Yokogawa数据采集系统具备出众的灵活性和性能,能测量、显示、存储甚至促动各种物理和电气现象。高速DAQ系列在每个通道提供行业领先的信号调节、触发器、同步采样和码流。数采在工业记录仪非常适合多通道的静态、低速I/O记录,例如热电偶和压力传感器。示波记录仪集示波器和DAQ系统的优点于一身,采用巧妙的台式接口组装设计。
我们的示波记录仪是灵活、强大的多通道测试和测量解决方案,将高精度示波器和传统有纸图表记录仪的优点集于一身。Yokogawa的示波记录仪除了能在它的大显示屏上显示信号之外,还可以将信号保存到记录纸和/或存储介质中以便长期储存(如30天或更长),此外它还可以捕捉并分析非常快的瞬变信号。
YOKOGAWA的高性能数据采集和记录系统,以及各种有纸和无纸记录仪能够满足您的不同记录需求。通用输入接受电压、热电偶和RTD信号,并能为记录跨度和单位标度提供最大的灵活性。
侧面碰撞安全气囊的正时测试
DL950_Switched_Mode_Power_Supply_Output_Monitoring
DL950_Design_and_Evaluation_of_the_Electric_Power_Steering_EPS
DL950_Evaluation_of_ECU_and_InverterMotor
ABS动作期间的电池电压波动
DL950_Comprehensive_evaluation_of_vehicle_systems_using_real_signal
How to use built-in calculations to analyze motor rotor position and find the relative angle between the rotor and sensors such as encoders or resolvers.
How can I capture data from motion sensors synchronized with other analog data? The Yokogawa ScopeCorder series of instruments feature input modules and functions to make this possible.
感谢大家一直以来对横河产品的支持, 现通知下列便携式无纸记录仪自 2016-10-24 开始停止接受订单。
《应用探索》是一份电子快讯,每两个月发布一期,向客户通报我们最新的新闻和产品应用。
在经过2009年灾难之后,很多上市的测试仪器公司业务在2010年取得了高速增长。
When making a WT230 RS232C connection using GateWT, please verify the following RS232C communication settings on the instrument: Mode = 488.2 Hand = 0 For = 0 Baud Rate = 9600 Terminator Cr+Lf Even though you can run ...
Unfortunately, we do not have an instruction manual describing the*.WDF file format structure like we did for the *.WVF files. However, we do provide a list of support options which will contain more details ...
The external trigger input (TRIG IN) as well as external input/output (EXT. I/O) trigger signal becomes the level signal. The WE7251/WE7271 digitizer module will detect the bus trigger by that level. As long as the ...
In the oscilloscope's QIS (Quality Inspection Standards), the "beat method" can be used to inspect and verify the time base accuracy. The "beat method" utilizes the aliasing effect to create a "beat waveform." The "beat ...
Unfortunately there is no way to read these warning messages on the DL750. In addition, there is no other command available to determine if there was "No Matching Record" found in History for a particular ZONE ...
Error(Code:539)Press ESC Key to Close.Module configuration is not matched, so it couldn’t loaded.Configuration of saved data can see by File property.The following error is ...
No, this "calibration" does not refer to the ScopeCorders Auto-Cal feature. When the Auto-Cal function is set to OFF, the ScopeCorder will not automatically calibrate after a 30 minute warm-up period. You must do a ...
My DL750 HDD RECORDING "REALTIME" Files are missing. Please help. (Or: You need to locate them and move them to my PC via USB THUMB DRIVE.) DL750 REALTIME FILES ".WDF Files" are not visible on the DL750 HDD ...
轻松应对超高级标准的温度测试,智能化的横河SMARTDAC+ GP便携式数据采集站值得信赖。
Using the DL350 Memory Recorder Mode Easy Setup, combined with a 16-channel thermocouple input, it's easy to record hours, days, or weeks of data with a few simple settings.