How to Setup an Optical Spectrum Analyzer

Learn how to properly set up an Optical Spectrum Analyzer (OSA) for accurate and reliable optical measurements.

In this video, you'll learn:

  • How to transport and install an Optical Spectrum Analyzer
  • Instrument alignment and adjustment procedures
  • Wavelength calibration techniques
  • Best practices for preparing your OSA before measurement

Whether you're working in optical communications, photonics research, or fiber optic testing, proper OSA setup is critical to achieving precise measurement results.

Explore Yokogawa Optical Spectrum Analyzer Solutions

Related Products & Solutions

AQ6361 Telecom Production 1200 - 1700 nm

  • 0.03 nm resolution
  • ±20 pm accuracy
  • 65 dB close-in dynamic range
  • -80 dBm level sensitivity
  • Highest sweep speed
  •  

AQ6370 Optical Spectrum Analyzer

  • Yokogawa AQ6370 Optical Spectrum Analyzer
  • Re-defining Optical Spectrum Measurement Excellence

AQ6370E Telecom 600 - 1700 nm

  • 0.02 nm resolution
  • ±8 pm accuracy
  • 78 dB close-in dynamic range
  • -90 dBm level sensitivity
  • Single-mode and multi-mode

AQ6373E Visible Wavelength 350 - 1200 nm

  • 0.02 nm resolution
  • ±50 pm accuracy
  • 60 dB close-in dynamic range
  • -80 dBm level sensitivity
  • Single-mode and multi-mode
  • Industrial & biomedical laser testing

AQ6374E Wide Wavelength Range 350 - 1750 nm

  • 0.05 nm resolution
  • ±50 pm accuracy
  • 60 dB close-in dynamic range
  • -80 dBm level sensitivity
  • Single-mode and multi-mode
  • Visible to communications wavelengths

AQ6375E Long Wavelength 1000 - 2500 nm

  • 0.05 nm resolution
  • ±50 pm accuracy
  • 55 dB close-in dynamic range
  • 90 dB measurement dynamic range
  • -70 dBm level sensitivity
  • Single-mode and multi-mode
  • Advanced pulsed light measurement (APLM) mode

AQ6376E Three Micron 1500 - 3400 nm

  • 0.1 nm resolution
  • ±0.5 nm accuracy
  • 55 dB close-in dynamic range
  • 78 dB measurement dynamic range
  • -65 dBm level sensitivity
  • Single-mode and multi-mode
  • Advanced pulsed light measurement (APLM) mode
  •  

AQ6377E Five Micron 1900 - 5500 nm

  • 0.1 nm resolution
  • ±0.5 nm accuracy
  • 50 dB close-in dynamic range
  • 73 dB measurement dynamic range
  • -60 dBm level sensitivity
  • Single-mode and multi-mode
  • Advanced pulsed light measurement (APLM) mode
  •  

AQ6380 Highest Performance 1200 - 1650 nm and 900 - 1650 nm

  • 0.005 nm (5 pm / 0.624 GHz) resolution
  • ±5 pm accuracy
  • 67 dB dynamic range
  • -85 dBm level sensitivity
  • O, C, and L-bands

Optical Spectrum Analyzers

  • High-resolution measurement of optical power vs wavelength
  • Ideal for R&D, manufacturing, and laser characterization
  •  

Precision Making

Top