Voltage Probes

Enhance Measurement Precision with Yokogawa's Advanced Voltage Probes

An oscilloscope's performance heavily relies on the quality of its probes. Yokogawa offers a comprehensive range of voltage probes, including high voltage scope probes, differential probes, active probes, low capacitance probes, and passive types. Our voltage probes cater to a wide range of applications with capabilities up to 7kV and frequency bandwidths reaching 5 GHz.

Key Features of Yokogawa Voltage Probes

Yokogawa's voltage probes are designed to meet the highest standards of precision and reliability:

  • High Voltage Scope Probes: Suitable for measuring high voltage signals with accuracy.
  • Differential Probes: Ideal for measuring between two points in a circuit.
  • Active Probes: Provide high-frequency performance with minimal loading.
  • Low Capacitance Probes: Ensure minimal interference with the circuit being measured.
  • Passive Probes: Robust and versatile for general-purpose measurements.

Applications of Voltage Probes

Yokogawa's voltage probes are used across various industries for diverse applications, including:

  • Oscilloscope Measurements: Ensuring precise and reliable data collection in high-frequency environments.
  • High Voltage Testing: Safe and accurate measurement of high voltage signals.
  • Differential Measurements: Accurate signal measurement between two circuit points.

Advantages of Yokogawa Voltage Probes

Yokogawa's voltage probes offer several benefits, making them the preferred choice for professionals:

  • Wide Range of Options: From high voltage to differential and active probes.
  • High Accuracy and Reliability: Ensure precise measurements every time.
  • Durable and Robust Design: Built to withstand rigorous use in various environments.

Equip your oscilloscopes with Yokogawa's advanced voltage probes to enhance your measurement precision and reliability.

  • 701924 Differential Probe
  • 1 GHz, 50:1, Max. Differential Voltage: ±25 V (DC + ACpeak), Probe Power: dedicated probe interface
  • 701920 Oscilloscope Differential Probe
  • DC to 500 MHz
  • 10:1
  • Max. Input Voltage:(to ground) ±40 V (DC + AC peak)
  • Max. Differential Voltage ±12 V (DC + ACpeak)
  • Probe power supply
  • 50 Ω input system oscilloscope

500 MHz, 50:1, Max. Differential Voltage:±25 V(DC+ACpeak)
Probe Power:Dedicated probe interface

  • 701927 Isolated Differential Probe
  • 150 MHz 
  • Max. Differential Voltage: ±1400 V (DC + ACpeak) at 500:1
  • Probe Power: dedicated probe interface For DLM, DL, and SB5000 series

200 MHz, 10:1, Max. Differential Voltage: ±20 V (DC + ACpeak), Probe Power: probe power supply. Works with 50 Ω input system oscilloscope.

  • 701977 Differential Probe for Oscilloscope 7000 V / 50 MHz
  • 50 MHz, 1000:1 / 100:1, Max.
  • Differential Voltage: 5000 Vrms and 7000 Vpeak or less
  • 701978 Differential Probe for Oscilloscope 
  • 1500 V / 150 MHz
  • 500:1 / 50:1
  • Max. Differential Voltage:±1500 V (DC + ACpeak)

500 MHz, 10:1, 600 V (DC + ACpeak) CAT II, 1.3 m Supplied standard with DLM3000, DLM5000 series

  • 701938 Passive Probe
  • 200 MHz, 10:1, 600 V (DC + ACpeak) CAT II, 1.5 m
  • For DLM2000 (200 MHz model)
  • 701939 Passive Probe 600V / 500 MHz - Current Probe
  • 500 MHz, 10:1, 600 V (DC + ACpeak) CAT II, 1.3 m
  • For DLM2000, DLM4000, DL6000, DLM6000 series
  • 701940 Passive Probe
  • 10 MHz, 10:1/1:1, 600 V (DC + ACpeak) CAT II, 1.5 m
  • For ScopeCorder Non-Isolated Modules

400 MHz, 10:1/1:1, 600 V (DC + ACpeak) or 424 Vrms CAT II, 1.5 m
For DL9000, DL9700/DL9500, SB5000 series

500 MHz, 10:1, 400 Vrms/1250 Vpeak CAT I 300 Vrms CAT II, 1.2 m
For DLM2000, DLM4000, DL6000, DLM6000 series

500 MHz, 10:1, 400 Vrms, 1.3 m
For DLM3000, DLM5000, DLM5000HD series

  • 701944 High Voltage Passive Probe 1000Vrms / 400 MHz
  • For DL1700, DLM2000-6000, DL6000, DL9000, SB5000 series
  • 3m High Voltage Probe (oscilloscope)
  • DC to 250 MHz bandwidth 
  • 100:1 attenuation 
  • Max Input 1000 Vrms CAT II 4000 V transient over-voltage CAT I

200 MHz, 10:1, ±1000 V (DC + ACpeak) CAT II, 2.5 m. Wide operating temperature range (−40 to +85°C).
For DLM2000, DLM4000 series oscilloscopes.

200 MHz, 10:1, ±1000V (DC + ACpeak) CAT II, 2.5 m
Operating environment: −40 to +85°C (no condensation)
For DLM3000, DLM5000, DLM5000HD series.

  • Versatile 700929 passive oscilloscope probe
  • 100MHz frequency bandwidth
  • Isolated input module of ScopeCorder series
  • For use with isolated BNC inputs
  • 1.5m Isolated Probe (ScopeCorder)
  • DC to 200 MHz bandwidth 
  • 100:1 attenuation Isolated
  • BNC connector type 
  • For ScopeCorder Isolated Modules
     

Passive Probe, 1000V(DC+ACpeak) CAT II, 60MHz, 10:1, 10MΩ, 2.5m
Wide operating temperature range(-40 to 85°C)
For isolated BNC input modules for ScopeCoder series

  • 701974 Low Capacitance Probe
  • 5 GHz, 20:1 / 10:1, 20 Vrms / 40 VACpeak, 1.1 m, For DLM series
  • Low input capacitance
  • Low input resistance
  • 700939 Active FET Probe
  • 900 MHz Active FET Probe Circuit
  • 10:1, ±10 V (DC + ACpeak) FET Input Active Probe
  • 1.5 m

 

Overview:

To best utilize SiC devices for improved energy efficiency in equipment, it is important to optimize the internal device peripheral circuits in the inverter according to the device characteristics.

Brochures

Looking for more information on our people, technology and solutions?


Contact Us

Precision Making