  • Signal source: DCV (Max. 30V), DCA (Max. 24 mA)
  • Measurement: DCV (Max. 30V), DCA (Max. 100 mA)
  • Features: Auto step (4 to 20mA), 20mA SINK, Sweep function

Specifications - Model CA11E-1

Features Source and Measuring of Voltage and Current: Generates and measures voltages up to 30 V DC and currents up to 24 mA DC.
Improved display resolution for current: The generation/measurement resolution has improved to 0.001 mA.
24 V (20 mA)/Loop check function: Enables measurement of generated current signals while supplying loop power to two-wire transmitter. Load current: Max. DC22 A
20 mA SINK Function: Absorbs the voltage supplied from an external power supply to its H terminal and simulates a two-wire transmitter making it ideal for loop checks.
4-20 mA and 1-5 V DC Step-up/down Function: The output level can be changed between 4-8-12-16-20 mA signals by one touch for the 4-20 mA DC output, and between 1-2-3-4-5V signals for the 1-5 V DC output, for efficient calibration work.
Sweep Function: Increases and decreases the output level to the preset level at a constant rate for the selected sweep time (16 or 32 seconds). The sweep function and sweep time are set by the internal dip switches.
Standard Accessories Carrying Case
Power Supply Four 1.5-V alkaline batteries (ANSI AA-size) or dedicated AC adapter (sold separately)
Battery Life Approx. 25 hours for 20 mA DC output (with a load of 5 V)
When generating a signal continuously on alkaline batteries
Approx. 50 hours for 5 V DC output (with a load of 10k? or greater) When generating a signal continuously on alkaline batteries
Automatic Power-Off Approx. 10 minutes (Can be canceled by DIP switch setting)
Generation Signal Level Setting By four-digit up/down keys
Response of Generator Approx. 1 second (from when the output begins to change until when the output level falls within the specified accuracy)
Maximum Allowable 30 VDC or less between each terminal and ground
Measurement Display Approx. 1 update/sec.
Update interval Display 7 segments LCD
Operating Temperature/Humidity Range 0 to 50°C and 20 to 85%RH (no condensation)
Storage Temperature/Humidity Range -20 to 50°C and 90%RH or less (no condensation)
Dimensions Approx. 192 (W) x 92 (H) x 42 x (D) mm (Excluding protrusions)
Width 192 mm
Height 92 mm
Thickness 42 mm
Weight Approx. 440 g (including batteries)
Additional Features Complete Protection (CA11E)
Dip Switches (inside battery compartment)
Longer Lead Cables
Rubber Boot
Runs on 1.5 V AA-size Batteries or AC Adapter
Simple and Easy Calibration

 

Additional Features

  • Automatic Power-off
    Power is turned off automatically if the calibrator is not touched for 10 minutes, prolonging battery life.
  • Runs on 1.5 V AA-size Batteries or AC Adapter
    The handy calibrators can run on the built-in 1.5-V ANSI batteries or an AC power supply using the AC adapter (sold separately).
  • Longer Lead Cables
    The slightly longer than usual lead cables of 1.7 m (approximately 0.1 Ω for both cables) allow easy cable connection even if the handy calibrator is put on the floor.
  • Compact and Lightweight
    Almost the same size and weight as a hand-held digital multimeter, this calibrator is designed for use in the field.
  • Simple and Easy Calibration
    For the CA11E and CA12E, There is performing calibrations during periodic maintenance as they can be simply calibrated by the up/down keys.
  • Complete Protection (CA11E)
    The complete protector protects the circuit against short-circuiting of the voltage output terminals and application of a voltage (of up to 30 V) to the output terminals, etc. due to misconnection.
  • Dip Switches
    (inside battery compartment)
  CA11ECA12E
Switch Number ON OFF ON OFF
1 Sweep function Sweep function -off The built-in RJC is on. External RJC is on
2 32 s 16 s °F °C
3 24 24 PT100-IPTS68 PT100-ITS90
4 Automatic power-off is disabled. Automatic power-off Automatic power-off is disabled. Automatic power-off

 

ModelDescription
CA11E-2Voltage/Current Calibrator with rubber boot, strap and accessory case Signal source: DCV (Max. 30V), DCA (Max. 24 mA) Measurement: DCV (Max. 30V), DCA (Max. 100 mA) Features: Auto step (4 to 20mA), 20mA SINK, Sweep function Standard Accesories: Rubber boo
CA11E-1Voltage/Current Calibrator with carrying case Signal source: DCV (Max. 30V), DCA (Max. 24 mA) Measurement: DCV (Max. 30V), DCA (Max. 100 mA) Features: Auto step (4 to 20mA), 20mA SINK, Sweep function Standard Accesories: Carrying Case

Looking for more information on our people, technology and solutions?


Contact Us

Precision Making

Top