WTVIEWER (760122) UPDATE

WTViewer acquires numeric, waveform, and harmonic data from the WT3000/WT1600/WT500 Digital Power Analyzer via Ethernet, GP-IB or serial communications (RS-232) and USB. Data can be transferred into your personal computer via Ethernet, GP-IB (parallel) or RS-232 (serial) communications and USB. It lets you view waveforms on your computer, convert numeric or waveform data to a specified format, and store the data.
page links
Details
section links
Functions
View, convert, and store data to your specifications with WT Series.- Computation with data from multiple units (WT3000/WT1600/WT500)
- Ethernet Functions
- Displaying Data on the PC
- Setting Up the WT3000/WT1600/WT500 from a PC
- Convering Data to CSV Format
- Communication functions supported by WTViewer
- Includes file reader software functionality
Ethernet Functions
*Requires the WT3000/WT1600/WT500's optional Ethernet function to utilize this functionFTP Server/FTP Client
![]() |
WTViewer can simultaneously control up to four WT500s, four WT1600s or four WT3000s for multi-channel measurement. |
![]() |
The FTP client function makes it possible to transfer data saved in the WT3000/WT1600/WT500 internal memory to your PC. |
PC Connections

PC Direct Connection
[GP-IB/serial (RS-232)/Ethernet, and USB]
* Ethernet connection requires two straight cables and a HUB.
|
|
|
Example of Ethernet Network Connection

Screen Details
Numeric Data![]() |
You can display the data measured with the WT3000/WT1600/WT500 on your PC via Ethernet/GP-IB/RS-232 communication and USB. WTViewer can also simultaneously show various parameters for one to six elements and for SA to SC calculations, for simple channel-by-channel data comparison. |
Measuring Harmonics
![]() |
With WTViewer, you can control the WT3000/WT1600/WT500 main unit from your PC, including setting the wiring method, range, filter, and scaling, and so on. |
Viewing Trends
|
You can capture various types of data measured with the WT3000/WT1600/WT500 in your PC at fixed intervals. Thus, you can view trends graphically. This feature lets you monitor power supply voltage fluctuations, changes in current consumption and other time-based variations. |
Vectorial Views
![]() |
In harmonic measurement, you can have a vectorial view of the fundamental voltage, current and phase angle. This visual presentation of the interphase relationship in a three-phase power system shows the load condition intuitively. |
Setting Up the WT Power Analyzer from a PC
![]() |
With WTViewer, you can control the WT3000/WT1600/WT500 main unit from your PC, including setting the wiring method, range, filter, and scaling, and so on. WTViewer also lets you save or read the settings of the Power Analyzer onto your PC. |
Converting Data to CSV Format
![]() |
With WTViewer, you can save waveform and numeric data to your PC, while on the PC you can create *.wtd files that can be loaded in WTViewer, or *.csv files that can be imported into Excel spreadsheets. WTViewer also lets you save screen images of measured numeric and waveform data.
Note: The screenshot is a display example from the WT1600. |
WT3000/WT1600: Computation with Data from Multiple Units
| Enables acquisition of data from multiple units WTViewer can acquire data from up to four units simultaneously. Plus, it now includes accurate computation functions that can perform addition, subtraction, and efficiency computation of data from multiple powermeters. For example, three-phase power from the first unit (A) and three-phase power from the second unit (B) can be measured on WTViewer and subsequently used in up to 15 different user-defined expressions such as A+B, or B/A*100 (efficiency). ![]() Note: Requires that the WTs be of the same model and option code. Not supported if the WT3000 and WT1600 are combined. ![]() |
Viewer Software for Data Acquired Offline
| Until now, measured data acquired offline and saved to the WT's memory media could be loaded and displayed on a PC, but required running a file reader program that was separate from WTViewer. With the new version upgrade, the file reader program has now been conveniently integrated with WTViewer. * Even after the 30-day trial period of the demo version, users can continue to use the "Off-Line + File Loading with WTFileReader" function. ![]() |
Specifications
Applicable Power Meter:WT1600 firmware version 1.05 or later for GP-IB/serial (RS-232)
WT1600 firmware version 2.01 or later for GP-IB/serial (RS-232)/Ethernet
WT3000 firmware version 2.01 or later for GP-IB/serial (RS-232)/Ethernet/USB
| Functions | |
| Measuring Mode | Power measurement, integration, and harmonic measurement |
| Types of Files |
Waveform files (1002 points, peak to peak compression data), computation files, harmonic files, and setup files |
| Screen Viewer |
Numeric view, waveform view, trend view, vectorial view, and bar-graph view |
Data Acquisition Interval |
50 ms at max. speed (WT1600) In Fast mode, using GP-IB. Depends on your PC's performance. * When the data update rate is set to one second or slower, captured and saved data can be synchronized. |
| System Requirements | ||
| Personal Computer | CPU | Celeron 500 MHz or higher recommended |
| Memory |
128 MB or greater is recommended |
|
| VRAM |
4 MB minimum |
|
| Hard Disk |
Free space of at least 100 MB |
|
| OS |
Windows 98, Windows Me, Windows NT, or Windows 2000 (English Version) |
|
| Display Resolution |
800x600 pixels or higher |
|
Communications Port |
Ethernet: Transmission method 10Base-T |
|
| RS-232: COM port of the PC should be available |
||
| GP-IB: AT-GPIB/TNT (PnP) or later, with driver NI-488.2M version 1.60 or later, from National Instruments |
||
| USB |
||
软件
| 姓名 | 描述 | |
|---|---|---|
| WTViewer 760122 (trial version) | WTViewer acquires numeric, waveform, and harmonic data from the WT3000/WT1600 Digital Power Meter via Ethernet, GP-IB or serial communications (RS-232). |
y-Link |
| WTViewer 760122 (upgrade version) | WTViewer acquires numeric, waveform, and harmonic data from the WT3000/WT1600 Digital Power Meter via Ethernet, GP-IB or serial communications (RS-232). | y-Link |