Voltage Probes

Enhance Measurement Precision with Yokogawa's Advanced Voltage Probes

An oscilloscope's performance heavily relies on the quality of its probes. Yokogawa offers a comprehensive range of voltage probes, including high voltage scope probes, differential probes, active probes, low capacitance probes, and passive types. Our voltage probes cater to a wide range of applications with capabilities up to 7kV and frequency bandwidths reaching 5 GHz.

Key Features of Yokogawa Voltage Probes

Yokogawa's voltage probes are designed to meet the highest standards of precision and reliability:

  • High Voltage Scope Probes: Suitable for measuring high voltage signals with accuracy.
  • Differential Probes: Ideal for measuring between two points in a circuit.
  • Active Probes: Provide high-frequency performance with minimal loading.
  • Low Capacitance Probes: Ensure minimal interference with the circuit being measured.
  • Passive Probes: Robust and versatile for general-purpose measurements.

Applications of Voltage Probes

Yokogawa's voltage probes are used across various industries for diverse applications, including:

  • Oscilloscope Measurements: Ensuring precise and reliable data collection in high-frequency environments.
  • High Voltage Testing: Safe and accurate measurement of high voltage signals.
  • Differential Measurements: Accurate signal measurement between two circuit points.

Advantages of Yokogawa Voltage Probes

Yokogawa's voltage probes offer several benefits, making them the preferred choice for professionals:

  • Wide Range of Options: From high voltage to differential and active probes.
  • High Accuracy and Reliability: Ensure precise measurements every time.
  • Durable and Robust Design: Built to withstand rigorous use in various environments.

Equip your oscilloscopes with Yokogawa's advanced voltage probes to enhance your measurement precision and reliability.

  • 701924 Differential Probe
  • 1 GHz, 50:1, Max. Differential Voltage: ±25 V (DC + ACpeak), Probe Power: dedicated probe interface

500 MHz, 50:1, Max. Differential Voltage:±25 V(DC+ACpeak)
Probe Power:Dedicated probe interface

  • Wide-bandwidth high-voltage differential probe
  • 400 MHz bandwidth
  • Max. differential voltage: ±1000V (DC + ACpeak) at 500:1
  • Probe power: Dedicated probe interface for DLM3000, DLM3000HD, DLM5000, DLM5000HD
  • Wide-bandwidth high-voltage differential probe
  • 400 MHz bandwidth 
  • Max. differential voltage: ±2000V (DC + ACpeak) at 1000:1
  • Probe power: Dedicated probe interface for DLM3000, DLM3000HD, DLM5000, DLM5000HD
  • 701927 Isolated Differential Probe
  • 150 MHz 
  • Max. Differential Voltage: ±1400 V (DC + ACpeak) at 500:1
  • Probe Power: dedicated probe interface For DLM, DL, and SB5000 series
  • 701977 Differential Probe for Oscilloscope 7000 V / 50 MHz
  • 50 MHz, 1000:1 / 100:1, Max.
  • Differential Voltage: 5000 Vrms and 7000 Vpeak or less
  • 701978 Differential Probe for Oscilloscope 
  • 1500 V / 150 MHz
  • 500:1 / 50:1
  • Max. Differential Voltage:±1500 V (DC + ACpeak)

500 MHz, 10:1, 600 V (DC + ACpeak) CAT II, 1.3 m Supplied standard with DLM3000, DLM5000, DLM5000HD series

  • 701938 Passive Probe
  • 200 MHz, 10:1, 600 V (DC + ACpeak) CAT II, 1.5 m
  • For DLM2000 (200 MHz model)
  • 701939 Passive Probe 600V / 500 MHz
  • 500 MHz, 10:1, 600 V (DC + ACpeak) CAT II, 1.3 m
  • For DLM2000, DLM4000, DL6000, DLM6000 series
  • 701940 Passive Probe
  • 10 MHz, 10:1/1:1, 600 V (DC + ACpeak) CAT II, 1.5 m
  • For ScopeCorder Non-Isolated Modules

400 MHz, 10:1/1:1, 600 V (DC + ACpeak) or 424 Vrms CAT II, 1.5 m
For DL9000, DL9700/DL9500, SB5000 series

500 MHz, 10:1, 400 Vrms/1250 Vpeak CAT O 300 Vrms CAT II, 1.2 m
For DLM2000, DLM4000, DL6000, DLM6000 series

500 MHz, 10:1, 400 Vrms, 1.3 m
For DLM3000, DLM5000, DLM5000HD series

  • 701944 High Voltage Passive Probe 1000Vrms / 400 MHz
  • For DL1700, DLM2000-6000, DL6000, DL9000, SB5000 series
  • 3m High Voltage Probe (oscilloscope)
  • DC to 250 MHz bandwidth 
  • 100:1 attenuation 
  • Max Input 1000 Vrms CAT II 4000 V transient over-voltage CAT O

200 MHz, 10:1, ±1000 V (DC + ACpeak) CAT II, 2.5 m,Wide operating temperature range (−40 to +85°C)
For DLM2000, DLM4000 series.

200 MHz, 10:1, ±1000V (DC + ACpeak) CAT II, 2.5 m
Operating environment: −40 to +85°C (no condensation)
For DLM3000, DLM5000, DLM5000HD series.

  • Versatile 700929 passive oscilloscope probe
  • 100MHz frequency bandwidth
  • Isolated input module of ScopeCorder series
  • For use with isolated BNC inputs
  • 1.5m Isolated Probe (ScopeCorder)
  • DC to 200 MHz bandwidth 
  • 100:1 attenuation Isolated
  • BNC connector type 
  • For ScopeCorder Isolated Modules

Passive Probe, 1000V(DC+ACpeak) CAT II, 60MHz, 10:1, 10MΩ, 2.5m
Wide operating temperature range(-40 to 85°C)
For isolated BNC input modules for ScopeCoder series

  • 701974 Low Capacitance Probe
  • 5 GHz, 20:1 / 10:1, 20 Vrms / 40 VACpeak, 1.1 m, For DLM series
  • Low input capacitance
  • Low input resistance
  • 700939 Active FET Probe
  • 900 MHz Active FET Probe Circuit
  • 10:1, ±10 V (DC + ACpeak) FET Input Active Probe
  • 1.5 m

 

Overview:

After a disastrous 2009, the large publicly held test companies enjoyed booming business in 2010.

Brochures

Looking for more information on our people, technology and solutions?


Contact Us

Precision Making