Probes

What is a Probe?

A probe is a device that takes and relays measurements.

Types of Probes

  • Differential probes- active analog voltage probe types including switch probes, available for high-speed and high-voltage needs.
  • Logic probes- monitor signals temperature probes, either isolated or non-isolated (compare to multimeter probes).
  • Active probes- analog voltage probe types, including differential and single-ended.
  • Passive probes- analog voltage probe types, available in general-purpose, high voltage, and low capacitance needs.
  • Miniature Passive probes
  • Clamp-on probes
  • 701977 Differential Probe for Oscilloscope 7000 V / 50 MHz
  • 50 MHz, 1000:1 / 100:1, Max.
  • Differential Voltage: 5000 Vrms and 7000 Vpeak or less
  • 701978 Differential Probe for Oscilloscope 
  • 1500 V / 150 MHz
  • 500:1 / 50:1
  • Max. Differential Voltage:±1500 V (DC + ACpeak)
  • 701927 Isolated Differential Probe
  • 150 MHz 
  • Max. Differential Voltage: ±1400 V (DC + ACpeak) at 500:1
  • Probe Power: dedicated probe interface For DLM, DL, and SB5000 series

500 MHz, 50:1, Max. Differential Voltage:±25 V(DC+ACpeak)
Probe Power:Dedicated probe interface

  • 701924 Differential Probe
  • 1 GHz, 50:1, Max. Differential Voltage: ±25 V (DC + ACpeak), Probe Power: dedicated probe interface

200 MHz, 10:1, ±1000 V (DC + ACpeak) CAT II, 2.5 m. Wide operating temperature range (−40 to +85°C).
For DLM2000, DLM4000 series oscilloscopes.

500 MHz, 10:1, 600 V (DC + ACpeak) CAT II, 1.3 m Supplied standard with DLM3000, DLM5000 series

  • 701938 Passive Probe
  • 200 MHz, 10:1, 600 V (DC + ACpeak) CAT II, 1.5 m
  • For DLM2000 (200 MHz model)
  • 701939 Passive Probe 600V / 500 MHz - Current Probe
  • 500 MHz, 10:1, 600 V (DC + ACpeak) CAT II, 1.3 m
  • For DLM2000, DLM4000, DL6000, DLM6000 series
  • 701940 Passive Probe
  • 10 MHz, 10:1/1:1, 600 V (DC + ACpeak) CAT II, 1.5 m
  • For ScopeCorder Non-Isolated Modules

500 MHz, 10:1, 400 Vrms/1250 Vpeak CAT I 300 Vrms CAT II, 1.2 m
For DLM2000, DLM4000, DL6000, DLM6000 series

  • 701944 High Voltage Passive Probe 1000Vrms / 400 MHz
  • For DL1700, DLM2000-6000, DL6000, DL9000, SB5000 series
  • 3m High Voltage Probe (oscilloscope)
  • DC to 250 MHz bandwidth 
  • 100:1 attenuation 
  • Max Input 1000 Vrms CAT II 4000 V transient over-voltage CAT I
  • Versatile 700929 passive oscilloscope probe
  • 100MHz frequency bandwidth
  • Isolated input module of ScopeCorder series
  • For use with isolated BNC inputs

Passive Probe, 1000V(DC+ACpeak) CAT II, 60MHz, 10:1, 10MΩ, 2.5m
Wide operating temperature range(-40 to 85°C)
For isolated BNC input modules for ScopeCoder series

  • 1.5m Isolated Probe (ScopeCorder)
  • DC to 200 MHz bandwidth 
  • 100:1 attenuation Isolated
  • BNC connector type 
  • For ScopeCorder Isolated Modules
     
  • 701974 Low Capacitance Probe
  • 5 GHz, 20:1 / 10:1, 20 Vrms / 40 VACpeak, 1.1 m, For DLM series
  • Low input capacitance
  • Low input resistance
  • 700939 Active FET Probe
  • 900 MHz Active FET Probe Circuit
  • 10:1, ±10 V (DC + ACpeak) FET Input Active Probe
  • 1.5 m

 

400 MHz, 10:1/1:1, 600 V (DC + ACpeak) or 424 Vrms CAT II, 1.5 m
For DL9000, DL9700/DL9500, SB5000 series

1 set 4 pcs Red Black White Blue Ø 4 mm Approx. 3 m

  • 701917 oscilloscope current probe
  • Frequency bandwidth: DC to 50 MHz
  • Maximum continuous input range: 5 Arms
  • Functions with Digital Oscilloscopes, ScopeCorders, other waveform measuring instruments
  • Yokogawa 701918 Current Probe
  • Frequency bandwidth: DC to 120 MHz
  • Maximum continuous input range: 5 Arms
  • Functions with Digital Oscilloscopes, ScopeCorders, other waveform measuring instruments

701928 current probe

Front-end powered

Recognized automatically

Adjust zero position from operation of DLM2000, DLM3000, DLM4000, DL6000/DLM6000, DL9000/DLM9000, SB5000

  • 701929 Current Probe 50 MHz / 30 ARMS
  • Front-end powered
  • Auto-recognized
  • DLM2000-4000, DL/DLM6000, DL/DLM9000, SB5000
  • 701930 Current Probe 10 MHz / 150 ARMS
  • Powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply
  • 701931 Current Probe 2 MHz / 500 ARMS
  • Powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply
  • 701932 Current Probe 100 MHz / 30 ARMS
  • Powered by Yokogawa Digital Oscilloscopes, Scopecorders, or external power supply
  • 701933 50 by 30 current probe
  • Powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply

The 720930 and 720931 passive clamp-on current probes allow current waveform readings directly via analog input modules on ScopeCorders including the DL350 and DL850 using isolated BNC connections.

  • AC 50 A
  • 40 Hz to 3.5 kHz Bandwidth

The 720931 passive clamp-on current probe anables current waveform readings directly via analog input modules on ScopeCorders including the DL350 and DL850 using isolated BNC connections.

  • AC 200 A
  • 40 Hz to 3.5 kHz Bandwidth

Special AC-Input Clamp-on Probes for Large-current Hot Line Measurement

  • 96030 Clamp-on Current Probe
  • AC 200 A: output AC 2.5 mV/A
  • 96031 Current Clamp for Multimeter
  • AC 500 A: output AC 1.0 mV/A
  • 96033 Clamp-on Current Probe
  • AC 50 A: output AC 10 mV/A

φ40 mm AC 2 A, Leakage current measurement.

  • 96061 Clamp-on probe
  • φ18 mm AC 50 A, Load current measurement
  • 96062 Clamp-on Probe
  • Load current measurement
  • φ24 mm AC 100 A

φ30 mm AC 200 A, Load current measurement.

φ40 mm AC 500 A, Load current measurement.

  • 96065 Current clamp-on probe
  • max. approx. 110 mm
  • AC 1000 A flexible type load current measurement
  • 96066 Clamp-on probe
  • max. approx. 150 mm
  • AC 3000 A, 3 CH Load current measurement

AC/DC clamp probe
AC: 130 A (40 Hz to 1 kHz)
DC: ±180 A

701988 (PBL100) Logic Probe

100 kΩ input resistance, toggle frequency of 250 MHz

8-bit, non-isolated, response speed: 3µs or less, treshold level approx 1.4V
702911: 1 meter cable, 702912: 3 meter cable

8-bit, non-isolated, response speed: 1µs, threshold level approx 1.4V
Two measurement leads (B9879PX and B9879KX) included.

  • 700987 Logic Probe - Isolated Inputs
  • 8-bit, isolated, response speed: 1ms or less (DC), 20ms or less (AC), threshold level 6VDC, or 50VAC.
  • 758917 and 758922, 758929, 701954 

90029B -40 to 260°C (Bead TC)

90020B -50 to 600°C (rounded end)
90021B -50 to 600°C (rounded end)
90022B -50 to 600°C (rounded end)
90023B -50 to 500°C (needle)
90024B -50 to 500°C (needle)
90029B -40 to 260°C (Bead TC)

90030B  -20 to 250°C  (Surface straight)
90031B  -20 to 250°C  (Surface angled)
90032B  -20 to 500°C  (Surface straight)
90033B  -20 to 500°C  (Surface angled)

90050B -50 to 600 ° C (For liquids)
90051B -50 to 600 ° C (For liquids)
90055B -20 to 250 ° C (For surfaces)
90056B -20 to 500 ° C (For surfaces)

Length: 1.4 m, MY600 only

Length: 2.0 m, Earth probe and alligator clip adapters

Size: 61.9 × 26 mm

Logic probe accessory kit for use with 701989.

  • 701919 oscilloscope probe stand
  • Flexible arm, heavy base to hold and stabilize 8-13mm probes
  • Can simplify circuit board testing
  • 701934 External Probe Power Supply
  • Power supply for current probes, FET probes, and differential probes
  • Supplies power for up to four probes, including large current probes

200 MHz, 10:1, ±1000V (DC + ACpeak) CAT II, 2.5 m
Operating environment: −40 to +85°C (no condensation)
For DLM3000, DLM5000, DLM5000HD series.

500 MHz, 10:1, 400 Vrms, 1.3 m
For DLM3000, DLM5000, DLM5000HD series

  • 702915 Current Probe
  • Freq bandwidth: DC to 50 MHz
  • Maxi continuous input range: 0.5 Arms/ 5 Arms/ 30 Arms
  • Digital Oscilloscopes, ScopeCorders, other waveform measuring instruments

Frequency bandwidth: DC to 120 MHz
Maximum continuous input range: 0.5 Arms/5 Arms/30 Arms
Functions with Digital Oscilloscopes, ScopeCorders and other waveform measuring instruments

Measure high currents without disassembling existing cabling. Compatible with power analyzers and waveform measurement instruments.

  • Wide-bandwidth high-voltage differential probe
  • 400 MHz bandwidth
  • Max. differential voltage: ±1000V (DC + ACpeak) at 500:1
  • Probe power: Dedicated probe interface for DLM3000, DLM3000HD, DLM5000, DLM5000HD
  • Wide-bandwidth high-voltage differential probe
  • 400 MHz bandwidth 
  • Max. differential voltage: ±2000V (DC + ACpeak) at 1000:1
  • Probe power: Dedicated probe interface for DLM3000, DLM3000HD, DLM5000, DLM5000HD
Overview:

To best utilize SiC devices for improved energy efficiency in equipment, it is important to optimize the internal device peripheral circuits in the inverter according to the device characteristics.

Overview:

In research published by Yale University's Journal of Industrial Ecology (now owned and managed by the International Society of Industrial Ecology), researchers from the University of Nottingham and Dartmouth University use a Yokogawa Test&Measurement CW240 Clamp-On Power Analyzer to measure the real power consumption of the investigated printing systems.