High-speed 10 MS/s 16-Bit isolation module (4 channels) – High noise immunity. Suitable for testing and longterm monitoring for power generators and multi-output power supplies. Provides dynamic analysis of multi-channel data recording applications. For use with the DL950 ScopeCorder.
Max. sampling rate: 10 MS/s
A/D conversion resolution: 16 bit
Number of channels: 4
Max. input voltage (DC + ACpeak): 600V / 200V
High-Speed 100 MS/s 12-Bit Isolation Module (2 channels)
IsoPRO technology enables 1kV isolated measurements in combination with 700929 or 701947 probe and is designed for inverter / IGBT related applications in mind. Using high speed optical fiber-based transmission, the module achieves high speed ADC clock and data isolation and provides the performance needed to develop high efficiency inverters, which employ high voltages, large currents, and ever increasing switching speeds.
Applicable to DL350, DL850 series, DL950 and SL1000.
High-Speed 10 MS/s 12-Bit non-isolation Module (2 ch)
Non-Isolation version of model 720250
Applicable to DL350, DL850 series, DL950 and SL1000.
Temperature/high-precision voltage Module (2 ch)
Thermocouple (K, E, J, T, L, U, N, R, S, B, W, iron-doped gold/chromel), high sensitivity range (1 mV), and low noise (±4 µVtyp)
Applicable to DL350, DL850 series, DL950 and SL1000.
Strain Module with Shunt Calibration, type DSUB (2 channels) to be used in combination with 701957 or 701958 DSUB bridge head.
Using the strain module and strain gauge the ScopeCorder can detect and display mechanical stress (strain). It works on the principle that the resistance value of a metal foil changes as it expands and contracts.
Applicable to DL350, DL850 series, DL950 and SL1000.
Use the SENT monitoring module to decode the SENT protocol signal and display information on physical quantities from SENT output sensors.
Applicable to DL850V & DL850EV, DL350 (/VE option), DL950 (/VCE option) ScopeCorder Vehicle Edition only.
Passive Probe, 1000V(DC+ACpeak) CAT II, 60MHz, 10:1, 10MΩ, 2.5m
Wide operating temperature range(-40 to 85°C)
For isolated BNC input modules for ScopeCoder series
The 720930 and 720931 passive clamp-on current probes allow current waveform readings directly via analog input modules on ScopeCorders including the DL350 and DL850 using isolated BNC connections.
The 720931 passive clamp-on current probe anables current waveform readings directly via analog input modules on ScopeCorders including the DL350 and DL850 using isolated BNC connections.
8-bit, non-isolated, response speed: 1µs, threshold level approx 1.4V
Two measurement leads (B9879PX and B9879KX) included.
8-bit, non-isolated, response speed: 3µs or less, treshold level approx 1.4V
702911: 1 meter cable, 702912: 3 meter cable
For the DC power supply model (/DC). Cigarette lighter plug type.
T-adapter for BNC connectors. Use for circuits having voltage levels no greater than 42 V.
Safety-terminal-binding-post adapter. Use for circuits having voltage levels no greater than 42 V.
For conversion between BNC and female banana plug
Applicable for DL750/DL750P, SL1000 & SL1400.
2 pieces (red and black) in 1 set
length: 1.00 m
Used in combination with the 701959, 758921, 758922, or 758929
Rating: 1000 V CAT III/19 A
Set contains one black and one red clip
1000 Vrms-CAT II
2 pieces (red and black) in 1 set
Connected to the 758933, 758917, or 701901
Length: 0.3m
Applicable for DL750/DL750P, SL1000, SL1400
Connected to the 700929, 701947
Maximum input voltage: 1,000V (DC + ACpeak)
Length: 0.26m/0.3m/0.4m
Applicable for DL750/DL750P, SL1000, SL1400
Set contains one black and one red clip.
1000 Vrms-CAT II.
Rated at 300 V. Attaches to the 758917 test leads. Sold in pairs.
Screw-fastened adapters. Two adapters in a set. 1.5 mm Allen Wrench.
BNC-BNC 2m. For connection to simultaneously measurement with 2 units, or for input external trigger signal.
A subassembly of 1.2 m long test leads with alligator-clip adapters.
Use only for circuits having voltage levels no greater than 42 V.
Applicable for SL1000 & SL1400.
This is an AC Adaptor for the Portable DL350 ScopeCorder available for use in multiple global regions (North America adaptor pictured).
Frequency bandwidth: DC to 120 MHz
Maximum continuous input range: 0.5 Arms/5 Arms/30 Arms
Functions with Digital Oscilloscopes, ScopeCorders and other waveform measuring instruments
Maximum power point tracking (MPPT) charge controllers play a crucial role in the optimization of renewable energy system efficiency and performance. Through dynamic tracking of a renewable energy source’s maximum power point, an MPPT controller enables more efficient energy harvesting, faster charging, and adaptability to changing environmental conditions.
Designing an instrumentation system for high current measurement requires careful consideration of the trade-offs associated with each type of sensing device. The purpose of this application note is to help engineers understand the sensing choices available and the corresponding trade-offs with each technology.
In a research published in the SAE International Journal of Fuels and Lubricants, researchers from Georgia Southern University use a Yokogawa Test&Measurement DL850 ScopeCorder to record and monitor data from a piezoelectric pressure transducer in-cylinder, a pressure sensor for intake pressure, and an optical rotary encoder for engine rotational position and speed, and to test the combustion and emissions characteristics on an experimental engine.
In this research paper published by the Department of Mechanical Engineering at Georgia Southern University, researchers use a Yokogawa Test&Measurement DL850 ScopeCorder for real-time high-speed data acquisition on a research engine to investigate the low-temperature combustion regions of aerospace F24 and ULSD for emission reduction.
We developed an algorithm to optimize induction motor operation and produce an average power consumption savings of at least 10%. To demonstrate our algorithm’s effectiveness, we needed a proven and verified system that would give these results credibility. The solution provided by Yokogawa Test&Measurement enabled us to monitor and refine our algorithm using real-time speed, power, and temperature readings – data that would normally be incredibly difficult to accurately obtain. Having these real-world results that demonstrate the effectiveness of our algorithm means we can be more efficient with our own customers. —Neil Singer, President, AC Kinetics
It’s not an exaggeration to say I owe a good bit of my career success to Yokogawa Test&Measurement. By using their ScopeCorders that combine the best parts of an oscilloscope and DAQ, projects that once took weeks across multiple instruments suddenly only took a few hours with just one instrument. The impact on what I could accomplish really was quite remarkable, and my ability to accurately complete projects in record time made me look incredible. No matter how complex or convoluted the task, the ScopeCorders never fail to easily handle anything I throw at them. They’re amazing instruments and I tell others about them every chance I get. —Kenneth Shoemaker, Automotive Industry Consultant/Owner at Panama Prototypes
I’ve been using Yokogawa Test&Measurement instruments for power measurement and analysis for several years and they always get the job done. They provide extensive and thorough documentation for their equipment and their drivers are very handy. Features like screengrabs of test results for easier sharing and the remote interface (which minimizes the time we spend having to automate tests) have proven to be incredibly helpful. My team needs instruments that are well documented, easy to use, and reliable. Yokogawa instruments check all these boxes.
—Power Drive Systems Electrification Validation Test Development, Fortune 500 Leading Global Supplier of Sustainable Automotive Solutions
For standby power measurement and energy certification maintenance, we rely on Yokogawa Test&Measurement instruments. Their precision, accuracy, and ease-of-use are unrivaled. When given a choice between other test and measurement equipment and Yokogawa, our technicians always go for Yokogawa first. The support team provides thoughtful insights based not just on our industry but also our company’s specific needs. My team has used Yokogawa Test&Measurement instruments for decades and will continue to do so well into the future.
—Director of Technology Laboratories, International Multi-Brand Manufacturer of Major Home Appliances
When I started with my company almost 20 years ago, Yokogawa Test&Measurement instruments were already in use and the engineers had no intention of switching. In fact, we still routinely use some of the older instruments because, well, they just work! The equipment doesn't really become obsolete, and they support their instruments as long as is feasible, which ultimately saves us money. Even so, as things change in our industry Yokogawa adjusts to meet those changes. From our sales representative through technical support and more, I can count on the Yokogawa team to really listen and work with us to provide a specific solution for unique problems.
—Senior Lab Technology Engineer, EMI/EMC, Large Power Systems, Testing, Global Design of Commercial and Industrial Power, Cooling, and IT Infrastructure
Looking for a turnkey high-speed data transfer solution with better bandwidth and minimal manual overhead?
The 10Gb Ethernet option on the Yokogawa Test&Measurement DL950 ScopeCorder fits that very role and makes capturing and recording high-speed data seamless and convenient.
Record data at 50 times the speeds of traditional Ethernet and USB connections and automatically transfer data to your PC in a single step using the IS8000 Integrated Software Platform.
The multi-unit synchronization option for the Yokogawa Test&Measurement DL950 ScopeCorder lets you time synchronize up to five DL950 ScopeCorders, for up to 160 channels of voltage, current, temperature, strain measurements, and more. This video walks you through how to set up and connect the multiple DL950 ScopeCorders, take measurements, and pull the data from all of the instruments for analysis with the IS8000 Integrated Test and Measurement Software Platform.
Learn what signal types can be input into a scope using a Yokogawa Test&Measurement DL950 ScopeCorder, a unique combination of a 32-channel mixed signal oscilloscope and portable DAQ that captures both high-speed transient events and long-run trends.
We are going live on YouTube to answer your questions about the Yokogawa Test&Measurement DL950 ScopeCorder. Join us as we discuss how to make the most of this versatile instrument based on your application needs. Whether you’ve worked with a ScopeCorder for years or curious if it is a good fit for your engineering work group, this live stream can help.
Learn how to sync video data from a high-speed camera with data acquisition devices and scopes used by engineers in test and measurement applications.
Why should you be concerned with your product’s power system voltage and current harmonics? From an engineering perspective, harmonics produce excessive heat in equipment that causes significant damage and results in inefficient operation. From a business perspective, compliance is an absolute requirement for entry into global markets. To minimize or eliminate these issues and establish acceptable levels of harmonics, numerous power quality standards with specifications and limits for harmonic distortion, such as IEEE 519-2014 and IEC61000-3-2, have been introduced. During this webinar, attendees will gain knowledge on the inner workings of harmonics, learn best practices for accurately measuring harmonics, learn to recognize and distinguish the critical difference between DFT and FFT, and discover important measurement tradeoffs across various test equipment.