Motor Surge Measurement with High Definition Oscilloscope

Download (229 KB)

Motor Surge Measurement with High Definition Oscilloscope

Issue:

The high-speed switching voltage of the inverter generates a high-voltage surge on the motor side, which can cause dielectric breakdown of the windings. Therefore, checking the motor surge voltage is an essential process in motor development and manufacturing. In recent years, as the efficiency of inverters using high-speed devices such as SiC has improved, the voltage and speed of motor surges have increased and the phenomenon has become more complex, requiring more accurate waveform analysis.

Solution:

The DLM5000HD equipped with a 12-bit ADC can simultaneously capture 8 channels of surges and related waveforms with high resolution, enabling more reliable and efficient surge voltage analysis.

Example: Observation of motor surge of SiC MOSFET_1

Example: Observation of motor surge of SiC MOSFET_2

Example: Observation of motor surge of SiC MOSFET

Related Industries

Related Products & Solutions

701927 Differential Probe 1400V / 150 MHz

  • 701927 Isolated Differential Probe
  • 150 MHz 
  • Max. Differential Voltage: ±1400 V (DC + ACpeak) at 500:1
  • Probe Power: dedicated probe interface For DLM, DL, and SB5000 series

701978 Differential Probe 1500 V / 150 MHz

  • 701978 Differential Probe for Oscilloscope 
  • 1500 V / 150 MHz
  • 500:1 / 50:1
  • Max. Differential Voltageļ¼š±1500 V (DC + ACpeak)

702921 PBDH0400 Differential Probe 1000 V / 400 MHz

  • Wide-bandwidth high-voltage differential probe
  • 400 MHz bandwidth
  • Max. differential voltage: ±1000V (DC + ACpeak) at 500:1
  • Probe power: Dedicated probe interface for DLM3000, DLM3000HD, DLM5000, DLM5000HD

702922 PBDH0400 Differential Probe 2000 V / 400 MHz

  • Wide-bandwidth high-voltage differential probe
  • 400 MHz bandwidth 
  • Max. differential voltage: ±2000V (DC + ACpeak) at 1000:1
  • Probe power: Dedicated probe interface for DLM3000, DLM3000HD, DLM5000, DLM5000HD