集成软件平台 IS8000
横河仪器的统一性可确保产品研发过程中的测量一致性,允许在整个组织内轻松共享数据。IS8000通过在统一的显示屏幕中查看所有测量值,让调试和分析数据更加简单。
IS8000能够在开发测试系统上花费更少的时间,而将更多的时间用于收集有价值的测试数据,从而有效地简化产品开发流程。使用一套软件来设置和控制所有需要的仪器,这样可以更快、更有效地开始测量数据。
使用一种格式在同一位置存储数据从未如此简单。 IS8000通过利用IEEE1588时基获得多台仪器之间同步测量的结果,提供可靠的数据。
伴随当今技术的快速发展,具有扩展能力的软件至关重要。 IS8000可以随着需求的发展而演变,使用附加软件包即可实现对数据的深入分析。
Version | Date | Description |
---|---|---|
V24.3.1.0 | Sep 26, 2024 | Released IS8002CDV Classic Data Viewer. Increased the number of groups and the maximum number of channels per group for offline analysis. Fixed bugs and improved performance. |
Previous version
Ver. 24.3.1.0
Previous version
The IS8000 software platform is an integrated solution that accelerates engineering workflow. It is a revolutionary software solution that tightly integrates the timing, control, and data collection from multiple instruments, creating a comprehensive measurement suite that delivers high confidence, efficiency, and unity.
In combination with the 10 GbE option (C60 option) on the DL950 and the IS8000, up to 8 channels of data can be stored in real time on a PC at a sampling rate of up to 20 M samples per seconds.*
Longer recording times are now possible for high-speed, multi-channel inputs such as gate signals and switching waveforms of multi-phase inverters.
* With 1 Gb Ethernet/USB connection, the maximum transfer rate is 6.4 MB/s (200 kS/s × 16 ch)IS8000 and SY1 option enable accurate power and waveform data synchronization across multiple channels with minimal error. Data from the WT5000 power analyzer and DL950 ScopeCorder is time correlated with less than 10 us error using IEEE1588 technology.
YOKOGAWA’s high-precision power analyzer, ScopeCorder and oscilloscope can be remotely operated, monitored and configured from IS8000. Additional options, third-party high-speed cameras can also be controlled, greatly reducing the burden of operating and managing various instruments measuring power, physical phenomenon, video, and control signals.
Measure up to 16 FFT processes for a wealth of analysis functions for automatic calculation of frequency and integrated value and filter processing.
Customized reports are easily created by dragging and dropping measurement data, waveforms, graphs, etc. onto the sheet.
The IS8000 supports binary, ASCII, and the MDF format, a very common format for the automotive industry. Power and waveform data on the IS8000 can be shared with your development system or third-party software.
*1 Import of MDF files generated by other software/devices will be supported in the futureIS8000 synchronizes high speed camera images with related current, voltage, and control signals. Simultaneous slow motion playback allows visualization between design and results.
In addition, video files captured by other than high-speed camera and waveform files can be synchronized offline for display and analysis.
IEEE 1588 is a standard for the Precision Time Protocol (PTP), a protocol for high-precision time synchronization of networked instruments and control systems. The PTP grandmaster server provides a reference clock for each client instrument to achieve high-precision clock synchronization. Since the ScopeCorder DL950 has the PTP master function, high precision clock synchronization of the corresponding instruments on the same network is possible even without a PTP grandmaster server. The IS8000 is also capable of combining the simultaneous measurement data of each of these PTP-synchronized instruments in the same window.
This is an analysis function for CAN bus communication widely used in in-vehicle networks and other applications. It enables decoding of communication contents, frame display, and search for specific information in CAN bus communication signal. This new serial bus analysis option can also be used to analyze signal waveforms acquired not only by Yokogawa's oscilloscopes but also by the ScopeCorder series and IS8000. It is effective for reanalysis of communication signal waveforms previously measured, and for comparison and analysis with other physical quantity measurements.
Modbus/TCP communication. A communication configuration file for connection to the YOKOGAWA GM10 and VZ20X recorders is included with the software. Other Modbus/TCP communication devices can also be connected to the IS8000 by creating a communication configuration file using the included tool. Integration of these devices with a Yokogawa Test & Measurement’s power analyzer and waveform measuring instrument by the IS8000 will provide a measurement system that supports more input channels, longer recording times and a wider variety of temperature sensors.
Screenshot example of data acquisition with Yokogawa's GM10 and DL950
Modbus configuration file editor
IS8011/IS8012 optional software package is designed to perform harmonic and flicker tests in accordance with IEC61000-3-2, 3-3, 3-11 and 3-12 standards using the WT5000 precision power analyzer. Users can easily set the conditions and output the test report without any specialized knowledge. Users can make a pass/fail judgment by class A, B, C, and D of the harmonic current measurement values.
Compatible measurement device:
WT5000 (/G7 option required)
Applicable standards:
IEC 61000-3-2 Harmonic Measurement
IEC 61000-3-3 Voltage Fluctuation and Flicker Measurement
Voltage fluctuation and flicker suppression standards
Flicker meter function and design specifications
IEC 61000-3-11 Voltage Fluctuation and Flicker Measurement
Voltage fluctuation and flicker suppression standards
Flicker meter function and design specifications
IEC 61000-3-12 Harmonic Measurement
Functions | Supported devices |
---|---|
Online data acquisition | DL950, WT5000 |
Remote control and setting, acquisition data download | DL350, DL850 series, DL950, DLM3000 series, DLM3000HD series (will be supported by the future update.), DLM5000 series, DLM5000HD series, WT5000 (Remote control and setting only) |
Data File Import | DL350, DL850 series, DL950, DL750 (Only WVF file), SL1400 (Only WVF file) , SL1000, WT1800 series, WT3000 series, WT5000, DLM2000 series, DLM3000 series, DLM3000 series, DLM3000HD series (will be supported by the future update.), DLM4000 series, DLM5000 series, DLM5000HD series |
High-speed camera Sync. (FS1 option) |
Supported cameras for online sync.: Photron’s FASTCAM SA-Z, MIni UX*/AX/WX series, NOVA S series, NOVA R2 Supported devices for online sync.: DL950 |
Modbus/TCP Communication (MB1 option) |
Devices supported Modbus/TCP protocol. |
ECU Monitor sync. (EM1 option) |
DTS INSIGHT's RAMScope GT170(only for the variable data acquisition and calibration module), GT122 |
* Pre-trigger recording and multi-trigger recording using the Mini UX series in combination with the FS1 option are not supported.
The writings in red are changes from the previous version.
Ver. 24.3.1.0 | ||
Connecting support firmware | DL950 | Ver.1.50 or later |
WT5000 | Ver. 3.31 or later | |
Languages | English / Chinese / Japanese | |
PC requirements | For data acquisition with 10 Gb Ethernet connection; CPU: Desktop PC required Intel Core i7-1165G7 or later Intel CPU 4 cores(8 threads) or more 4.7 GHz or faster Amount of memory: 16 GB or more Amount of SSD: 512 GB or more(M.2 slot is recommended, Sequential read/write 3 GB/s or faster) For data acquisition with 1 Gb Ethernet/USB connection and offline analysis; CPU: Intel Core i5-10210U or later Intel CPU 4 cores(8 threads) or more 4.2 GHz or faster Amount of memory: 8 GB or more Amount of SSD: 256 GB or more(Sequential read/write 400 MB/s or faster) |
|
OS | Windows 11 Pro or Enterprise edition (except EM1 option) Windows 10 64bit Pro or Enterprise edition |
|
Communication interface | USB (USBTMC / VISA), Ethernet (VXI-11, HiSLIP, Modbus/TCP *8) | |
Display resolution | 1366×768 dots or higher, 100 % zoom | |
Number of connectable units | Up to 5 units (Only one unit without SY1 option) (SY1 option is required even if the time synchronisation is not used) |
|
Supported file format | WDF | DL350, DL850 series, DL950, SL1000, DLM2000 series, DLM3000 series, DLM3000HD series*11 , DLM4000 series, DLM5000 series,DLM5000HD series |
CSV (Waveform data) | DL950, DL850 series, DL350, DLM5000HD/5000/4000/3000HD*11/3000/2000 series, Xviewer Application Software and IS8000 *6 | |
CSZ | IS8000 CSV data compressed in ZIP format | |
CSV (Power measurement data)*2 | WT5000, WT3000 series*1, WT1800 series | |
WVF | DL750, SL1400 | |
MF4 | IS8000 data files ASAM MDF 4.1 files |
|
mepjt, anpjt | IS8000 Project files | |
Export file formats | ASAM MDF 4.1 files (mf4), ASCII files (csv), CSV files compressed in ZIP format (csz) | |
Online data acquisition (DL950)*7 |
Motion mode | Scope mode (Trigger/ Free-run)*4 The trigger mode cannot be used with multi-unit synchronized DL950s. |
Maximum transfer rate | 10Gb Ethernet connection: 320MB/s (20MS/s x 8ch, 10MS/s x 16ch) 1Gb Ethernet / USB connection: 6.4MB/s (200kS/s x 16ch) |
|
Online data acquisition (WT5000)*7 |
Monitoring/DAQ items | Power trend graph and numeric Harmonic bar graph *9*10 Data-streaming waveform *3 Vector diagram |
Online data acquisition (common)*7 |
Maximum continuous recording time/size | The recording will be kept until free storage space falls below 10%. |
Maximum recording channels | 128 channels | |
Display format | Common | TY-Overview (up to 128 ch for each group, up to 16 group), XY (up to 2 windows for each group), TY-View (up to 4 areas for each group), Numeric Monitor(Up to 128 channels) |
For WT5000 | Power trend graph and numeric display Peak-to-peak compressed waveform (Data update interval: 1s or slower) Bar graph of the amplitude and phase of each harmonic *9*10 Data streaming waveform display *3 Harmonic list display Matrix display Vector diagram |
|
Waveform overlays | Aligned by time, absolute time ,head of data, end of data or arbitrary position | |
Automated waveform parameter measurements | Parameters | Up to 28 parameters (including P-P, Amp, RMS and Freq). |
Automated measurement of history statistics | Waveform parameters for each waveform in the historical memory and their statistics can be calculated automatically. | |
Automated measurement of cycle statistics | Waveform parameters of each period of a cyclic waveform and their statistics can be calculated automatically. | |
Cursor | Vertical (up to 2 curors in a window), Horizontal (up to 2 curors in a window) | |
Annotation | Comments, acquired data and calculated values can be added on the overview/view, waveform window and X-Y window. | |
Supported devices | Data acquisition | DL950 WT5000(760903 Current Sensor Element supported.10ms update rate supported.) |
Flash ACQ data saving | DL950 | |
Data file import | DL350, DL850 series, DL950, SL1000, WT1800 series, WT3000 series, WT5000, DLM2000 series, DLM3000 series, DLM3000HD series*11, DLM4000 series, DLM5000 series,DLM5000HD series, DL750 (Only WVF files), SL1400 (Only WVF files) | |
Remote control and setting, acq. data download | DL350, DL850 series, DL950, DLM3000 series, DLM3000HD series*11, DLM5000 series,DLM5000HD series, DLM4000/2000 series, WT5000(Remote control and setting only) | |
Screen Capture | Save | Clipboard, png, jpg, gif |
CSV batch converter | Load | MF4 (MDF4.1), WDF, WVF |
Save | CSV, CSZ (CSV compressed in ZIP format) | |
Mathematical data analysis(MH1) | Number of Math channels | Up to 16 channels |
Operators | +, -, x, /, Phase shift, ABS, SQRT, LOG, EXP, RMS, NEG, SIN, COS, TAN, ATAN, PH, DIF, DDF, INTEG, BIN, P2, P3, F1, F2, FV, PWHH, PWHL, PWLH, PWLL, PWXX, DUTYH, DUTYL, FLT1, FLT2, HLBT, MEAN | |
Number of computed points | Up to 12.5 M points or up to100 M points can be supported by installing MATLAB Runtime |
|
Digital filters | Gauss, Sharp, IIR(Butterworth) | |
FFT analysis (MH1) | Operator | Type: LS, RS, PS, PSD, CS, TF, CH Sub-type: REAL, IMAG, MAG, LOGMAG, PHASE |
Window function | Rect, Hanning, Flat top, Hamming | |
Number of FFT channels | Up to 16 channels independently | |
Number of computed points | Up to 2 M points or up to100 M points can be supported by installing MATLAB Runtime |
|
Serial bus analysis(SB1) | supported protocol | CAN (CAN FD is not supported at present.) |
Search target | SOF, ID/Data, Error | |
Number of search points | Up to 100,000 frames | |
Bit rate | Select the value from 33.3kbps, 83.3kbps, 125kbps, 250kbps, 500kbps,1Mbps, or enter it within the range of 10kbps to 1Mbps in 0.1kbps steps. | |
Report Generator (RP1) | Export | Microsoft Word, Excel, PDF, Print |
Components | Waveforms, Measurement data, Comments, Images | |
High-speed camera Sync. (FS1) | Supported cameras for online sync | Photron’s FASTCAM SA-Z, MIni UX*5/AX/WX series, NOVA S series, NOVA R2 |
Supported video format for online sync | high-speed camera video files(avi) | |
Supported devices for online sync | DL950 | |
Supported video file formats for offline sync | AVI(*.avi), MP4(*.mp4), WMV(*.wmv), AVCHD(*.mts), MOV(*.mov), MPEG2-PS(*.mpg, *.mpeg) | |
ECU Monitor sync.(EM1) | Supported monitoring tools | DTS INSIGHT's RAMScope GT170(only for the variable data acquisition and calibration module), GT122 |
Supported data file | RAMScopeVP output files(a2l) | |
Supported devices for online sync | DL950 |
*1 Harmonic measurement data excluded.
*2 The measurement data of first 128 channels can be imported.
*3 /DS option is required for the WT5000 to be connected.
*4 Trigger DAQ with DL950 external clock input is not supported.
Freerun DAQ with DL950 external clock input, including 16-channel input module or CAN/CAN FD/LIN/SENT module, is not supported.
*5 Pre-trigger recording and multi-trigger recording using the Mini UX series in combination with the FS1 option are not supported.
*6 Only CSV files saved with Ver. 22.6.1.0 or later IS8000 can be imported.
*7 Connecting instruments and collecting data with multiple launches of the IS8000 software on the same PC is not covered by the specification.
*8 MB1 option is required.
*9 G7 option on the connecting WT5000 is required to display measurement data complying with IEC 61000-4-7 Annex B (2k-9kHz).
*10 Firmware version 3.61 or later and the G7 option are required on the connected WT5000 to display interharmonic measurement data compliant with IEC 61000-4-7 Ed. 2.1 Annex A.
*11 Will be supported by the future update.
Classic Data Viewer is available at no extra charge on PCs with a valid IS8001/IS8002 license activated.
DL950将混合信号示波器和便携式数据采集记录仪结合为一个平台,可捕获高速瞬态事件和长期趋势,并能进行高达200MS/s和16位A/D的高速多通道测量。为了实际应用可组合超过20种不同的模块,单台仪器即可测量从低压到1000V绝缘模拟信号、逻辑信号、车辆通信信号、振动和应变量、温度等各种信号。它还可以将车辆通信数据(例如CAN/CAN FD/LIN/SENT)显示为趋势波形。 12.1英寸大尺寸触摸屏可实现直观的操作。新设计的应用菜单让常用应用的设置变得更加简单。通过将DL950与IS8000结合使用,可以在测量时将数据直接传输到PC,在PC上进行分析。最多可以有5台DL950通过光纤同步,同时测量多达160个通道。了解更多示波器DL950的信息
WT5000是一款高精度功率分析仪,其基本功率精度为±0.03%,是世界上最优秀的功率分析仪之一。 WT5000具有±0.07%的DC功率精度、 10MHz的电压测量带宽、 5MHz的电流测量带宽以及(视在功率) ±0.02%的低功率因数特性,可对设备功耗、损耗和转换效率进行高精准测量。多达7个功率输入和4个电机扭矩输入,可同时评价多个电机驱动系统。 WT5000可帮助提高EV、 HEV、可再生能源相关设备和节能型家电的开发效率。 了解更多高精度功率分析仪 WT5000的信息
The DLM5000HD is a compact eight-channel 12-bit oscilloscope with the ability to observe and analyze complex high-speed waveforms in high resolution, making it easy to check fine noise, ringing, and other details. The intuitive touchscreen, auto setup, and extensive analysis functions accelerate complex diagnosis, providing unparalleled testing precision.Click here to learn more about the DLM5000HD Series High-Definition Oscilloscope.
*1 Only one unit
*2 Limited functions
*3 "DLM5000" includes DLM5000HD series.
Compatible high-speed cameras for online synchronization:
Photron FASTCAM SA-Z、MIni UX*2/AX/WX series, NOVA S series, NOVA R2
*1 "DLM5000" includes DLM5000HD series.
*2 Pre-trigger recording and multi-trigger recording using the Mini UX series in combination with the FS1 option are not supported.
电机效率是电动汽车的一项关键指标,因为小幅改进就可能会增加行驶里程。效率测量需要用电机转速和扭矩进行准确的同步功耗测量。
实现功率分析仪和高速记录仪的高精度同步测量
使用IEEE1588 PTP技术,可以将来自WT5000功率分析仪和DL950示波记录仪的数据进行时间同步,且误差小于10μs。在同一时间轴上即可显示精确的功率参数和波形。
为了分析电动机和变频器系统,需要三相之间的电压和电流信号,电机I/O信号以及多个IGBT门信号来正确地测量和诊断系统性能和效率。
组合更多波形
测量负载系统中的变频器性能需要超过8个波形。 IS8000可以连接多台8通道DLM5000示波器,满足在一个控制和观测界面中显示和分析所有通道的需求。
风能、太阳能和水力等可再生能源系统必须保持能量转换阶段的高效率,以减少对环境的影响。多个测量点的精准和同步尤为重要。
查看和比较多台仪器的波形
IS8000可轻松同步多台仪器的波形,生成一个易于比较的视图。使用缩放和平移控制可轻松完成波形操作,用于分析长时间记录的能量波形
对于具有成本效益的制造系统,需要对机器人焊接条件进行优化。要确定机器人的姿态和性能之间的最佳组合,需要监测多个信号和输入(包括高速摄像机输入、源电压和电流以及多个位置和控制I/O信号)。
同时记录多种信号类型
IS8000可显示多个输入。摄像机图像在时间上与其他波形(包括控制信号以及电压和电流波形)对齐。同时慢动作回放实现了设计和结果之间的可视化。
This licenses type is based on annual subscription renewal for the platform and optional features. Users can purchase the software for as long as they need it, keeping their initial investment to a minimum. Users will always have the latest version of the software available for the duration of the subscription, so they will always be able to use the latest features, standards and security.
This is a one-time purchase and can be used indefintely. Additional optional features can be purchased at a later date. The platform can be upgraded free of charge for up to five years major software version revisions after purchase. After that, users can continue to use the software in the same environment. This license is suitable for users who do not plan to change their equipment environment at the time of installation.
All IS8000 models and licenses, except the free trial period, require software activation over the internet before use. If the PC with the IS8000 installed cannot be connected to the network, it is possible to activate the IS8000 via another network-accessible PC. For more information, please refer to the electronic manual.
ANIS8000APP02-01EN
ANIS8000APP04-01EN
Detailed measurement methods, supply voltage settings, and others are specified for the harmonic/flicker standard test.
本视频为大家介绍IS8000软件集成平台一个非常有用的功能,波形缩放功能。
利用WT5000的波形数据流功能,将波形数据流输出到上位机,并借助IS8000软件强大的波形分析功能对功率分析仪输出的波形进行深入分析。
IS8000软件平台是一个加速工作流程的集成解决方案。它是一款革命性的软件,紧密集成了多个仪器的计时、控制和数据收集,创建了一个全面的测量套件,使测试工作更高效率、可靠和统一。
Test and measurement engineering work groups can have differing priorities and requirements, which often results in multiple instrumentation systems and data file formats, as well as incompatible reporting. This lack of effective communication between groups and instruments causes decreased efficiency and quality and increased spending and time to market. Unify test and measurement instrumentation, software, and data across engineering teams with a suite of solutions that caters to the different needs of engineering work groups, including accurate power data, fast sampling rates, long recordings of multiple different input types, and insights into waveform data.
Looking for a turnkey high-speed data transfer solution with better bandwidth and minimal manual overhead?
The 10Gb Ethernet option on the Yokogawa Test&Measurement DL950 ScopeCorder fits that very role and makes capturing and recording high-speed data seamless and convenient.
Record data at 50 times the speeds of traditional Ethernet and USB connections and automatically transfer data to your PC in a single step using the IS8000 Integrated Software Platform.
The multi-unit synchronization option for the Yokogawa Test&Measurement DL950 ScopeCorder lets you time synchronize up to five DL950 ScopeCorders, for up to 160 channels of voltage, current, temperature, strain measurements, and more. This video walks you through how to set up and connect the multiple DL950 ScopeCorders, take measurements, and pull the data from all of the instruments for analysis with the IS8000 Integrated Test and Measurement Software Platform.
Having multiple memory options allows engineering groups to optimize how data is stored, no matter if you need to record for a long time at slower sampling rates, do a fast capture at high sampling rates, or anything in between.
The Yokogawa Test&Measurement DL950 ScopeCorder operates as an oscilloscope and incorporates the ability to record data for long periods of time like a data acquisition recorder. There are four memory types on the DL950 ScopeCorder: internal memory, solid state drive, flash memory, and PC storage through the IS8000 Integrated Test and Measurement Software Platform. This videos talks about the advantages of each of these and how to pick the best data recording method for you.
With ongoing innovations in motor and inverter technologies seeking to advance global decarbonization objectives in the automotive industry, it’s crucial that engineers have a thorough understanding of how to properly analyze these systems.
This complimentary webinar provides engineering professionals involved in motor and control system development with insights that enable data benchmarking and troubleshooting issues related to energy efficiency in electric vehicle (EV) powertrains.
Key webinar topics include: