Bandwidth |
: |
DC to 150 MHz |
Attenuation |
: |
500:1/50:1 |
Max. Input Voltage |
: |
±1400 V (DC + ACpeak) or 1000 Vrms CAT II |
Max. Differential Voltage |
: |
±1400 V (DC + ACpeak) at 500:1 attenuation |
Probe Power |
: |
dedicated probe interface |
1m Extension Lead Set is bundled |
1400 Vpeak capability is suitable for un-grounded and floating voltage measurements in power electronics and mechatronics applications including inverters, motor drives, and power supplies. 1 m long extension lead pair is included as a standard accessory. Standard pincher tips are exchangeable a wide variety of 4mm safety adapters (sold separately). The 701927 isolated differential probe has a reduced size and weight over comparable probes (50% reduced volume over the Yokogawa 700924).
Input type | Balanced differential input |
---|---|
Frequency band | DC TO 150 MHz (-3 dB) |
Input attenuation ratio | 50:1 and 500:1, user selectable |
Input impedance | Approximately 4 MΩ |
Maximum allowed differential voltage | ± 1400 V(DC+ACpeak) (1/500) |
Maximum common mode input voltage | ± 1400 V(DC+ACpeak) or 1000 Vrms |
Common Mode Rejection Ratio (CMRR) | -80 dB (60 Hz), -50 dB (1 MHz) |
Output voltage | ±2.8 V |
Output impedance | Used with 1 MΩ input impedance |
Power Supply | Yokogawa Probe Interface Only |
External dimensions (approximate) | 174 mm x 58 mm x 27 mm |
Total length | Approximately 2.4 meters |
Weight | Approximately 500 grams |
Approved standards |
To best utilize SiC devices for improved energy efficiency in equipment, it is important to optimize the internal device peripheral circuits in the inverter according to the device characteristics.