An Optical Spectrum Analyzer (or OSA) is a precision instrument designed to measure and display the distribution of power of an optical source over a specified wavelength span. An optical analyzer spectrum trace displays power in the vertical scale and the wavelength in the horizontal scale.
The expanding field of optics-related applications has created a variety of industries and organizations that require advanced optical spectral measurements for both R&D and manufacturing. These industries include telecommunications, consumer electronics, healthcare, life science/medical research, security, sensing, microscopy, and gas/chemical analysis, and environmental monitoring.
Yokogawa (formerly Ando) is the global leader in optical spectrum analyzers, delivering high quality, cutting-edge technology with dependability, performance, and flexibility for over thirty years.
AQ6380 OSA: 5 pm high wavelength resolution, ±5 pm accuracy, 65 dB wide close-in dynamic range, 80 dB high stray light suppression
High Performance LONG WAVELENGTH
The AQ6375E covers not only telecommunication wavelengths, but also the SWIR region which is often used for environmental sensing and medical applications.
・Lineup of 3 models [Standard, Extended and Limited]
・Covers wavelengths
1200 to 2400 nm [Standard, and Limited]
1000 to 2500 nm [Extended ]
MWIR WAVELENGTH with internal gas purge and cut filter
The AQ6376E is the latest version of our bench-top optical spectrum analyzer extending the wavelength coverage well beyond the NIR range of our previous models into the MWIR region from 1500 to 3400 nm.
Popular applications include the detection of gases such as carbon oxides (COx), nitrogen oxides (NOx), and hydrocarbon gas (CxHy) for environmental studies.
The AQ6370 Viewer is a package of PC application software for the AQ6380, the AQ6360, and the AQ6370 series Optical Spectrum Analyzer.
Band |
Optical Communications |
VIS |
VIS & Optical |
exNIR |
MWIR |
MWIR |
Optical Communications |
||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Model Number |
|||||||||||||||
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
|||||||||
Wavelength Range |
600 - 1700 nm |
350 - 1200 nm |
350 - 1750 nm |
1200 nm - 2400 nm |
1500 nm - 3400 nm |
1900 nm - 5500 nm |
1200 nm - 1650 nm |
||||||||
Applications |
General Purpose, Telecommunications |
Bio-Photonics |
General Purpose, Telecommunications Bio-Photonics |
Environmental Monitoring Gas Sensing |
Environmental Monitoring Gas Sensing |
Environmental Monitoring Gas Sensing |
Optics Research Telecommunications |
||||||||
Applicable Fiber |
SM, GI50, GI62.5 |
SM, GI50, GI62.5 |
SM, GI50, GI62.5 |
SM, GI50, GI62.5 |
SM, GI50, GI62.5 |
SM, Large Core up to 400um |
SM (9.5/125 um) |
||||||||
Wavelength resolution setting (nm) |
Min. |
0.02 |
0.01 |
0.05 |
0.05 |
0.1 |
0.2 |
0.005 |
|||||||
Max. |
2 |
10 |
10 |
2 |
2 |
5 |
2 |
||||||||
Wavelength accuracy (nm) |
±0.1 (Full range) ±0.04 (1450 to 1520 nm) |
±0.2 (Full range) +/-0.05 nm (633 nm) |
±0.2 (Full range) ±0.05 (633 nm) ±0.05 (1523 nm) |
±0.5 (Full range) ±0.05 (1520 to 1580 nm) ±0.1 (1580 to 1620 nm) |
±0.5 (Full range) |
±0.5 (Full range) |
±0.5 (Full range) |
||||||||
+/-0.02 nm |
+/-0.01 nm |
||||||||||||||
Maximum Sensitivity |
-90 dBm |
-80 dBm |
-80 dBm |
-70 dBm |
-65 dBm |
-60 dBm |
-85 dBm |
Lack of reliable high-speed internet access in rural regions, due to complicated logistics and the considerable costs involved to extend land-based networks to these areas, has inspired a wave of next-generation applications that will provide greater accessibility and reliability. Making use of “space laser” networks, these revolutionary solutions can relay digital traffic via low Earth orbit (LEO) satellite systems to provide low-latency, high-speed broadband services to communities typically beyond the reach of standard wireless and fiber networks.
To accurately measure pulsed light using an optical spectrum analyzer (OSA), it is necessary to understand the characteristics of the OSA and select the appropriate measurement method and settings.
We have developed the AQ6375 Optical Spectrum Analyzer grating-based desktop optical spectrum analyzer, which can measure an optical spectrum over a wide wavelength range from 1.2 to 2.4 m with high wavelength resolution at high speed. Despite the popularity of desktop optical spectrum analyzers in the telecommunication wavelength region, a large-scale optical spectrum measurement system with a monochromator has commonly been used for measuring the long wavelength region, and so there was a need for a desktop optical spectrum analyzer for long wavelengths. Deep optical absorptions appearing in the long wavelength region around 2 m caused by CO2, NOX and H2O are attracting attention in the environmental and medical fields, and thus sensitive measuring equipment by laser absorption spectroscopy using a near infrared semiconductor laser is becoming more popular. With excellent optical spectrum measurement capabilities (high resolution and high speed), operability and maintenance performance, the AQ6375 Optical Spectrum Analyzer optical spectrum analyzer will contribute to the performance improvement and spread of near-infrared semiconductor lasers used in laser absorption spectroscopy.
A new type of computer based on the theory of quantum mechanics, a quantum computer, is currently in development by researchers around the globe. The theory of quantum mechanics describes nature at the atomic and subatomic level. Quantum technology has the potential to build powerful tools that process information using the properties of atoms, photons, and electrons. These quantum computers could also address challenges of much greater complexity than what today's computers can solve, and help further advancements in science, technology, medicine, and more.
With countries spending billions of dollars, the race for who can produce the first practical, commercialized quantum computer is on. There are currently several approaches to build this sort of computer, and this all begins with creating and initializing quantum bits, also known as qubits.
This paper describes a compact optical channel monitor and a delayed interferometer having free-space optical elements such as lenses or mirrors, as an application of microoptics. These devices have been developed to be built into dense wavelength division multiplexing (DWDM) transmission systems. These optics use a Gaussian beam which is emitted through single-mode optical fibers and located near the optical axis. This paper explains the optical designs of these devices based on the Gaussian beam's behavior.
SANPEI Yoshihiro*1 SUZUKI Yasuyuki*2 IEMURA Kouki*3 ASANO Junichirou*3
*1Communication and Measurement Business Headquarters, Optical Communication Measurement Development Department
*2Communication and Measurement Business Headquarters, Core Technology Development Department
*3Photonics Business Headquarters, Engineering Department IV
Wavelength accuracy: Wavelength accuracy is a tolerance to the true value of a measured value when the standard wavelength is measured. Wavelength repeatability:Wavelength repeatability is the stability of ...
If you are performing wavelength calibration using the instrument's built-in light source, the warning message is an indication that the monochromator needs to be repaired. Please visit our Contact site to locate ...
Please download the attached application note for instructions on how to make High Bit Rate Modulated OSNR Measurement for the AQ6319 and AQ6370 series Optical Spectrum Analyzer..
The Chopped Light mode is used: To increase measurement level sensitivity by cutting the high frequency noise To detect only the light that the LS emitted, effective for free space measurement. In free space ...
If you have products currently in China that require calibration or repair, you may either return them to your local Yokogawa service center or the Yokogawa China Service & Repair Center. Please be advised that ...
The AQ6373 optical spectrum analyzer performs the color analysis function as follows:1. Measure the spectrum 2. Compare the measured spectrum with “color matching functions” as defined by the CIE Using these ...
Level Accuracy:Level Accuracy is a tolerance to the true value of measured value, when a standard level is measured with a standard wavelength. Level Linearity:Level Linearity is the width of error dispersion ...
The remote viewer may not start if the screen resolution is too low. Adjust the screen resolution to 1024 by 768 pixels (or larger) then restart the software.
Yes, the AQ6370 Optical Spectrum Analyzer Viewer Software is compatible with Windows 7 32-bit and 64-bit. Note: Please make sure the correct USB driver is installed for either Windows 7 32-bit or 64-bit.
If the AQ637X series Optical Spectrum Analyzer is already running and you attempt to connect an external display, the OSA will not automatically detect the external display. The OSA will need to be re-booted before it can recognize and ...
Please clean the fiber used between the calibration output and the optical input.
The AQ6370 OSA cannot load and re-display the data saved by an AQ6370B. However, the AQ6370 Viewer software can display the data saved by both instruments. Also please note that the AQ6370B OSA can load and re-display ...
The maximum input power that the AQ6370B Optical Spectrum Analyzer can measure for pulsed light measurements is +20dBm per resolution at full span, per channel. Keep in mind that this limit is applicable to an averaged power of pulsed light, ...
The resolution is controlled by 3 factors: Input Slit Detraction Grating Output Slit The resolution setting controls the output slit disk. This disk has a fixed number of slits in it. Since the setting only control ...
For the AQ6373 Optical Spectrum Analyzer you can use a maximum 800 micron core fiber that must be terminated in a standard FC connector. For the AQ6375 and AQ6370 series OSA you can use a maximum 200 micron core fiber which, ...
The AQ637X Optical Spectrum Analyzer has a feature called Auto Offset that it performs every 10 minutes. What this feature does is zero out the OP amps in the OSA to ensure constant level accuracy. This feature will however, stop the OSA ...
No, unfortunately due to the number of current fiber combinations, we do not stock optical fibers. There are many companies that specialize in optical fiber cords.
The AQ6370C Optical Spectrum Analyzer was developed in accordance with the IEC standard: WG4 (IEC 61280-1-3) Test procedures for general communication subsystems -Central wavelength and spectral width measurement. We cannot guarantee the RMS ...
How to get the resolution bandwidth of an older, saved trace on an OSA (optical spectrum analyzer)
:MEMory:LOAD command
SENSE:BANDWIDTH:RESOLUTION?
This comprehensive training module covers the following topics:
The extreme test requirements of our research called for an OSA with extended MIR spectrum bandwidth capabilities up to 5μm, but we couldn’t find one on the market capable of measuring optical inputs at these wavelengths. Yokogawa Test&Measurement rose to the challenge and developed a new OSA model for us that would. Not only do we now have an instrument that is practically custom-made for our needs, it provides repeatable, accurate, and trusted measurement outputs and is easy to learn and use. Their equipment and ability to create a new optical measurement solution has definitely increased the overall efficiency and productivity of our research team.
— Martin Bernier, PhD, P.Eng., Full Professor, Centre de Optique, Photonique, et Laser, Université Laval
In this poster session research from The European Conference on Lasers and Electro-Optics 2017, researchers from Texas A&M University, Texas A&M University at Qatar, and Florida A&M University use a Yokogawa Test&Measurement AQ6376 Optical Spectrum Analyzer to detect methane in the air.
In a research paper published on Nature.com, a team of researchers from the University of Virginia, Peking University, Shanxi University, and California Institute of Technology use a Yokogawa Test&Measurement Optical Spectrum Analyzer in order to achieve spectrum measurements above 1200 nm.
The AQ6370 Optical Spectrum Analyzer is Yokogawa's high speed and high performance Optical Spectrum Analyzer for characterization of optical communications system and optical components. Thirteen built-in analysis functions and seven trace calculations for popular applications can be utilized with a simple function key. Yokogawa continues to provide you quality products that simplify your business practices.
From visible light to telecommunication bands and even up to applications in the 2000nm region, optical testing professionals count on the Yokogawa Test&Measurement optical testing family of products. For decades, these precision-based optical measuring instruments have met and exceeded the needs of many customers’ experimental requirements. Applicable to a range of uses in R&D, manufacturing, and academia, Yokogawa Test&Measurement OSAs, OTDRs, OWMs, modular manufacturing test systems, and more deliver quality, consistency, ease of use, and market leadership for all manner of optical test applications.
Introducing the new Yokogawa Test&Measurement AQ6380 Optical Spectrum Analyzer. This new OSA includes many sought-after features including:
• An unprecedented 5 pm wavelength resolution
• ±5 pm wavelength accuracy
• 1200 nm to 1650 nm wavelength range
• 65 dB wide close-in dynamic range
• 80 dB stray light suppression
• Automated wavelength calibration
• Gas purging
• DUT-oriented interface and test apps
• Backward-compatible remote interface
• 10.4in intuitive touchscreen
• Up to 20x faster measurement
• Remote operation capabilities
The AQ6375 is the first bench-top optical spectrum analyzer covering the long wavelengths over 2 ?m.
It is designed for researchers and engineers who have been struggling with inadequate test equipment to measure in these long wavelength ranges. The AQ6375 achieves high speed measurements with high accuracy, resolution and sensitivity, even while providing full analysis features. Troublesome calibration steps and the development of external analysis software is no longer required.
A vision of self-driving cars propels the research and development of automotive LiDAR, a vital hardware providing distance and velocity information of a vehicle’s surroundings. Some LiDAR concepts are already heading toward production for automotive ADAS and industrial markets. Two newer concepts promise the greatest potential yet: frequency-modulated continuous wave (FMCW) LiDAR and time-of-flight (TOF) flash LiDAR. However, there are engineering challenges impeding their full adoption. This webinar reviews operation principles and challenges of different LiDAR concepts, a brief discussion on the LiDAR market, and a review of critical optical components such as photodetectors and sources.
Key takeaways include:
Increasing demands for greater network bandwidth and expansion of 5G wireless backhaul has driven data rates to 400G, 800G, and beyond. Starting with the physical layer of the optical network stack, precision measurement of these light speed signals is crucial.
This webinar covers a range of alternatives used to evaluate test parameters for DWDM, OSNR, SMSR, and EDFA, and includes a discussion on interesting applications like the use of high-energy lasers across space satellite mesh networks.
Key topics include:
In this webinar, Michael Kwok will discuss general techniques to measure OSNR for both traditional and modulated optical signals. The goal of the webcast is to provide test engineers with key measurement considerations for performing OSNR measurements using an Optical Spectrum Analyzer or OSA.
Yokogawa launches new Optical Spectrum Analyzers covering short and mid wavelength infrared range
Yokogawa Test&Measurement, a pioneer and leader in precision optical measurement, is pleased to announce that the latest addition to its optical spectrum analyzer line, the AQ6380 Highest Performance OSA has received the highest score, 4.5/5.0, in the Lab/Production Test Equipment class by 2022 Lightwave Innovation Reviews.
High Performance LONG WAVELENGTH The AQ6375 is the first bench-top optical spectrum analyzer covering the long wavelength over 2 μm.It is designed for researchers and engineers who have been struggling with inadequate test equipment to measure in ...
- Industry-leading performance in dispersive spectroscopy achieves 5 pm wavelength resolution -