Ripple Noise Measurement with High Definition Oscilloscope

Download (244 KB)

Ripple Noise Measurement with High Definition Oscilloscope

Issue:

Ripple noise observation of a switching power supply is usually performed with AC coupling, but there may be times when you want to see the waveform including DC, such as when the output fluctuates greatly. At that time, conventional 8-bit oscilloscopes do not have sufficient resolution, making it difficult to capture noise. Some operators overdrive the waveform to capture it, but be careful as it distorts the waveform and makes it impossible to measure accurately.

Solution:

The DLM5000HD with 12-bit ADC has 16 times the vertical resolution compared to 8-bit oscilloscopes, making it ideal for such measurements. Also, a record length of up to 1 G points enables long time measurements at high sample rates.

Switching power supply output element overview

Switching power supply output element overview

Observation of ripple noise (BW 100MHz, high-res mode)

Observation of ripple noise (BW 100MHz, high-res mode)

Switching noise can be identified even in waveforms taken with DC coupling.

Related Industries

Related Products & Solutions

701927 Differential Probe 1400V / 150 MHz

  • 701927 Isolated Differential Probe
  • 150 MHz 
  • Max. Differential Voltage: ±1400 V (DC + ACpeak) at 500:1
  • Probe Power: dedicated probe interface For DLM, DL, and SB5000 series

701978 Differential Probe 1500 V / 150 MHz

  • 701978 Differential Probe for Oscilloscope 
  • 1500 V / 150 MHz
  • 500:1 / 50:1
  • Max. Differential Voltageļ¼š±1500 V (DC + ACpeak)

Precision Making

Top