Probes

What is a Probe?

A probe is a device that takes and relays measurements.

Types of Probes

  • Differential probes- active analog voltage probe types including switch probes, available for high-speed and high-voltage needs.
  • Logic probes- monitor signals temperature probes, either isolated or non-isolated (compare to multimeter probes).
  • Active probes- analog voltage probe types, including differential and single-ended.
  • Passive probes- analog voltage probe types, available in general-purpose, high voltage, and low capacitance needs.
  • Miniature Passive probes
  • Clamp-on probes
  • 400 MHz bandwidth
  • ±1 kV max. differential voltage
  • 70 dB CMRR (1 MHz)
  • Interface: BNC
  • 400 MHz bandwidth
  • ±2 kV max. differential voltage
  • 70 dB CMRR (1 MHz)
  • Interface: BNC
  • 50 MHz bandwidth
  • ±7 kV max. differential voltage
  • 50 dB CMRR (1 MHz)
  • Interface: BNC
  • 150 MHz bandwidth
  • ±1.5 kV max. differential voltage
  • 50 dB CMRR (1 MHz)
  • Interface: BNC
  • Ideal for vehicle bus monitoring
  • 200 MHz bandwidth
  • 20 V max. differential voltage
  • Interface: Yokogawa DLM Series

  • 150 MHz bandwidth
  • ±1.4 kV max. differential voltage
  • 50 dB CMRR (1 MHz)
  • Interface: Yokogawa DLM Series

  • 1000 V (DC+ACpeak), 200 MHz
  • Impedance (10 MΩ | 16 pF)
  • CAT II rating, 2.5 m
  • -40 to +85 °C operating temperature
  • 600 V (DC+ACpeak), 500 MHz bandwidth
  • Impedance (10 MΩ | 10.5 pF)
  • CAT II rating, 1.3 m
  • Ideal for DLM3000/3000HD, DLM5000/5000HD
  • 600 V (DC+ACpeak), 200 MHz bandwidth
  • Impedance (10 MΩ | 13.5 pF)
  • CAT II rating, 1.5 m
  • Ideal for DLM2000
  • 600 V (DC+ACpeak), 500 MHz bandwidth
  • Impedance (10 MΩ | 10.5 pF)
  • CAT II rating, 1.3 m
  • Ideal for DL6000, DLM2000 (350/500 MHz models), DLM4000/6000

  • 600 V (DC+ACpeak), 10 MHz bandwidth
  • Impedance (10 MΩ | 22 pF)
  • 1.3 m total length
  • Ideal for non-isolated ScopeCorder modules

  • 400 Vrms, 500 MHz bandwidth
  • Impedance (10 MΩ | 9.5 pF)
  • Ideal for DL6000, DLM2000/4000/6000
  • 1000 Vrms, 400 MHz 
  • Impedance (50 MΩ | 7.5 pF)
  • CAT II rating, 1.2 m
  • 0 to +50 °C operating temperature
  • 1000 Vrms, 250 MHz 
  • Impedance (50 MΩ | 7.5 pF)
  • CAT II rating, 3 m
  • 0 to +50 °C operating temperature
  • 1000 V (DC+ACpeak), 100 MHz bandwidth
  • Impedance (10 MΩ | 18 pF)
  • CAT II rating, 1.7 m
  • 1000 V (DC+ACpeak), 60 MHz bandwidth
  • Impedance (10 MΩ | 17 pF)
  • CAT II rating, 2.5 m
  • -40 to +85 °C operating temperature
  • 3540 V (DC+ACpeak), 200 MHz bandwidth
  • Impedance (100 MΩ | 7 pF)
  • 1.7 m total length
  • 20 Vrms
  • 5 GHz bandwidth
  • 450 Ω | 0.25 pF and 950 Ω | 0.4 pF
  • 10 V (DC+ACpeak), 900 MHz bandwidth
  • Impedance (2.5 MΩ | 1.8 pF)
  • Compatible with any Yokogawa oscilloscope

 

  • 600 V (DC+ACpeak), 500 MHz bandwidth
  • Impedance (10 MΩ | 12.5 pF)
  • CAT II rating, 1.5 m
  • Ideal for DL9000/9500/9700, SB5000

1 set 4 pcs Red Black White Blue Ø 4 mm Approx. 3 m

  • 701917 oscilloscope current probe
  • Frequency bandwidth: DC to 50 MHz
  • Maximum continuous input range: 5 Arms
  • Functions with Digital Oscilloscopes, ScopeCorders, other waveform measuring instruments
  • Yokogawa 701918 Current Probe
  • Frequency bandwidth: DC to 120 MHz
  • Maximum continuous input range: 5 Arms
  • Functions with Digital Oscilloscopes, ScopeCorders, other waveform measuring instruments
  • 701928 scope current probe
  • Front-end powered
  • Recognized automatically
  • Adjust zero position from operation of DLM2000, DLM3000, DLM4000, DL6000/DLM6000, DL9000/DLM9000. SB5000 
  • 701929 Current Probe 50 MHz / 30 ARMS
  • Front-end powered
  • Auto-recognized
  • DLM2000-4000, DL/DLM6000, DL/DLM9000, SB5000
  • 701930 Current Probe 10 MHz / 150 ARMS
  • Powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply
  • 701931 Current Probe 2 MHz / 500 ARMS
  • Powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply
  • 701932 Current Probe 100 MHz / 30 ARMS
  • Powered by Yokogawa Digital Oscilloscopes, Scopecorders, or external power supply
  • 701933 Current Probe 50 MHz / 30 ARMS
  • Powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply

The 720930 and 720931 passive clamp-on current probes allow current waveform readings directly via analog input modules on ScopeCorders using isolated BNC connections.

  • AC 50 A
  • 40 Hz to 3.5 kHz Bandwidth

The 720931 passive clamp-on current probe anables current waveform readings directly via analog input modules on ScopeCorders including the DL350 and DL850 using isolated BNC connections.

  • AC 200 A
  • 40 Hz to 3.5 kHz Bandwidth

Special AC-Input Clamp-on Probes for Large-current Hot Line Measurement

  • 96030 Clamp-on Current Probe
  • AC 200 A: output AC 2.5 mV/A
  • 96031 Current Clamp for Multimeter
  • AC 500 A: output AC 1.0 mV/A
  • 96033 Clamp-on Current Probe
  • AC 50 A: output AC 10 mV/A

φ40 mm AC 2 A, Leakage current measurement.

  • 96061 Clamp-on probe
  • φ18 mm AC 50 A, Load current measurement
  • 96062 Clamp-on Probe
  • Load current measurement
  • φ24 mm AC 100 A

φ30 mm AC 200 A, Load current measurement.

φ40 mm AC 500 A, Load current measurement.

  • 96065 Current clamp-on probe
  • max. approx. 110 mm
  • AC 1000 A flexible type load current measurement
  • 96066 Clamp-on probe
  • max. approx. 150 mm
  • AC 3000 A, 3 CH Load current measurement

AC/DC clamp probe
AC: 130 A (40 Hz to 1 kHz)
DC: ±180 A

  • 8-bit, 1 MΩ input resistance (PBL100)
  • Toggle frequency of 100 MHz
  •  
  • 8-bit,100 kΩ input resistance (PBL250)
  • Toggle frequency of 250 MHz
  •  
  • 8-bit, non-isolated; response: ≤3 µs; threshold approx. 1.4 V
  • TTL level/contact input cables: 702911: 1 meter, 702912: 3 meter
  •  
  •  
  • 8-bit, non-isolated, response speed: 1µs, threshold level approx 1.4V
  • Leads (B9879PX and B9879KX) included.
  • 8-bit, isolated; response: ≤1 ms (DC), ≤20 ms (AC); threshold: 6 VDC or 50 VAC.
  • 758917 and 758922, 758929, 701954 

90029B -40 to 260°C (Bead TC)

90020B -50 to 600°C (rounded end)
90021B -50 to 600°C (rounded end)
90022B -50 to 600°C (rounded end)
90023B -50 to 500°C (needle)
90024B -50 to 500°C (needle)
90029B -40 to 260°C (Bead TC)

90030B  -20 to 250°C  (Surface straight)
90031B  -20 to 250°C  (Surface angled)
90032B  -20 to 500°C  (Surface straight)
90033B  -20 to 500°C  (Surface angled)

90050B -50 to 600 ° C (For liquids)
90051B -50 to 600 ° C (For liquids)
90055B -20 to 250 ° C (For surfaces)
90056B -20 to 500 ° C (For surfaces)

Length: 1.4 m, MY600 only

Length: 2.0 m, Earth probe and alligator clip adapters

Size: 61.9 × 26 mm

Logic probe accessory kit for use with 701989.

  • 701919 oscilloscope probe stand
  • Flexible arm, heavy base to hold and stabilize 8-13mm probes
  • Can simplify circuit board testing
  • 701934 External Probe Power Supply
  • Power supply for current probes, FET probes, and differential probes
  • Supplies power for up to four probes, including large current probes

  • 1000 V (DC+ACpeak), 200 MHz
  • Impedance (10 MΩ | 18 pF)
  • CAT II rating, 2.5 m
  • -40 to +85 °C operating temperature
  • 400 Vrms, 500 MHz bandwidth
  • Impedance (10 MΩ | 9.5 pF)
  • Ideal for DLM3000/3000HD/5000/5000HD
  • 702915 Current Probe 50 MHz / 0.5 ARMS, 5 ARMS, 30 ARMS
  • Powered by Digital Oscilloscopes, ScopeCorders, other waveform measuring instruments

Frequency bandwidth: DC to 120 MHz
Maximum continuous input range: 0.5 Arms/5 Arms/30 Arms
Functions with Digital Oscilloscopes, ScopeCorders and other waveform measuring instruments

Industry leading high precision, high current AC/DC split core measurement. Compatible with power analyzers and waveform measurement instruments.

  • 400 MHz bandwidth
  • ±1 kV max. differential voltage
  • 70 dB CMRR (1 MHz)
  • Interface: Yokogawa DLM Series
  • 400 MHz bandwidth
  • ±2 kV max. differential voltage
  • 70 dB CMRR (1 MHz)
  • Interface: Yokogawa DLM Series

 