This high-voltage differential probe features a wide frequency range from DC to 400 MHz, excellent frequency response flatness, and superior Common Mode Rejection Ratio (CMRR) characteristics.
Bandwidth |
DC to 400 MHz |
|
---|---|---|
Attenuation |
500:1/50:1 |
|
Max. Input Voltage (to Ground) |
||
±1000 V (DC + ACpeak) |
||
Max. Differential Voltage |
||
±1000 V (DC + ACpeak) at 500:1 attenuation |
||
Max. Non-Destructive Input Voltage |
||
±1500 V (DC + ACpeak) (within 5 seconds) |
||
Probe Power |
Dedicated probe interface |
Frequency Band | DC to 400 MHz (-3 dB) |
---|---|
Input Attenuation Ratio | 50:1 and 500:1, User Selectable |
Input Impedance (to Ground) | Approximately 6 MΩ, Approximately 5 pF |
Maximum Allowed Differential Voltage | ±1000 V (DC + ACpeak) (500:1) ±100 V (DC + ACpeak) (50:1) |
Maximum Common Mode Input Voltage (to Ground) | ±1000 V (DC + ACpeak) |
Maximum Non-Destructive Input Voltage (to Ground) | ±1500 V (DC + ACpeak) (within 5 seconds) |
Common Mode Rejection Ratio (CMRR) (Typical) | -80 dB (60 Hz), -50 dB (10 MHz), -30 dB (100 MHz), -20 dB (400 MHz) |
Connector Type | BNC |
External Dimensions (Approximate) | Head: 173.5 (H) × 58 (W) × 26.5 (D) mm Connector: 46.5 (H) × 30 (W) × 17 (D) mm |
Total Length | Approximately 2.4 meters |
Weight | Approximately 300 grams |
Measurement Category | CAT II 1000 V, CAT III 600 V |
To best utilize SiC devices for improved energy efficiency in equipment, it is important to optimize the internal device peripheral circuits in the inverter according to the device characteristics.