CLAMP-ON TESTERS

With our 16 models of different clamp-on testers, Yokogawa provides the right tool for the job. Our CL Series consists of AC, AC/DC, and leakage current clamps with various ranges and dimensions. The multiple options include RMS, Mean, Temperature, frequency, and recorder output.

Mini Clamp-on Tester for AC Current #CL120

Mini Clamp-on Tester for AC Current #CL120

  • Exclusive model for AC current measurement with current ranges up to 200A
  • 24mm in diameter of measurable conductor
  • Light weight & compact design
  • Mean value display
  • Data hold function
  • Approved for comformity to safety standards EN61010-1,
  • EN61010-2-032 (CAT. Ill 300 V)

ACA, ACV Clamp-on Tester for AC Current #CL130

ACA, ACV Clamp-on Tester for AC Current #CL130

ACA, ACV - Clamp-on Tester for AC Current

  • AC current measurement with current ranges up to 600A
  • AC voltage and resistance measurements
  • 30mm in diameter of measurable conductor
  • Mean value display
  • Data hold function
  • Approved for comformity to safety standards EN61010-1,
  • EN61010-2-031, EN61010-2-032 (CAT. Ill 600 V)

True RMS ACA, ACV Clamp-on Tester for AC Current #CL135

True RMS ACA, ACV Clamp-on Tester for AC Current #CL135

True RMS ACA, ACV - Clamp-on Tester for AC Current

  • AC current measurement with current ranges up to 600A
  • AC voltage and resistance measurements
  • 30mm in diameter of measurable conductor
  • True RMS Display
  • Data hold function
  • Approved for comformity to safety standard EN61010-1,
  • EN61010-2-031, EN61010-2-032 (CAT. Ill 600 V)

ACA, ACV, DCV, OHM, Continuity Check Clamp-on Tester for AC Current #CL150

ACA, ACV, DCV, OHM, Continuity Check Clamp-on Tester for AC Current #CL150

ACA, ACV, DCV, OHM, Continuity Check - Clamp-on Tester for AC Current

  • AC current measurement with current ranges up to 2000A
  • AC/DC voltage and resistance measurements
  • 54mm in diameter of measurable conductor
  • Mean value display
  • DC output function
  • Data hold function
  • Sleep function
  • Approved for comformity to safety standards EN61010-1,
  • EN61010-2-031, EN61010-2-032 (CAT. m 600 V, CAT. II1000 V)

AC True RMS Clamp-on Tester for AC Current #CL155

AC True RMS Clamp-on Tester for AC Current #CL155

AC True RMS - Clamp-on Tester for AC Current

  • AC current measurement with current ranges up to 2000A
  • AC/DC voltage and resistance measurements
  • True RMS display
  • 54mm in diameter of measurable conductor
  • DC output function
  • Data hold function
  • Sleep function
  • Approved for comformity to safety standards EN61010-1, EN61010-2-031, EN61010-2-032 (CAT. HI 600 V, CAT. II1000 V)

Clamp-On Tester for AC/DC Current #CL220

Clamp-On Tester for AC/DC Current #CL220

Clamp-on Testers For AC/DC Current

  • AC/DC current measurements with current ranges up to 300A
  • 24mm in diameter of measurable conductor
  • Light weight & compact design
  • Mean value display
  • Sleep function
  • Approved for comformity to safety standards EN61010-1, EN61010-2-032 (CAT. III 300 V)

Clamp-on Tester For AC/DC Current #CL235

Clamp-on Tester For AC/DC Current #CL235

Clamp-on Testers For AC/DC Current

  • True RMS display
  • AC/DC current measurements with current ranges up to 600A for
  • AC and 1000A for DC
  • AC/DC voltage, resistance and frequency measurements 33mm in diameter of measurable conductor
  • Sleep function
  • Data hold function
  • Approved for comformity to safety standards EN61010-1,EN61010-2-031, EN61010-2-032 (CAT. III 600 V)

Clamp-on Tester for AC/DC Current #CL250

Clamp-on Tester for AC/DC Current #CL250

Clamp-on Testers For AC/DC Current

  • AC/DC current measurements with current ranges up to 2000A
  • AC/DC voltage and resistance measurements
  • DC output
  • 55mm in diameter of measurable conductor
  • Mean value display
  • Sleep function
  • Data hold function
  • Approved for comformity to safety standards EN61010-1, EN61010-2-031, EN61010-2-032 (CAT. III 600 V, CAT. II 1000 V)

Clamp-on Tester for AC/DC Current #CL255

Clamp-on Tester for AC/DC Current #CL255

Clamp-on Testers For AC/DC Current

  • True RMS display
  • AC/DC current measurements with current ranges up to 2000A
  • AC/DC voltage and resistance measurements
  • DC output
  • 55mm in diameter of measurable conductor
  • Sleep function
  • Data hold function
  • Approved for comformity to safety standards EN61010-1,EN61010-2-031, EN61010-2-032 (CAT. III 600 V, CAT. II 1000 V)

Clamp-on Tester for Leakage Current #CL320

Clamp-on Tester for Leakage Current #CL320

Clamp-on Testers For Leakage Current

  • Leakage current measurement with current range from 20mA to 200A
  • Light weight and compact design
  • Manual range switching and auto power-off functions
  • 24mm in diameter of measurable conductor
  • Mean value display
  • Auto power-off
  • Manual range switching
  • Approved for comformity to safety standards EN61010-1, EN61010-2-032(CAT. III 300 V)

Clamp-on Tester for Leakage Current #CL340

Clamp-on Tester for Leakage Current #CL340

Clamp-on Testers For Leakage Current

  • Leakage current measurement with current range from 40mA to 400A
  • Light weight and compact design
  • Manual range switching and auto power-off functions
  • 40mm in diameter of measurable conductor
  • Mean value display
  • Auto power-off
  • Manual range switching
  • Approved for comformity to safety standards EN61010-1, EN61010-2-032(CAT. III 300 V)

Clamp-on Tester for Leakage Current #CL345

Clamp-on Tester for Leakage Current #CL345

Clamp-on Testers For Leakage Current

  • Leakage current measurement with current range from 40mA to 400A
  • Manual range switching and auto power-off functions
  • 40mm in diameter of measurable conductor
  • True RMS display
  • Auto power-off
  • Manual range switching
  • Approved for comformity to safety standards EN61010-2-032 (CAT. III 300 V)

Clamp-on Tester for Leakage Current #CL360

Clamp-on Tester for Leakage Current #CL360

Clamp-on Testers For Leakage Current

  • Leakage current measurement with current range from 200mA to 1000A
  • AC and DC output
  • 68mm in diameter of measurable conductor
  • Approved for conformity to safety standards EN 61010-1, EN 61010-2-032 (CAT III 300 V)

Clamp-on Process Meter for DC mA Current #CL420

Clamp-on Process Meter for DC mA Current #CL420

This device allows the user to make safe current checks of 4 to 20mA without breaking the loop. In addition, the output function provides a simple way to log and monitor the data.

  • 0.2% Accuracy, 0.01mA Resolution
  • Dual Display
  • LED Torch Light, Backlight Display
  • Analog Output Available

Clamp-on Tester for Leakage Current #30031A/30032A

Clamp-on Tester for Leakage Current #30031A/30032A

Clamp-on Testers For Leakage Current

  • Leakage current measurement range from 3mA to 60A
  • Diameter of measurable conductor: 40 mm max.
  • Easier and clear display


All Products Guide