Ripple Noise Measurement with High Definition Oscilloscope

Download (244 KB)

Ripple Noise Measurement with High Definition Oscilloscope

Issue:

Ripple noise observation of a switching power supply is usually performed with AC coupling, but there may be times when you want to see the waveform including DC, such as when the output fluctuates greatly. At that time, conventional 8-bit oscilloscopes do not have sufficient resolution, making it difficult to capture noise. Some operators overdrive the waveform to capture it, but be careful as it distorts the waveform and makes it impossible to measure accurately.

Solution:

The DLM5000HD with 12-bit ADC has 16 times the vertical resolution compared to 8-bit oscilloscopes, making it ideal for such measurements. Also, a record length of up to 1 G points enables long time measurements at high sample rates.

Switching power supply output element overview

Switching power supply output element overview

Observation of ripple noise (BW 100MHz, high-res mode)

Observation of ripple noise (BW 100MHz, high-res mode)

Switching noise can be identified even in waveforms taken with DC coupling.

Related Industries

Related Products & Solutions

701927 Differential Probe 1400V / 150 MHz

  • 701927 Isolated Differential Probe
  • 150 MHz 
  • Max. Differential Voltage: ±1400 V (DC + ACpeak) at 500:1
  • Probe Power: dedicated probe interface For DLM, DL, and SB5000 series

701978 Differential Probe 1500 V / 150 MHz

  • 701978 Differential Probe for Oscilloscope 
  • 1500 V / 150 MHz
  • 500:1 / 50:1
  • Max. Differential Voltageļ¼š±1500 V (DC + ACpeak)

DLM3000HD Series High-Definition Oscilloscope

The DLM3000HD redefines high-definition in a compact design

  • 4 analog channels
  • 8-bit logic
  • Bandwidth: 350 or 500 MHz
  • Sample Rate: up to 2.5 GS/s
  • Vertical resolution: 12-bit
  • High resolution mode: up to 16-bit
  • Measurement memory: up to 1 GigaPoints
  • History waveforms: up to 200,000 triggers
  • Synchronization function for up to 8 analog channels
  • Logic and Serial Bus Analysis

DLM5000HD Series High-Definition Oscilloscope

The DLM5000HD series sets a new standard for high-definition oscilloscopes.

  • 4 or 8 analog channels
  • 16-bit logic + optional additional 16-bit logic
  • Bandwidth: 350 or 500 MHz
  • Sample Rate: up to 2.5 GS/s
  • Vertical resolution: 12 bit
  • High resolution mode: up to 16 bit
  • Measurement memory: up to 1 GigaPoints
  • History waveforms: up to 200,000 triggers
  • Synchronization function for up to 16 analog channels
  • Logic and Serial Bus Analysis

Mixed Signal Oscilloscopes

  • Yokogawa mixed signal oscilloscopes
  • Simultaneous, time correlated observations
  • Analysis of analog with digital (logic) signals
  • Troubleshooting electrical anomalies, measuring parametric values, monitoring signals

Oscilloscopes

  • Digital oscilloscopes
  • High-speed sampling
  • Range of bandwidths for electronic device design and development
  • Advantages of oscilloscope and multi-channel data recorder

Precision Making