With three available models to meet the demands of various applications, this versatile OSA accelerates the development and manufacturing of short wavelength lasers, passive devices, and LEDs, as well as equipment that use these devices for the biomedical, material processing, consumer product, and telecommunications markets. 

AQ6373E Visible Wavelength Optical Spectrum Analyzer

  • Three available models for short wavelength range applications: Standard, High Resolution, Limited
  • Wavelength Range: 350 - 1200 nm (all models)
  • Wavelength Resolution
    • Standard: 0.02 nm - 10 nm
    • High Resolution: 0.01 nm - 10 nm (0.01 nm from 350 - 600 nm)
    • Limited: 0.1 nm - 5 nm
  • Wavelength Accuracy
    • Standard: ±0.05 nm (633 nm), ±0.2 nm (400 - 1100 nm)
    • High Resolution: ±0.05 nm (633 nm), ±0.2 nm (400 - 1100 nm)
    • Limited: ±0.05 nm (633 nm), ±0.2 nm (400 - 1100 nm)
  • Close-In Dynamic Range
    • Standard: 60 dB (λPK ± 0.5 nm) 
    • High Resolution: 60 dB (λPK ± 0.5 nm)
    • Limited: 45 dB (λPK ± 0.5 nm) 
  • Sensitivity
    • Standard: -80 dBm (500 - 1000 nm)
    • High Resolution: -80 dBm (500 - 1000 nm)
    • Limited: -70 dBm (500 - 1000 nm)
  • Measurement Level Range
    • Standard: 100 dB (-80 - +20 dBm)
    • High Resolution: 100 dB (-80 - +20 dBm)
    • Limited: 90 dB (-70 - +20 dBm)
  • Max Safe Input Power: +20 dBm (550 to 1100 nm) +10 dBm (400 to 550 nm) (total input power)
  • Single-mode, multimode, and large-core fibers
  • Built-in optical alignment source
  • Wavelength calibration with an external reference source
  • Various analysis functions including color analysis for VIS

World-Class Optical Performance

High Resolution & High Dynamic Range
The advanced monochromator achieves high wavelength resolution and high close-in dynamic range. With the sharper spectral characteristics of the monochromator, spectral signals in close proximity can be separated clearly and measured accurately.

High Sensitivity
Weak optical signals can be measured accurately and quickly.

Seven Sensitivity Settings*
The sensitivity settings can be selected according to test applications and measurement speed requirements.
*Except Limited Model

High Dynamic Mode
The dynamic range can be improved by reducing the influence of stray-light, which is caused when the input is a strong optical signal.

Peak-Hold & External Trigger Mode
The pulse peak spectrum of a pulsed light signal is measurable. Often used in the transmission loop testing of telecommunication systems, and also in the low power measurement at the early stage of laser chip development to catch the peak power of a pulsed signal.

Free Space Input
Free space input enables multimode and single-mode fiber on the same OSA and small insertion loss variation at the input connector increases measurement repeatability. Because there is no physical contact, no damage results when connecting fibers. This feature supports SM, GI (50/125 μm, 62.5/125 μm), and large core fiber up to 800 μm.

Free-Space Input | Optical Input Structure | Optical Spectrum Analyzer | Yokogawa Test&Measurement
Optical Input Structure

Fast Sweep
With an advanced monochromator, faster electrical circuits, and noise reduction techniques, the AQ6373E achieves fast measurement speed even when measuring a steep spectrum from DFB-LD signals, or when measuring a low power signal from a broadband light source.

Wide Span Sweep with High Resolution
The 200,001 data sampling points expand measurement range in a single sweep while keeping a high wavelength resolution. This makes your measurements easier and more efficient than conventional systems that use a low number of sampling points and require multiple partial measurements to cover the complete wavelength range.

Easy Accuracy Maintenance
Ambient condition change, vibration, and shock to an optical precision product, like an optical spectrum analyzer, will effect the optical components and eventually degrade optical performance. Using standard functions, the AQ6373E can maintain its high optical performance within a couple of minutes to enable quick-start measurements.

Optical Alignment
Automatically align the optical path in the monochromator using the built-in source to maintain high performance.

Wavelength Calibration
Automatically calibrate the optical spectrum analyzer with an external light source to ensure the wavelength accuracy.

Built-In Optical Alignment Source
An external light source is needed for wavelength calibration. GI 50/125µm fiber required along with periodic calibration. In some instances, the optical alignment and wavelength calibration function cannot correct optical performance.

Thumbnail File Preview
Easily locate specific files out of thousands in internal and external storage.

Thumbnail View | AQ6373E OSA | Yokogawa Test&Measurement

USB Ports
Four USB ports facilitate the use of external devices such as a mouse, keyboard, external hard drives, and memory sticks.

Large touchscreen LCD
A responsive high-resolution 10.4-inch multi-touch capacitive touchscreen makes device operation even simpler and more intuitive. Change measurement conditions, perform analysis, and change the optical spectrum view as if you were operating a tablet device. In the optical spectrum view, the waveform view can be zoomed or shifted by a simple tap and drag.

Advanced Marker
Adds markers to obtain the power density and the integrated power of a designated spectrum.

Spectrum Analysis
Multiple data analysis functions are available that cover many popular applications:

  • OSNR
  • DFB-LD
  • FP-LD
  • LED
  • SMSR
  • Color Analysis
  • Various Filters
  • Optical Power
  • Spectral Width
     

Seven Individual Traces
Users can directly select the trace using a mouse via simultaneous multi-trace display and employ Max/Min hold and calculation (subtraction) between traces.

Built-In Macro Programming
Create automated test systems to perform automatic measurements and control external equipment through a remote interface. GP-IB, and Ethernet (10/100Base-T) ports are available for remotel control via PC and to transfer standard SCPI-compatible (ASCII code, conforms to IEEE-488.2) or proprietary AQ6317-compatible commands (Emulation Mode). LabVIEW® drivers are also available.

DUT-Oriented Test Apps (APP)
Application (APP) mode simplifies the testing process by transforming the AQ6373E OSA into a machine dedicated to a device under test (DUT). APP mode provides a DUT-specific user interface that navigates from configuration settings to test result output without the need to worry with many of the other OSA settings. The AQ6370 Series includes multiple pre-installed basic applications such as WDM, DFB-LD, and FP-LD testing. The application is also availble to download from the Yokogawa Test&Measurement website.

DUT-Oriented Test Apps (APP) | AQ6373E OSA | Yokogawa Test&Measurement

The AQ6373E optical spectrum analyzer is perfect for a variety of applications including:

  • Optical active devices(laser diode/fiber laser)
  • Optical passive devices(filter/FBG/specialty optical fiber)
  • Development support of applied photonics equipment
  • Medical/Bio: Laser therapy, DNA sequencing, microscope
  • Industrial: Laser micro-machine, laser maker
  • Home Electronics: Laser projector, next-gen optical disc, LED products
  • Measurement Sensing: LiDAR, interferometer
  • Telecomm: Plastic optical fiber (POF) communication

Visible LED Test
Supporting the large core fiber input, the AQ6373E OSA and AQ6374E OSA efficiently attain visible LED light from lighting, signage, sensing, and other applications and measures its spectrum.The built-in Color Analysis function automatically evaluates the dominant wavelength and the chromatic coordinates of the source.

Example of Color Analysis with AQ6374E OSA | Yokogawa Test&MeasurementExample of Color Analysis with AQ6374E

Analysis of Visible Lasers
Visible lasers are mounted into many different devices/systems used in a variety of applications such industrial (barcode scanners, LiDAR surface scanners), consumer electronics (Hi-Fi audio systems audio output, laser printers, computer mice), and automotive/home networking (plastic optical fibers cabling).

Example of Visible Laser Measurement with High-Resolution Model | AQ6373E OSA | Yokogawa Test&Measurement
Example of Visible Laser Measurement with High-Resolution Model
VCSEL
VCSEL seen through a Scanning Electron Microscope

Numerical Aperture Conversion Fiber

By connecting a GI 50 or GI 62.5 optical fiber with a relatively large NA to the NA Conversion Fiber, the NA Conversion Fiber reduces the loss that occurs at the input and improves the measurement dynamic range during passive device measurements and the stability of optical level measurements during active device measurements.

751535-E5 Rack mounting kit

RACK MOUNTING KIT For an EIA-compliant Single-housing Rack

Overview:

To accurately measure pulsed light using an optical spectrum analyzer (OSA), it is necessary to understand the characteristics of the OSA and select the appropriate measurement method and settings.

Overview:

This application note introduces free space light measurement jigs for measuring the emission spectrum of a light source that propagates in free space or the optical transmission spectrum of an optical filter. It describes four types of jigs for light sources and one type for filters.

Application Note
Overview:

OSA Macro Program Function

The OSA Macro Program Function enables automated measurement by creating programs for entry of measurement conditions and other tasks. Users can program a sequence of measurement procedures from entry of measurement conditions (e.g., wavelength sweep width, setting resolution) to analyses, data saving, output, and others and eliminates redundant procedures on the production line. The function acts as a controller of other connected devices through the LAN or RS232C port and allows users to build an automatic measuring system without using an external PC and input measurement conditions or output measured results while programs are running.

Product Overviews

Webinars

    Overview:

    There are countless technologies available for optical communications devices and systems validation. With so many specifics to take into consideration, it's not always easy for an engineer to determine the best networking and fiber optic measurement solution to address their measurement needs.

    Key discussions in this on-demand webinar include:

    • The what, why, and how of available options like optical spectrum analyzers, optical wavelength meters, optical power meters, variable attenuators, fixed and tunable laser sources, and more
    • How to improve the quality and value of results for both active and passive optical devices
    • Ways to streamline productivity and reduce costs while also achieving higher data transmission rates, longer-distance transmissions, immunity to EMI, lower signal loss, lower latency, enhanced security, and improved energy efficiency
    • Trends driven by applications such as AI, quantum, and inter-satellite laser communications (i.e., space lasers!)
    Overview:

    Mastering the fundamentals of optical wavelength measurements and having a solid understanding of measurement principles for optical sources and devices is key to measuring with confidence. This webinar provides a thorough review of these foundational elements and concepts as well as:

    • Fiber identification and recommendations for routine care
    • Measurement techniques for different optical measurement devices
    • Example wavelength-specific applications for visible light to over 3000 nm such as telecommunications, biomedical, and atmospheric gas sensing
    • Important considerations for selecting an optical spectrum analyzer

Looking for more information on our people, technology and solutions?


Contact Us

Precision Making

Top