YOKOGAWA的新型DLM6000系列数字混合信号示波器,广泛的市场调查和用户反馈为基础,让外形和屏幕界面焕然一新。该仪器为最常用的设置配备专用的背光按钮,而且采用了Yokogawa独有的控制器,例如5向选择按钮和弹簧加压“飞梭旋钮”控制。 DLM6000系列示波器提供丰富的波形特征分析功能,是用于检测毛刺和异常现象的强大工具。先进的信号增强和降噪技术,以及各种串行总线分析和功率测量选件。四个通道和16或32位逻辑输入,有500MHz、1.0GHz和1.5GHz带宽机型可供选择。 订单终止日:2012年4月2日;正式停产日:2012年9月底(特注订单)。
此探头不需要额外的电源连接(LEMO接口),可被自动识别,通过DLM2000、DLM3000、DLM4000、DL6000/DLM6000、DL9000/DLM9000、SB5000系列的操作调整零位。
用于DC电源型号(/DC)。鳄鱼夹型。
高品质的打印纸,用于DLM6000/DL9700/DL9500/DL1700(E)/DL1600(E)/DL1500和DL7400系列。
用于DLM2000/DLM4000/DL850/DL6000/DL750的优质纸张
测量精确的上升时间已经变得越来越简单,然而,不仅示波器贡献的误差很容易被忽略,探头也是如此。而且,虽然示波器的有限阶跃响应(上升时间)产生的误差通常计算在内,探头产生的误差也经常被忽略。
Frequency to Voltage Conversion Problem: A transducer produces a sine-wave output dependant on the voltage-input; here is how to decode that output with a scope or a ScopeCorder. For 3kV input, the transducer ...
Question:If the DL9000 Oscilloscopes is in normal trigger mode and no waveform acquisitions have been made i.e. the scope has not triggered, a query to the instrument using the :Waveform:Record or :History:Record? Minimum it returns ...
The Time Axis Accuracy is the accuracy of the A/D clock. It is not possible to directly measure the A/D clock and the A/D clock is not output from the ScopeCorder DL850/SL1400. To verify the accuracy of the A/D clock, you will ...
Even though the display record length is shorter than the specified record length, measurement is made over the full record length. There is no function that allows you to move the display position to view the other ...
The measured propagation delay for the PB500 500 MHz Passive Probe (701943) is approximately 8.2 ns. A simple way of measuring the propagation delay, using the DL9000, is to measure the delay between two ...
High Resolution mode can be used to remove high frequency noise and increase vertical resolution. It achieves this by increasing the number of effective bits per data to 12-bits through digital and bandwidth filters.
Decimation is a technique used to reduce the total number of samples. You can use Xviewer to perform decimation on your waveform data files that have the WDF/WVF/ASCII CSV extension format. Decimation reduces the ...
If your DL series oscilloscope is not measuring rise or fall time, it may be because you are attempting to measure asymmetric waveforms. It is not possible to perform automatic rise or fall time measurements on DL ...
There are two methods to programmatically determine if the calculations for waveform parameters is completed on the DL series oscilloscopes. Send the :MEAS:WAIT? command. This will ensure that no other commands are ...
The DLM2000 Series mixed signal oscilloscopes are capable of performing enhanced parameter measurements and calculations. This feature allows you to perform automated measurements of waveform parameters of two different areas. It ...
The DL series instruments are capable of measuring the delay between traces or the delay between channels. The measured output value can be displayed in either time or degree. To setup the DL850 Scopecorder to measure delay, follow ...
The AC Power Input in all Yokogawa instruments is designed as a 3-pin connection (one of which is a GND pin). In some parts of the world, PCs are sold with AC power cables that are 2-pin. Often times this means the ...
The free software DL-GATE can be used for the following products only:DL1700E seriesDL7400 series (firmware version after 1.32)DL1600 series (firmware version after 1.13)DL750 series (firmware version after ...
The sanitation procedure for various Yokogawa oscilloscopes have been documented below. Please download the document or pdf that refers to your Yokogawa oscilloscope.
The Header Size entry, for a ASCII format data file, denotes the number of header lines in the header part of the ASCII File.
The DLM6000 Mixed Signal Oscilloscope shows the network icon to notify the user that the instrument is disconnected from a network. This is a specification of the LXI standard that is on the DLM6000 that requires the instrument to show the icon ...
You can express any arbitrary exponentiation, in Xviewer or DL series instruments, by using the LOG (common logarithm) and EXP (exponential) functions. For example, for C1 raised to the exponent of 0.2, the math ...
The true noise floor of a Yokogawa oscilloscope is ≤ 2-3mVpp. The DL9000 Digital Oscilloscope, for example, has approximately 280uV residual noise at 2mV/Div with input termination set to 50Ω. The residual noise may be measured by ...
In general, the recommended sampling rate for CAN bus or I2C analysis is 10x the bit-rate. If the waveform is not noisy, the sampling rate can be set to around 4-5x the bit-rate.
The IEC Harmonic analysis on the DL/DLM series oscilloscopes provides a rough analysis and estimation for harmonic testing. The scope will perform an FFT on the current waveform and can be used to measure the general ...
Yes, VXI-11 is required and needs to be enabled for the DLM2000 Mixed Signal Oscilloscope to connect properly to Xviewer when using an ethernet connection. If the VXI-11 option is unchecked, a connection failed message will appear. Related ...
If you selected Decimation or P-P Compression when saving waveform data in ASCII CSV format, then the HResolution will not be equivalent to the Sampling Rate. If Decimation or P-P Compression is not selected, then ...