ScopeCorders Accessories

  • 720212 High-speed 200 MS/s 14-Bit Isolation Module
  • Max. sampling rate: 200 MS/s
  • A/D conversion resolution: 14-Bit
  • Max. input voltage (DC + ACpeak): 1000V / 200V

High-speed 10 MS/s 16-Bit isolation module (4 channels) – High noise immunity. Suitable for testing and longterm monitoring for power generators and multi-output power supplies. Provides dynamic analysis of multi-channel data recording applications. For use with the DL950 ScopeCorder.

Max. sampling rate:  10 MS/s
A/D conversion resolution:  16 bit
Number of channels:  4
Max. input voltage (DC + ACpeak):  600V / 200V

High-Speed 100 MS/s 12-Bit Isolation Module (2 channels) 
IsoPRO technology enables 1kV isolated measurements in combination with 700929 or 701947 probe and is designed for inverter / IGBT related applications in mind. Using high speed optical fiber-based transmission, the module achieves high speed ADC clock and data isolation and provides the performance needed to develop high efficiency inverters, which employ high voltages, large currents, and ever increasing switching speeds.
Applicable to DL350, DL850 series, DL950 and SL1000.

  • 720250 Voltage Module
  • 10 MS/s sample rate
  • 12-bit resolution
  • 3 MHz bandwidth
  • 2 isolated channels
  • DL350, DL850, DL950, SL1000
  • 701251 Analog Input Module
  • High-Speed 1 Ms/s 16-Bit Isolation Module (2 ch)
  • High sensitivity range (10 mV), low noise (±100 µVtyp), high noise immunity
  • DL850, DL750, SL1000
  • High-Speed 1 MS/s 16-bit Isolation Module (4 ch) 
  • High Noise Immunity  
  • Monitor/test power generator/multi-output power supplies 
  • Dynamic multi-channel data recording analysis
  • DL350 and DL850 series

High-Speed 10 MS/s 12-Bit non-isolation Module (2 ch)
Non-Isolation version of model 720250
Applicable to DL350, DL850 series, DL950 and SL1000.

  • 720268 High Voltage Power Supply Module
  • 300 kHz bandwidth
  • 2 isolated channels
  • Max input (DC+ACpeak) 1000V
  • DC accuracy ±0.25%,
  • DL350, DL850, DL950, SL1000
  • 16 Channel Voltage Input Module
  • Isolated (GND-terminal)
  • Non-Isolated (CH-CH) 
  • Max allowable voltage between sub-channel high inputs 42V (DC + AC Peak)
  • Applicable to DL350 and DL850 series
  • 701261 Universal Module (2 ch)
  • Thermocouple (K, E, J, T, L, U, N, R, S, B, W, iron-doped gold/chromel)
  • Applicable to DL350, DL850 series, DL950 and SL1000.
  • Universal Module (with Anti-Aliasing Filter, 2 ch)
  • Thermocouple (K, E, J, T, L, U, N, R, S, B, W, iron-doped gold/chromel), with AAF
  • DL350, DL850 series, DL950 and SL1000

Temperature/high-precision voltage Module (2 ch)
Thermocouple (K, E, J, T, L, U, N, R, S, B, W, iron-doped gold/chromel), high sensitivity range (1 mV), and low noise (±4 µVtyp)
Applicable to DL350, DL850 series, DL950 and SL1000.

  • The 720266 Temperature Module/Voltage Module
  • 16-Bit, 125 S/s (Voltage) and 125 S/s (Temperature) sample rate
  • DL350, DL850 series, DL950, SL1000
  • 16 Channel Voltage/Temperature Input Module
  • To be used with 701953 Scanner Box
  • Applicable to DL350 and DL850 series
  • Voltage/Temperature Conversion
  • External scanner box for 720221 module
  • Voltage or temperature measurement (scanner method)
  • Thermocouple (K, E, J, T, L, U, N, R, S, B, W, Au-Fe-chromel)
  • Strain Module, NDIS (2 channels)
  • 701955 or 701956 NDIS bridge head
  • Detect/display mechanical stress with ScopeCorder
  • DL350, DL850 series, DL950, SL1000

Strain Module with Shunt Calibration, type DSUB (2 channels) to be used in combination with 701957 or 701958 DSUB bridge head.
Using the strain module and strain gauge the ScopeCorder can detect and display mechanical stress (strain). It works on the principle that the resistance value of a metal foil changes as it expands and contracts.
Applicable to DL350, DL850 series, DL950 and SL1000.

  • 2 channel Voltage Module/Acceleration Module
  • Anti-Aliasing Filter 
  • Direct input from built-in amp type acceleration sensor to measure acceleration 
  • DL350, DL850 series, DL950 and SL1000.
  • 720281 Frequency Module
  • 1 MS/s sample rate 16-bit resolution
  • 2 isolated channels
  • 420 V*2, 42 V*3 max input voltage
  • ±0.1% DC accuracy
  • 0.01 Hz to 500 kHz measurement frequency
  • 720230 Logic Input Module
  • Display input logic signals as waveforms at 10 MS/s sampling resolution
  • Single module can observe 16-bit logic signals 
  • 700986, 700987, 702911, 702912 logic probe
  • DL350, DL850, DL950
  • CAN/CAN FD Monitor Module
  • Decode the CAN/CAN FD-Bus signals, display information on physical data as analog waveforms, compare with sensor data
  • DL850V & DL850EV, DL350 (/VE option), DL950 (/VCE option) ScopeCorder Vehicle Edition
  • 720241 CAN/LIN bus monitor module
  • Decode CAN or LIN-Bus signals
  • Display physical data as analog waveforms
  • DL850V & DL850EV, DL350 (/VE option), DL950 (/VCE option) ScopeCorder Vehicle Edition

Use the SENT monitoring module to decode the SENT protocol signal and display information on physical quantities from SENT output sensors.
Applicable to DL850V & DL850EV, DL350 (/VE option), DL950 (/VCE option) ScopeCorder Vehicle Edition only.

  • CAN FD/LIN Monitor Module
  • Decode the CAN FD/LIN-Bus signals, display information on physical data as analog waveforms, compare with sensor data.
  • DL950 (/VCE option) ,DL350 (/VE option) ScopeCorder Vehicle Edition
  • 1.5m Isolated Probe (ScopeCorder)
  • DC to 200 MHz bandwidth 
  • 100:1 attenuation Isolated
  • BNC connector type 
  • For ScopeCorder Isolated Modules

Passive Probe, 1000V(DC+ACpeak) CAT II, 60MHz, 10:1, 10MΩ, 2.5m
Wide operating temperature range(-40 to 85°C)
For isolated BNC input modules for ScopeCoder series

  • Versatile 700929 passive oscilloscope probe
  • 100MHz frequency bandwidth
  • Isolated input module of ScopeCorder series
  • For use with isolated BNC inputs
  • 701940 Passive Probe
  • 10 MHz, 10:1/1:1, 600 V (DC + ACpeak) CAT II, 1.5 m
  • For ScopeCorder Non-Isolated Modules
  • 701977 Differential Probe for Oscilloscope 7000 V / 50 MHz
  • 50 MHz, 1000:1 / 100:1, Max.
  • Differential Voltage: 5000 Vrms and 7000 Vpeak or less
  • 701978 Differential Probe for Oscilloscope 
  • 1500 V / 150 MHz
  • 500:1 / 50:1
  • Max. Differential Voltage:±1500 V (DC + ACpeak)
  • 701917 oscilloscope current probe
  • Frequency bandwidth: DC to 50 MHz
  • Maximum continuous input range: 5 Arms
  • Functions with Digital Oscilloscopes, ScopeCorders, other waveform measuring instruments
  • Yokogawa 701918 Current Probe
  • Frequency bandwidth: DC to 120 MHz
  • Maximum continuous input range: 5 Arms
  • Functions with Digital Oscilloscopes, ScopeCorders, other waveform measuring instruments
  • 701930 Current Probe 10 MHz / 150 ARMS
  • Powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply
  • 701931 Current Probe 2 MHz / 500 ARMS
  • Powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply
  • 701932 Current Probe 100 MHz / 30 ARMS
  • Powered by Yokogawa Digital Oscilloscopes, Scopecorders, or external power supply
  • 701933 50 by 30 current probe
  • Powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply

The 720930 and 720931 passive clamp-on current probes allow current waveform readings directly via analog input modules on ScopeCorders including the DL350 and DL850 using isolated BNC connections.

  • AC 50 A
  • 40 Hz to 3.5 kHz Bandwidth

The 720931 passive clamp-on current probe anables current waveform readings directly via analog input modules on ScopeCorders including the DL350 and DL850 using isolated BNC connections.

  • AC 200 A
  • 40 Hz to 3.5 kHz Bandwidth
  • 701934 External Probe Power Supply
  • Power supply for current probes, FET probes, and differential probes
  • Supplies power for up to four probes, including large current probes

250 Ω ±0.1%, 0.3 W, ±25 ppm/ ̊C

100 Ω ±0.1%, 0.3 W, ±25 ppm/ ̊C

10 Ω ±0.1%, 0.3 W, ±25 ppm/ ̊C

For DL850/E series, PX8000

Applicable for DL850 and WT300 series.

8-bit, non-isolated, response speed: 1µs, threshold level approx 1.4V
Two measurement leads (B9879PX and B9879KX) included.

  • 700987 Logic Probe - Isolated Inputs
  • 8-bit, isolated, response speed: 1ms or less (DC), 20ms or less (AC), threshold level 6VDC, or 50VAC.
  • 758917 and 758922, 758929, 701954 

8-bit, non-isolated, response speed: 3µs or less, treshold level approx 1.4V
702911: 1 meter cable, 702912: 3 meter cable

Connecting cable for 701953 (3 m)

For the DC power supply model (/DC). Cigarette lighter plug type.

  • 701971 Alligator clip type for DL850EV ScopeCorder
  • For the DC power supply model (/DC).
Rated supply voltage 10 to 30 VDC (at the DL350 connector end).
Maximum power consumption 45 W.
Withstand voltage (when the power is turned off or charging is stopped).
0.6 Wtyp.
DC power cable Cigarette lighter plug Type, length: 2.5 m.

For SL1000, Cable length: 1 m

For SL1000, Cable length: 3 m

Total length: 2 m
USB2.0 Hi-Speed

  • Yokogawa Oscilloscope and ScopeCorder products
  • A1002JC NDIS connector
  • Direct connection to strain module 701270

For DL950,DL350

  • ScopeCorder Accessories for DL850 series, DL750/DL750P, SL1000 & SL1400
  • 701955 NDIS Bridge Head, Bridge resistance: 120Ω , 5m NDIS cable included
  • 701956 NDIS Bridge Head, Bridge resistance: 350Ω , 5m NDIS cable included
  • 701957 and 701958 D-SUB Bridge Head
  • Shunt calibration
  • 5m DSUB cable included
  • Bridge resistance:  120Ω 
  • Bridge resistance:  350Ω 

T-adapter for BNC connectors. Use for circuits having voltage levels no greater than 42 V.

Safety-terminal-binding-post adapter. Use for circuits having voltage levels no greater than 42 V.

For conversion between BNC and female banana plug
Applicable for DL750/DL750P, SL1000 & SL1400.

  • Set of 0.8m long red and black multimeter test leads
  • Used in combination with a pair of optional 758922 or 758929 alligator-clip adapters
  • 1000 Vrms, 32 Arms CAT II

2 pieces (red and black) in 1 set
length: 1.00 m
Used in combination with the 701959, 758921, 758922, or 758929
Rating: 1000 V CAT III/19 A

  • 701901 BNC to Safety Banana 1.8m Cable, 1:1
  • 1000 Vrms-CAT II, 1.8 m long
  • Safety BNC(male) to safety banana(female)
  • 701959, 701954, 758921, 758922, 758929

1:1 Safety Adapter Lead for the 720268 High Voltage Input Module

Set contains one black and one red clip
1000 Vrms-CAT II
2 pieces (red and black) in 1 set 
Connected to the 758933, 758917, or 701901
Length: 0.3m
Applicable for DL750/DL750P, SL1000, SL1400

1000 Vrms CAT III black

1000 Vrms CAT III red

Connected to the 700929, 701947
Maximum input voltage: 1,000V (DC + ACpeak)
Length: 0.26m/0.3m/0.4m
Applicable for DL750/DL750P, SL1000, SL1400

Set contains one black and one red clip.
1000 Vrms-CAT II.

  • Yokogawa 758929 Alligator Clip Adapter 
  • Rated at 1000V
  • Attaches to 758917 test leads
  • Sold in pairs black/red

Rated at 300 V. Attaches to the 758917 test leads. Sold in pairs.

  • 758921 Fork Terminal Adapters
  • For fitting a 4mm banana plug to a fork terminal
  • One black and one red clip
  • 1000 Vrms-CAT II

Two adapters in a set (spring-hold type).

Screw-fastened adapters. Two adapters in a set. 1.5 mm Allen Wrench.

  • 701902/701903 Safety BNC to BNC Cable for oscilloscope
  • Safe, high-voltage measurements with DL350, DL950, and SL1000 isolated input modules 
  • 701902: 1000 Vtms-CAT II (BNC-BNC), 1 m
  • 701903: 1000 Vrms-CAT II (BNC-BNC), 2 m
  • 366924 BNC to BNC cable for oscilloscope 
  • 1m BNC wire
  • Simultaneous measurement with 2 units
  • Input external trigger signal

BNC-BNC 2m. For connection to simultaneously measurement with 2 units, or for input external trigger signal.

  • 1 m long BNC to alligator clip cable
  • Only for circuits with voltage levels no greater than 42 V
  • Applicable for DL750/DL750P, SL1000 & SL1400

A subassembly of 1.2 m long test leads with alligator-clip adapters.
Use only for circuits having voltage levels no greater than 42 V.
Applicable for SL1000 & SL1400.

For 720220 input terminal, one (1) piece

  • 701919 oscilloscope probe stand
  • Flexible arm, heavy base to hold and stabilize 8-13mm probes
  • Can simplify circuit board testing

Quality paper for the DLM2000 /DLM4000 /DL850 /DL6000 /DL9000 and DL750

This is an AC Adaptor for the Portable DL350 ScopeCorder available for use in multiple global regions (North America adaptor pictured).

for DL350, AQ7280 and MT300

Battery pack cover for the 739883 Batery pack.

For DL850/E series

Three pockets are provided for storing accessories and the user’s manual.

Carry your Scopecorder with this carrying case.

Soft Case for Accessories

For SL1000 (EIA)

For SL1000 (JIS)

  • 702915 Current Probe
  • Freq bandwidth: DC to 50 MHz
  • Maxi continuous input range: 0.5 Arms/ 5 Arms/ 30 Arms
  • Digital Oscilloscopes, ScopeCorders, other waveform measuring instruments

Frequency bandwidth: DC to 120 MHz
Maximum continuous input range: 0.5 Arms/5 Arms/30 Arms
Functions with Digital Oscilloscopes, ScopeCorders and other waveform measuring instruments

1000 Vrms CAT III, 1 set each of red and black

How-tos

    Overview:

    Looking for a turnkey high-speed data transfer solution with better bandwidth and minimal manual overhead?

    The 10Gb Ethernet option on the Yokogawa Test&Measurement DL950 ScopeCorder fits that very role and makes capturing and recording high-speed data seamless and convenient.

    Record data at 50 times the speeds of traditional Ethernet and USB connections and automatically transfer data to your PC in a single step using the IS8000 Integrated Software Platform.

    Overview:

    The multi-unit synchronization option for the Yokogawa Test&Measurement DL950 ScopeCorder lets you time synchronize up to five DL950 ScopeCorders, for up to 160 channels of voltage, current, temperature, strain measurements, and more. This video walks you through how to set up and connect the multiple DL950 ScopeCorders, take measurements, and pull the data from all of the instruments for analysis with the IS8000 Integrated Test and Measurement Software Platform.

Looking for more information on our people, technology and solutions?


Contact Us