技术与服务热线:400 820 0372

OSA: Characterization of Optical Amplifier Gain and Noise Figure

下载 (398.5 KB)

Applicable model*: AQ6380/AQ6370 series/AQ6360

With the increase in communication traffic, the importance of optical amplifiers such as EDFAs (erbium-doped fiber amplifiers) that can directly amplify optical signals without converting them into electrical signals is increasing in backbone optical transmission networks.

The applicable models are equipped as standard with an optical amplifier analysis function (EDFA-NF) that automatically calculates the gain and noise figure (NF) of the optical amplifier from the input and output optical spectrum of the optical amplifier.

Since the Amplified Spontaneous Emission (ASE) generated by the optical amplifier is superimposed on the output light of the optical amplifier, it is important to measure this noise component separately in optical amplifier evaluation. The optical amplifier analysis function identifies the ASE component by the curve fitting and interpolation method. In addition, the curve fitting method and analysis conditions can be set according to the actual spectrum, so the gain and NF can be obtained accurately.

* All versions unless otherwise specified. 

  AQ6373 family are not applicable.

Optical amplifier analysis function (EDFA-NF)

nCalculate the gain and NF for each channel of the input optical signal.
(Compatible with DWDM signals.)
nAnalysis results such as wavelength, gain, and NF are displayed in a list or graph for each channel.
nPossible to set analysis parameters such as channel detection and ASE level detection

OSA: Characterization of Optical Amplifier Gain and Noise Figure

相关产品和解决方案

AQ6370E Telecom 600 - 1700 nm

  • 0.02 nm resolution
  • ±8 pm accuracy
  • 78 dB close-in dynamic range
  • -90 dBm level sensitivity
  • Single-mode and multi-mode
  •  

AQ6375E 长波长光谱分析仪 1200~2400nm和 1000~ 2500 nm

  • 0.05 nm 分辨率
  • ±50 pm 精度
  • 55 dB 动态范围
  • -70 dBm 功率灵敏度
  • 单模和多模
  • 近红外和短波红外波长

光通信产业专用高速光谱分析仪 AQ6361 1200-1700 nm

  • 0.03 nm 波长分辨率
  • ±20 pm 波长精度
  • 55 dB 动态范围
  • -80 dBm 功率灵敏度
  • 减少生产测试时间

可见光波长光谱分析仪 AQ6373E 350 - 1200 nm

  • 0.02 nm 分辨率
  • ±50 pm 精度
  • 60 dB 动态范围
  • -80 dBm 功率灵敏度
  • 单模和多模
  • 工业和生物医学激光测试

多应用测量系统

光学器件测量的最佳测试系统

宽范围波长光谱分析仪 AQ6374E 350 - 1750 nm

  • 0.05 nm 分辨率
  • ±50 pm 精度
  • 60 dB 动态范围
  • -80 dBm 功率灵敏度
  • 单模和多模
  • 从可见光到通信波长