scale Length 88 mm
Approx. Width 110 mm
Approx. Height 180 mm
Approx. Depth 60 mm
Approx. Weight 700 g
1.2 kg
Batteries Eight AA (R6P) batteries
Standard Accessories Batteries Qty - 8
Handle (B9303XE) Qty - 1
Hard case (B9600HA) Qty - 1 (with leads-housing case)
Test lead (B9205VA) Qty - 1 (consist of earth/line terminal)
User's manual Qty - 1

 

Standard Test Conditions - Model 321342

 

Ambient Temperature/Humidity Ranges 23 ±5 /45-75% RH
Position of Use Horizontal (5° max. of angle of inclination)
Battery Voltage Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)
Tolerance Mentioned Conditions Resistance measurement: First effective measuring range = ±5% of reading
Second effective measuring range = ±10% of reading
Infinite and zero scale values: 0.7% max. of scale length
AC voltage: ±10% of maximum scale value
No-load voltage: 130% max. of rated voltage
Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range
Short-circuit current: 12 mA max.

 

Specifications - Model 321343

 

Rating 500V/100MΩ
Effective Measuring Range 0.1–100MΩ
Central Scale Value 2MΩ
AC Voltage Measurement 0 to 300 V
Lower Limit 0.5MΩ
Rated Current 1 mA
Scale Length 88 mm
Approx. Width 110 mm
Approx. Height 180 mm
Approx. Depth 60 mm
Approx. Weight 700 g
1.2 kg
Batteries Eight AA (R6P) batteries
Standard Accessories Batteries Qty - 8
Handle (B9303XE) Qty - 1
Hard case (B9600HA) Qty - 1 (with leads-housing case)
Test lead (B9205VA) Qty - 1 (consist of earth/line terminal)
User's manual Qty - 1

 

Standard Test Conditions - Model 312343

 

Ambient Temperature/Humidity Ranges 23 ±5 /45-75% RH
Position of Use Horizontal (5° max. of angle of inclination)
Battery Voltage Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)
Tolerance Mentioned Conditions Resistance measurement: First effective measuring range = ±5% of reading
Second effective measuring range = ±10% of reading
Infinite and zero scale values: 0.7% max. of scale length
AC voltage: ±10% of maximum scale value
No-load voltage: 130% max. of rated voltage
Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range
Short-circuit current: 12 mA max.

 

Specifications - Model 321344

 

Rating 500V/1000MΩ
Effective Measuring Range 1–1000MΩ
Central Scale Value 20MΩ
AC Voltage Measurement 0 to 300 V
Lower Limit 0.5MΩ
Rated Current 1 mA
Scale Length 88 mm
Approx. Width 110 mm
Approx. Height 180 mm
Approx. Depth 60 mm
Approx. Weight 700 g
1.2 kg
Batteries Eight AA (R6P) batteries
Standard Accessories Batteries Qty - 8
Handle (B9303XE) Qty - 1
Hard case (B9600HA) Qty - 1 (with leads-housing case)
Test lead (B9205VA) Qty - 1 (consist of earth/line terminal)
User's manual Qty - 1

 

Standard Test Conditions - Model 321344

 

Ambient Temperature/Humidity Ranges 23 ±5 /45-75% RH
Position of Use Horizontal (5° max. of angle of inclination)
Battery Voltage Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)
Tolerance Mentioned Conditions Resistance measurement: First effective measuring range = ±5% of reading
Second effective measuring range = ±10% of reading
Infinite and zero scale values: 0.7% max. of scale length
AC voltage: ±10% of maximum scale value
No-load voltage: 130% max. of rated voltage
Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range
Short-circuit current: 12 mA max.

 

Specifications - Model 321345

 

Rating 1000V/2000MΩ
Effective Measuring Range 2–2000MΩ
Central Scale Value 50MΩ
AC Voltage Measurement 0 to 300 V
Lower Limit 1MΩ
Rated Current 1 mA
Scale Length 88 mm
Approx. Width 110 mm
Approx. Height 180 mm
Approx. Depth 60 mm
Approx. Weight 700 g
1.2 kg
Batteries Eight AA (R6P) batteries
Standard Accessories Batteries Qty - 8
Handle (B9303XE) Qty - 1
Hard case (B9600HA) Qty - 1 (with leads-housing case)
Test lead (B9205VA) Qty - 1 (consist of earth/line terminal)
User's manual Qty - 1

 

Standard Test Conditions - Model 321345

 

Ambient Temperature/Humidity Ranges 23 ±5 /45-75% RH
Position of Use Horizontal (5° max. of angle of inclination)
Battery Voltage Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)
Tolerance Mentioned Conditions Resistance measurement: First effective measuring range = ±5% of reading
Second effective measuring range = ±10% of reading
Infinite and zero scale values: 0.7% max. of scale length
AC voltage: ±10% of maximum scale value
No-load voltage: 130% max. of rated voltage
Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range
Short-circuit current: 12 mA max.
Model Description
321341 Rating 100V/20MΩ; Effective Measuring Range 0.02–20MΩ; Central Scale Value 0.5MΩ; AC Voltage Measurement 0 to 150 V; Lower Limit 0.1MΩ; Rated Current 1 mA
321342 Rating 250V/50MΩ; Effective Measuring Range 0.05-50MΩ; Central Scale Value 1MΩ; AC Voltage Measurement 0 to 250 V; Lower Limit 0.25MΩ; Rated Current 1 mA
321343 Rating 500V/100MΩ; Effective Measuring Range 0.1–100MΩ; Central Scale Value 2MΩ; AC Voltage Measurement 0 to 300 V; Lower Limit 0.5MΩ; Rated Current 1 mA
321344 Rating 500V/1000MΩ; Effective Measuring Range 1–1000MΩ; Central Scale Value 20MΩ; AC Voltage Measurement 0 to 300 V; Lower Limit 0.5MΩ; Rated Current 1 mA
321345 Rating 1000V/2000MΩ; Effective Measuring Range 2–2000MΩ; Central Scale Value 50MΩ; AC Voltage Measurement 0 to 300 V; Lower Limit 1MΩ; Rated Current 1 mA
설명서

Looking for more information on our people, technology and solutions?


연락처

Precision Making

Top