This high-voltage differential probe features a wide frequency range from DC to 400 MHz, excellent frequency response flatness, and superior Common Mode Rejection Ratio (CMRR) characteristics.
| 
			 Bandwidth  | 
			
			 DC to 400 MHz  | 
		|
|---|---|---|
| 
			 Attenuation  | 
			
			 500:1/50:1  | 
		|
| 
			 Max. Input Voltage (to Ground)  | 
		||
| 
			 ±1000 V (DC + ACpeak)  | 
		||
| 
			 Max. Differential Voltage  | 
		||
| 
			 ±1000 V (DC + ACpeak) at 500:1 attenuation  | 
		||
| 
			 Max. Non-Destructive Input Voltage  | 
		||
| 
			 ±1500 V (DC + ACpeak) (within 5 seconds)  | 
		||
| 
			 Probe Power  | 
			
			 Dedicated probe interface  | 
		|
| Frequency Band | DC to 400 MHz (-3 dB) | 
|---|---|
| Input Attenuation Ratio | 50:1 and 500:1, User Selectable | 
| Input Impedance (to Ground) | Approximately 6 MΩ, Approximately 5 pF | 
| Maximum Allowed Differential Voltage | ±1000 V (DC + ACpeak) (500:1) ±100 V (DC + ACpeak) (50:1)  | 
		
| Maximum Common Mode Input Voltage (to Ground) | ±1000 V (DC + ACpeak) | 
| Maximum Non-Destructive Input Voltage (to Ground) | ±1500 V (DC + ACpeak) (within 5 seconds) | 
| Common Mode Rejection Ratio (CMRR) (Typical) | -80 dB (60 Hz), -50 dB (10 MHz), -30 dB (100 MHz), -20 dB (400 MHz)  | 
		
| Connector Type | BNC | 
| External Dimensions (Approximate) | Head: 173.5 (H) × 58 (W) × 26.5 (D) mm Connector: 46.5 (H) × 30 (W) × 17 (D) mm  | 
		
| Total Length | Approximately 2.4 meters | 
| Weight | Approximately 300 grams | 
| Measurement Category | CAT II 1000 V, CAT III 600 V |