DL7100/DL7200 Digital Oscilloscope (DISCONTINUED)

Notice: This product was discontinued on Sep 1, 2004. See this replacement product:

B9852MJ Power Cable for Differential Probes

  • B9852MJ power probe extension cable
  • Supplies power to 700924, 700925, and 701921 differential probes from the DL probe power connectors
  • Required on DL unit
  • Only works with newer probes

B9852ES Logic Probe IC Pin Clips

  • B9852ES Logic Probe IC Pin Clips
  • Attach to tips of logic probe (701988 or 701989) or mini-clips (B9852CR)
  • Clip contiguous 0.5-mm pitch terminals
  • 10 clips included

B9969ET Soft case for the DL7400 series

Ideal for storing accessories (probes, etc).

366924 BNC to BNC 1m Cable

  • 366924 BNC to BNC cable for oscilloscope 
  • 1m BNC wire
  • Simultaneous measurement with 2 units
  • Input external trigger signal

366925 BNC to BNC 2m Cable

BNC-BNC 2m. For connection to simultaneously measurement with 2 units, or for input external trigger signal.

700924 Differential Probe 1400V / 100 MHz

  • Differential oscilloscope probe
  • 100 MHz
  • ±1400 V (DC + ACpeak) at 1000:1
  • Internal battery or probe power supply
  • Oscilloscopes, ScopeCorders

700925 Differential Probe 500V / 15 MHz

Works with Oscilloscopes, ScopeCorders. 15 MHz, 100:1/10:1, Max. Differential Voltage: ±500 V (DC + ACpeak) or 350 Vrms at 100:1 attenuation, Probe Power: Internal battery or probe power supply.

700939 Active FET Probe 10V / 900 MHz

  • 700939 Active FET Probe
  • 900 MHz Active FET Probe Circuit
  • 10:1, ±10 V (DC + ACpeak) FET Input Active Probe
  • 1.5 m

 

700988 Passive Probe 400 MHz

400 MHz, 10:1/1:1, 600 V (DC + ACpeak) or 424 Vrms CAT II, 1.5 m For DL1700, DL1700E, DL7200, DL7400 series

701920 Differential Probe 12V / 500 MHz

  • 701920 Oscilloscope Differential Probe
  • DC to 500 MHz
  • 10:1
  • Max. Input Voltage:(to ground) ±40 V (DC + AC peak)
  • Max. Differential Voltage ±12 V (DC + ACpeak)
  • Probe power supply
  • 50 Ω input system oscilloscope

701921 Differential Probe 700V / 100 MHz

100 MHz, 100:1/10:1, Max. Differential Voltage: ±700 V (DC + ACpeak) at 100:1 attenuation, Probe Power: Internal battery or probe power supply

701922 Differential Probe 20V / 200 MHz

200 MHz, 10:1, Max. Differential Voltage: ±20 V (DC + ACpeak), Probe Power: probe power supply. Works with 50 Ω input system oscilloscope.

701926 Differential Probe 7000V / 50 MHz

50 MHz, 1000:1/100:1, Max. Differential Voltage: 5000 Vrms/7000 Vpeak (1000:1), Probe Power: Internal battery or probe power supply B9852MJ power cable is bundled Work with Oscilloscopes, ScopeCorders

701930 Current Probe 10 MHz / 150 ARMS

  • 701930 Current Probe 10 MHz / 150 ARMS
  • Powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply

701931 Current Probe 2 MHz / 500 ARMS

  • 701931 Current Probe 2 MHz / 500 ARMS
  • Powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply

701932 Current Probe 100 MHz / 30 ARMS

  • 701932 Current Probe 100 MHz / 30 ARMS
  • Powered by Yokogawa Digital Oscilloscopes, Scopecorders, or external power supply

701933 Current Probe 50 MHz / 30 ARMS

  • 701933 50 by 30 current probe
  • Powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply

701944 High Voltage Passive Probe 1000Vrms / 400 MHz

  • 701944 High Voltage Passive Probe 1000Vrms / 400 MHz
  • For DL1700, DLM2000-6000, DL6000, DL9000, SB5000 series

701945 High Voltage Passive Probe 1000Vrms / 250 MHz

  • 3m High Voltage Probe (oscilloscope)
  • DC to 250 MHz bandwidth 
  • 100:1 attenuation 
  • Max Input 1000 Vrms CAT II 4000 V transient over-voltage CAT I

701934 External Probe Power Supply

  • 701934 External Probe Power Supply
  • Power supply for current probes, FET probes, and differential probes
  • Supplies power for up to four probes, including large current probes

701919 Probe Stand

  • 701919 oscilloscope probe stand
  • Flexible arm, heavy base to hold and stabilize 8-13mm probes
  • Can simplify circuit board testing

366923 BNC to T Adapter

T-adapter for BNC connectors. Use for circuits having voltage levels no greater than 42 V.

Looking for more information on our people, technology and solutions?


Contact Us

Precision Making

Top