Voltage Calibrator - Current Calibrator
Features | Source and Measuring of Voltage and Current: Generates and measures voltages up to 30 V DC and currents up to 24 mA DC. Improved display resolution for current: The generation/measurement resolution has improved to 0.001 mA. 24 V (20 mA)/Loop check function: Enables measurement of generated current signals while supplying loop power to two-wire transmitter. Load current: Max. DC22 A 20 mA SINK Function: Absorbs the voltage supplied from an external power supply to its H terminal and simulates a two-wire transmitter making it ideal for loop checks. 4-20 mA and 1-5 V DC Step-up/down Function: The output level can be changed between 4-8-12-16-20 mA signals by one touch for the 4-20 mA DC output, and between 1-2-3-4-5V signals for the 1-5 V DC output, for efficient calibration work. Sweep Function: Increases and decreases the output level to the preset level at a constant rate for the selected sweep time (16 or 32 seconds). The sweep function and sweep time are set by the internal dip switches. |
---|---|
Standard Accessories | Carrying Case |
Power Supply | Four 1.5-V alkaline batteries (ANSI AA-size) or dedicated AC adapter (sold separately) |
Battery Life | Approx. 25 hours for 20 mA DC output (with a load of 5 V) When generating a signal continuously on alkaline batteries Approx. 50 hours for 5 V DC output (with a load of 10k? or greater) When generating a signal continuously on alkaline batteries |
Automatic Power-Off | Approx. 10 minutes (Can be canceled by DIP switch setting) |
Generation Signal Level Setting | By four-digit up/down keys |
Response of Generator | Approx. 1 second (from when the output begins to change until when the output level falls within the specified accuracy) |
Maximum Allowable | 30 VDC or less between each terminal and ground |
Measurement Display | Approx. 1 update/sec. |
Update interval Display | 7 segments LCD |
Operating Temperature/Humidity Range | 0 to 50°C and 20 to 85%RH (no condensation) |
Storage Temperature/Humidity Range | -20 to 50°C and 90%RH or less (no condensation) |
Dimensions | Approx. 192 (W) x 92 (H) x 42 x (D) mm (Excluding protrusions) |
Width | 192 mm |
Height | 92 mm |
Thickness | 42 mm |
Weight | Approx. 440 g (including batteries) |
Additional Features | Complete Protection (CA11E) Dip Switches (inside battery compartment) Longer Lead Cables Rubber Boot Runs on 1.5 V AA-size Batteries or AC Adapter Simple and Easy Calibration |
CA11E | CA12E | |||
---|---|---|---|---|
Switch Number | ON | OFF | ON | OFF |
1 | Sweep function | Sweep function -off | The built-in RJC is on. | External RJC is on |
2 | 32 s | 16 s | °F | °C |
3 | 24 | 24 | PT100-IPTS68 | PT100-ITS90 |
4 | Automatic power-off is disabled. | Automatic power-off | Automatic power-off is disabled. | Automatic power-off |
Model | Description |
---|---|
CA11E-2 | Voltage/Current Calibrator with rubber boot, strap and accessory case Signal source: DCV (Max. 30V), DCA (Max. 24 mA) Measurement: DCV (Max. 30V), DCA (Max. 100 mA) Features: Auto step (4 to 20mA), 20mA SINK, Sweep function Standard Accesories: Rubber boo |
CA11E-1 | Voltage/Current Calibrator with carrying case Signal source: DCV (Max. 30V), DCA (Max. 24 mA) Measurement: DCV (Max. 30V), DCA (Max. 100 mA) Features: Auto step (4 to 20mA), 20mA SINK, Sweep function Standard Accesories: Carrying Case |