DL9000 DSO Series (DISCONTINUED)

Notice: This product was discontinued on Jun 30, 2012.

Winner of Test & Measurement World's "Best in Test" award, the DL9000 offers you the strongest combination of performance, ease of use, and value among digital oscilloscopes in the 500 MHz to 1.5 GHz range. It contains a wide array of analysis functions that include parameter statistics, trends, real time filters, serial bus analysis and power analysis.
DL9000 models are available with 2.5 M points of waveform memory on each of four channels and with an "L" version containing 6.25 M points on each channel. In accumulate mode, the DL9000 overlays up to 2000 acquisitions on the screen that you can scroll through to look for signal peculiarities.

Affordable Performance for 500 MHz/1 GHz /1.5 GHz BW Measurements

The standard DL9000 series is equipped with 2.5 M word/ch record length, dot density display technology and a wide variety of analysis and trigger functions. For full 1 GHz/1.5 GHz BW measurements, optional 2.5 GHz active probes are available. These make the DL9000 series the most affordable 500 MHz/1 GHz/1.5 GHz measurement system available today.

 

Tm Dl9000 02

                                         Advanced display technology                                Mask testing

(dot density display)                                                             

DL9000 Trigger types
DL9000 Trigger Types

History Memory with Fast Signal Acquisition

Fast signal acquisition helps you avoid missing anomalies. However, simple superimposed waveform displays only tell whether or not an anomaly occurred. Such displays do not provide information about when the anomaly occurred, what events occurred before the anomaly, nor what happened after the anomaly. The DL9000's History memory function allows you to view and analyze up to 2000 previously acquired waveforms, even after the acquisition stops. This offers unparalleled insight into waveform behavior and makes troubleshooting easier.

History memory advantage #1: Correlate events from multiple channels

Ex 1: Display shows superimposed history waveforms
Ex 1: Display shows superimposed history waveforms
  (Up to 2000 waveforms can be saved in history memory)


History memory advantage #2: Determine sequence of events

History memory captures and saves waveforms before and after the anomaly; thus providing insight into the cause and effect of the anomaly.
History memory captures and saves waveforms before and after the anomaly; thus providing insight into the cause and effect of the anomaly.
 


Security for Confidential Tests

The DL9000 series can be configured without the optional internal HDD. For units without the HDD, it is both easy and fast to securely erase all the data in the unit. Therefore, you do not have to worry about your confidential test results being transferred to a different location, along with the unit.
 


A Small Footprint Means More Room on Your Bench for the DUT

The DL9000 is only 35 cm wide and 18 cm deep so it does not take up all your valuable bench space. And it weighs only 6.5 kg so it is easy to move from one bench to another.





 
1 GHz oscilloscope depth comparison
                1 GHz oscilloscope depth comparison

 


 

Flexible Acquisitions

Tm Dl9000 07The DL9000 signalXplorer is Yokogawa's 10(X)th generation digital oscilloscope. It allows users to select the most appropriate memory setting for a given measurement and then acquires and displays long and short memory records quickly, saving the waveforms to its segmented memory. Advanced memory handling ensures that you get all the benefits of a long memory scope regardless of the record size you allocate for each acquisition. This is made possible by the state-of-the-art ADSE (advanced data stream engine) ASIC.


Burst signal capture scheme
Tm Dl9000 08
Example of shorter memory acquisitions (I2C SDA signal capture): by skipping portions of a signal which contain no information, many frames can be acquired in the memory.

Mega word signal capture example (TV composite signal): 1 whole TV frame can be captured without losing detail.

 

 


 

 

History Replay    

When acquisition stops and there are more than two acquisitions in memory, the HISTORY key is illuminated. At that time, you can use the rotary knob to view every single acquisition in memory, one-by-one, and look for an anomaly. The new History Replay function allows you to play back the waveforms in memory in the same way you play back video on a DVR.
 

History memory - access method
Tm Dl9000 09
 
Tm Dl9000 46Reviewing each acquisition one by one Tm Dl9000 45
Playing back history memory continuously
 
 

ADSE Offers Two Fast Signal Acquisition Modes      

N Single ModeTm Dl9000 10
When you need to observe closely-spaced waveform events consecutively, it is important to minimize the dead time between captures. The 'N single' mode on the DL9000 captures up to 1,600 waveforms on each of 4 channels with as little as 400 ns of dead time between acquisitions. In the 500 ps/div range, this corresponds to an effective acquisition rate of 2.5 M waveforms/sec/ch.

New ACCUM (accumulation) mode
When observing long-term repetitive waveform events, the ACCUM function offers a fast repetitive signal acquisition rate of up to 25 k waveforms/sec/ch (on 4 channels simultaneously) while retaining up to 2,000 acquisitions in memory.

Whether you use N single or the ACCUM function, previously acquired waveforms are stored in memory and can be accessed using the History Function.
Search Function
   

 


 

Search function

Tm Dl9000 11Both Zoom search and History search functions are available in the signalXplorer. Zoom search locates an area of interest in a single acquisition. History search locates any acquisition in history memory that meet user-selected criteria.











  

 


 

Dot density display    

Tm Dl9000 12The intensity of individual display pixels are varied depending on how often a signal illuminates each pixel. Even for single shot acquisitions, Dot Density Display provides visual information about the S/N ratio of a signal. For repetitive signal acquisitions, this feature offers additional insight into the frequency of occurrence of portions of a signal over time. In short, Dot Density Display technology offers analog oscilloscope-like waveform representations on a digital scope.



 

Enhanced Analysis & Math

 

Histogram displays
Tm Dl9000 13Tm Dl9000 15Gain new perspectives on your waveforms by using time and voltage histograms. For example, signal jitter can be shown using a time histogram, and noise on DC signals can be visualized using a voltage histogram.    


Tm Dl9000 14




  
Example: result of time histogram

 

 


Statistics

Tm Dl9000 16Tm Dl9000 18Use the statistics functions to generate statistical information (max, min, avg, std dev, etc.) about waveform parameters. Continuous statistics (running statistics on selected parameters during acquisition), Cycle statistics (statistical information about a waveform on a cycle-by-cycle basis) and History statistics (statistics on waveforms captured in history memory) are all available.    
Tm Dl9000 17
Example: cycle statistics
   

 

 


 

FFT

Tm Dl9000 13Tm Dl9000 21The DL9000 series can calculate FFT waveforms using up to 250 k points. To scale the results, you can specify the center frequency and the frequency span, just like you would do with a spectrum analyzer.    


Tm Dl9000 19        Tm Dl9000 20
250 k point FFT                                          Scaled FFT result

 

 


 

 

Trend displays

Tm Dl9000 13Tm Dl9000 44Track long-term waveform parameter trends using the trend display. The Trend display can be used to visualize fluctuations of a selected parameter.    

 


Tm Dl9000 22
Example: Trend display of P-P values

 

 

 


 

 

Mask testing

Tm Dl9000 16Tm Dl9000 25With free Mask Editor Software, you can define a mask and then test to see whether or not the measured signal falls in/out of the mask. Masks for a variety of communication signals can be defined.    





Tm Dl9000 23    Tm Dl9000 24
Example: Telecom test                                        Example: Mask Editor Software

 


 

Waveform math

Tm Dl9000 26Tm Dl9000 28Define up to 8 math traces. Functions include: filtering, +, -, x, Integration, Edge Count and Rotary Count. Basic arithmetic functions are performed using the ADSE (hardware) and results are displayed in real time.    

Waveform math


Tm Dl9000 27
Math trace example


Real-time analog/digital filtering

Tm Dl9000 26Tm Dl9000 31Real-time filtering     200 MHz and 20 MHz analog low pass filters and 8 MHz, 4 MHz, 2 MHz, 1 MHz, 500 kHz, 250 kHz, 125 kHz, 62.5 kHz, 32 kHz, 16 kHz and 8 kHz digital low pass filters are available for real-time filtering. These filters can be applied to live signals without slowing down the signal acquisition rate. Additional types of digital filtering are available using the math function.

Tm Dl9000 29Tm Dl9000 30
Signal without filter            Signal with filter

 

 

Connectivity

Use USB 2.0 interface (standard), 100BaseTX /10BaseT (option), or GPIB (available using a National Instruments NI PCMCIA-GPIB card) to remotely control the DL9000 and to transfer waveform data from the scope. The industry standard USBTMC-USB488 with USB 2.0 interface offers data transfer rates that exceed typical GPIB data transfer rates.
For data storage, you can use a PC card drive (available in both front and rear panels) or USB interface. These interfaces support media such as CompactFlash, PC Card type II HDD, and USB memory
Connectivity
Tm Dl9000 33
Tm Dl9000 32
 
GPIB interface
(Two PC card interfaces are standard. However, a NI PCMCIA- GPIB card is required for communication. You can use the front or back panel PC Card interfaces for this purpose.)

 

 

 

 


PC Card/USB interfaces

 

 

Tm Dl9000 34 Tm Dl9000 35 Tm Dl9000 36


Use popular, widely available, large capacity media such as CompactFlash or USB HDD to save and transfer waveform data captured with the DL9000.
A USB mouse and/or keyboard can be used to facilitate operation of the unit. The front USB port can also be used to connect to a USB printer.

 

 

 

Comes Standard with a Wide Variety of Dedicated CAN Bus Triggers

--- CAN Bus Signal Analysis Function (/F7, /F8 Option) ---
Dedicated triggers for CAN Version 2.0A/B (high speed and low-speed CAN bus signals; used extensively for the internal busses of automobiles, factory automation equipment, medical devices, and other application) and CAN bus signal protocol analysis function are available as an option on any DL9000 series instrument. A number of triggers and powerful analysis function for CAN bus come together in a instrument. Two models of differential probes are available for CAN measurements (sold separately).
  
Tm Dl9000can 01The DL9000 applies triggers based on a variety of specified conditions, enabling reliable capture of only the desired CAN bus signals. It offers Start of Frame, ID, and Data conditions, combinations of these conditions, and Remote Frame and even set up to four CAN ID/Data conditions, combined with OR logic, and trigger if any of the conditions occur. You can also set conditions relative to a specified trigger Data value such as True/False, Greater than/Less than Data value, between two(2) data values, or out of Data range.

 

 

 

Data trigger setting example

Combination Triggers

Dl9000can Comb Combination Triggers: Create triggers consisting of CAN events and events on other channels (Event Interval Trigger)
  • Trigger on Combinations with Non-CAN Signals
    Triggers can be activated on combinations of CAN and analog signal trigger conditions. For example, you can debug a system by setting up a condition in which the trigger activates on a time difference between a CAN signal trigger condition and a signal input to another channel such as a sensor or actuator operation signal.
  • Trigger on Combination of Two CAN Signals
    You can set a condition in which a trigger activates on the time difference (delay time, etc.) between trigger conditions set on two separate CAN networks. This is useful for verifying the complementary operation of two corresponding CAN sub-networks.
Setting Triggers based on combinations of two conditions (Events)

 


Supports System Debugging and Troubleshooting

(with High Speed Analysis & Waveform Display)

The CAN bus protocol analysis results list can be displayed while the waveforms are being acquired. Analysis results of frame type, time from trigger position, ID, DLC, Data, and CRC, and Ack/Non-Ack are aligned in a single screen with their corresponding waveforms, enabling you to easily compare waveform quality and bus protocol together. You can capture waveforms and analyze the data in real time at update rates of approximately fifteen times per second.* You can save the analysis results (list) to a text file in CSV format.

* During continuous measurement at 5 ms/div and a record length of 1.25MW.
(Update rates will vary, depending on setup conditions.)

 

 

Tm Dl9000can 02
Waveform Display and Analysis Results
Tm Dl9000can 03
   Detailed Analysis Results

 

 

 


 

Simultaneous Analysis & Display of Tow Different CAN Bus Signals

Tm Dl9000can 04You can analyze two CAN bus signals simultaneously and display the results.
For example, you can check waveforms and protocol data from two CAN sub-networks with different condition at the same time, and verify the correlation between the signals.



Two different CAN bus signals:
analyzed & displayed
simultaneously

 


 

Automatically Search Captured Signals for Specific Frames/Fields

Tm Dl9000can 05You can perform searches of the captured data by specifying Start of Frame, ID, and Data condition (or combinations of these), and Remote Frame and Error Frame conditions.
When the frames are detected that match the search criteria, the analysis list is highlighted and that portion of the waveform is displayed in the zoom window. You can identify portions of the waveform such as the ID or Data field of a specific frame and display those in the zoom area (Field Jump function).
Field jump function display
 

Auto Setup Dedicated to Serial Busses(/F5, /F7, /F8)

Tm Dl9000 60
Using the Auto setup function dedicated for serial buses, you can have the instrument automatically enter settings for record length, time axis (T/div), triggers, and analysis by simply specifying bus type and source (input) channel. After that, it will automatically display bus waveforms and analysis results (list and decoding). This frees you from tedious analysis setup.

Serial Bus Analysis: 12C, SPI, UART, CAN*, LINCAN Bus Signal Analysis Function (/F7, /F8)

DL9000 Series can perform I²C, SPI, UART, LIN and CAN bus analysis with the different available options (/F5, /F7 and /F8).
Triggers for these bus types are standard features. These functions make it easy to discriminate between partial software failures and physical-layer waveform problems when troubleshooting systems by observing the physical-layer characteristics of signals.
  • Serial data bus trigger functions
    A wide range of trigger conditions can be set, including triggers based on ID-Data combinations and combinations of a serial bus trigger and a regular edge trigger.
  • Real-time bus analysis-up to 15 updates/sec
    DL9000 Series displays protocol analysis results while bus signals are being captured.
  • Simultaneous analysis of different buses
    With the Dual-window Zoom function, DL9000 Series can simultaneously analyze and display the waveform of buses running at different speeds.
  • Decode Display
    Analysis results can be displayed not only in a list, but also shown as a decode next to the waveform.
Tm Dl9000 61   Tm Dl9000 62

*: CAN trigger and CAN analysis is supported by the analog input channels.

CAN Bus Signal Analysis Function (/F7, /F8)

DL9000 Series is equipped with dedicated CAN triggers including Start of Frame, ID, Data, Remote Frame, and Error Frame. Additionally, you can now set up to four ID and Data combination bit conditions and activate triggers based on OR relationships of these combinations. With the protocol analysis results list which is shown in a time series fashion, you can check each frame's analysis results (frame type, time from trigger point, ID, DLC, Data, and CRC), presence/absence of Ack, and the association with corresponding waveforms in a single screen. You can specify the type and other characteristics of fields and frames and search for corresponding waveforms in the captured CAN frame data.
Tm Dl9000 66
Waveform Display and Analysis Results

LIN Bus Signal Analysis (Added to the /F7 and /F8 Option)

Triggering and analysis functions for LIN bus (widely used as an in-vehicle LAN protocol for car body applications) are available on the DL9000 Series. It is equipped with Break + Synch trigger. You can check waveforms and the protocol analysis results (list) along with the error information (Parity, CheckSum, TimeOut, etc.). You can analyze both LIN revision 1.3 and 2.0 conformity data existing on the same bus line simultaneously.

* LIN bus analysis function supported with firmware version 2.40 or later (/F7 or /F8 option).

Tm Dl9000 67
Simultaneous analysis and waveform (decode) display of CAN and LIN bus signals

I²C and SPI Bus Analysis (/F5, /F8)

This option enables, analysis, and search on I²C and SPI
serial data bus signals. Observing the physical signals of these buses allows you to more effectively separate hardware related problems from software related problems.

With the new firmware version 4.42 or later, the SPI analysis function without CS(Chip Select) source assignment is available. Some SPI bus applications do not require CS signal. Also, the data field size and the enabled bit range for analysis can be specified. The DL9000 DSO series can be applied for more wide-ranging SPI application.

(I²C and SPI triggers are standard)
Tm Dl9000 68

  UART Signal Analysis (/F5, /F7, /F8)

General-purpose UART trigger and analysis can be supported.
The UART trigger function can trigger on stop bit of each data frame. Analysis number, time from trigger position, binary and hexadecimal notation of data, errors, and other added information can be linked with the waveforms and displayed in the same screen as analysis results. The UART analysis results can also be displayed in ASCII. Grouping display is supported for easy identification of serial messages over 2 bytes.
 Tm Dl9000 63
UART Trigger
    Tm Dl9000 64
Grouping displays
 
 Tm Dl9000 65
Example of UART analysis

 


 

Built-in Printer (/B5)

Tm Dl9000 40 This built-in thermal paper printer provides a convenient way to print out what is shown on the DL9000's display.





 

 


 

Probe Power (/P2)

 

 

Tm Dl9000 41










 
 

 These ports supply power to the following current probes (701932, 701933) and the following differential probes (701920, 701921, 701922, 700924, 700925)

Note: You do not need this option to power the 2.5 GHz active probe (PBA2500).

 

 

 

 

 

 

 

100 Base TX/ 10 Base T Ethernet (/C10)

Tm Dl9000 42 100 BaseTX/ 10 BaseT Ethernet (/C10)

Network file server/client functions and network printing are supported through Microsoft network file sharing. The SMTP client allows you to send e-mail from the unit. (/C10)

 

 


 

Power Supply Analysis Function (/G4)

Parameter Measurements and Statistical Computations
for Power Supply For Example: Power and Power Factor

Simply select voltage and current channels in a dedicated setup menu to add power-specific parameters to the waveform parameters of the selected channels. See the specifications on the reverse side of this leaflet for the dedicated parameters (types) that are added. You can also calculate the Joule-integral (I²t) required for fuse characterization.

 

Tm Dl9000 51

 


Statistical Computation and Trend Display of Cycle-by-Cycle Switching Loss

For example, in a active power factor correction circuit running in critical conduction mode, fluctuations in the switching frequency and switching current of the modulating signal, relative to the input voltage of the commercial power supply, can be displayed simultaneously along with the input voltage waveform.
The figure on the left shows data from multiple cycles of voltage (Vds), current (Id) and the computed switching loss (Vds x Id) (M1 waveform). Loss can be calculated for each cycle within a specified range of the M1 waveform (the Iteg TY parameter), and the integrated value can be quickly computed. The DL9000 also lets you view cycle-by-cycle switching loss in a list or as a trend line. Variations between power on and steady operation can easily be seen.
Tm Dl9000 52

 

 


 

 

Measuring Switching Loss with HIstory Statistics

With high speed acquisition (max. 2.5 million waveforms/sec.) and the history statistics function, you can compute statistical values and total loss of the switching loss waveforms across multiple intervals. By specifying a computation range, you can also compute the loss when switching ON and OFF, separately.

 

 

 

The number of history waveforms (Cnt = number of switching cycles) and their statistical computation results are displayed in the figure to the right.

Tm Dl9000 54

Tm Dl9000 53
The difference in the current probe and voltage probe signal propagation time (skew) can be automatically corrected. This is useful for accurate measurement and computation of switching loss. A deskew correction signal source (model 701935, sold separately) is available.  Tm Dl9000 55

 


 

Dedicated Waveform Computations for Power Supply Analysis

Quickly perform waveform computations of active power, impedance, and Joule-integral (I²t), and display the resulting waveforms. Simply select the desired function and source input channels from the menu to display the computed waveform. Tm Dl9000 56
 

Harmonic Analysis of Power Supply Current Based on EN61000-3-2

Harmonics generated by the target device under test are compared to the harmonic values allowed in by the IEC standard, based on the applicable class of device (classes A-D). Bar graphs and lists can be displayed for comparing the harmonic limit levels and the actual measured harmonic levels. Measured harmonic levels exceeding the specified limit are highlighted for easy identification.
 


                           Tm Dl9000 57

 

 


 

 

User-Defined Computation (/G2)

(The power supply analysis function option (/G4) includes the user-defined math option (/G2).)

 

Four user-defined waveforms can be defined (MATH1-MATH4) and used simultaneously in computations. In addition to a wealth of computation functions, twenty-six measurement parameters can be used in the equations. For example, you can normalize data using the amplitude of a measurement parameter. Up to 6.25 MWords per channel can be computed. Math waveforms can also be used in X-Y graphs, FFT displays, histogram analysis, and other functions.


Tm Dl9000 58

Tm Dl9000 59

 /C12 LXI Compliant Ethernet Interface Options

Lxi Logo

LXI (Lan eXtensions for Instrumentation) is a communication platform for test & measurement instruments, built on LAN technology. It provides improved transfer speeds with improved usability and low cost, when compared to traditional instrument interfaces. It's easy to migrate over from traditional GPIB system, because LXI utilizes existing technologies such as VXI-11 or IVI.

The Yokogawa DL9000/DL9700/9500 series and SB5000, with the LXI compliant Ethernet option (/C12) installed, are fully compliant with LXI Class C.

Currently, over 20 test and measurement manufacturers provide LXI compliant products, and the total number of supported products is above 1100. As a new communication platform for applications requiring high transfer speed, low cost and usability, LXI will become more widespread in the future. For more information on LXI, please visit the LXI Consortium.

Model Description
DL9040 500 MHz BW, 5GS/s, 2.5MP/ch, 4 channel
DL9040L 500 MHz BW, 5GS/s, 6.25MP/ch, 4 channel
DL9140 1 GHz BW, 5GS/s, 2.5MP/ch, 4 channel
DL9140L 1 GHz BW, 5GS/s, 6.25MP/ch, 4 channel
DL9240 1.5 GHz BW, 5GS/s, 2.5MP/ch, 4 channel
DL9240L 1.5 GHz BW, 5GS/s, 6.25MP/ch, 4 channel

701920 Differential Probe 12V / 500 MHz

  • 701920 Oscilloscope Differential Probe
  • DC to 500 MHz
  • 10:1
  • Max. Input Voltage:(to ground) ±40 V (DC + AC peak)
  • Max. Differential Voltage ±12 V (DC + ACpeak)
  • Probe power supply
  • 50 Ω input system oscilloscope

701924 Differential Probe 25V / 1 GHz

  • 701924 Differential Probe
  • 1 GHz, 50:1, Max. Differential Voltage: ±25 V (DC + ACpeak), Probe Power: dedicated probe interface

701928 Current Probe 100 MHz / 30 ARMS

701928 current probe

Front-end powered

Recognized automatically

Adjust zero position from operation of DLM2000, DLM3000, DLM4000, DL6000/DLM6000, DL9000/DLM9000, SB5000

701929 Current Probe 50 MHz / 30 ARMS

  • 701929 Current Probe 50 MHz / 30 ARMS
  • Front-end powered
  • Auto-recognized
  • DLM2000-4000, DL/DLM6000, DL/DLM9000, SB5000

701942 Miniature Passive Probe

350 MHz, 10:1, 400 Vrms, 1250 V transient over-voltage CAT I, 300 Vrms CAT II, 3 m
For DL1700E, DL7400 series

701944 High Voltage Passive Probe 1000Vrms / 400 MHz

  • 701944 High Voltage Passive Probe 1000Vrms / 400 MHz
  • For DL1700, DLM2000-6000, DL6000, DL9000, SB5000 series

701945 High Voltage Passive Probe 1000Vrms / 250 MHz

  • 3m High Voltage Probe (oscilloscope)
  • DC to 250 MHz bandwidth 
  • 100:1 attenuation 
  • Max Input 1000 Vrms CAT II 4000 V transient over-voltage CAT I

701975 50 Ω DC block for 701974

This DC block can be used to remove the DC component from an incoming signal. Use this block if you want to remove bias voltage from reaching the PBL5000 probe.

701943 PB500 500 MHz passive probe

400 MHz, 10:1/1:1, 600 V (DC + ACpeak) or 424 Vrms CAT II, 1.5 m
For DL9000, DL9700/DL9500, SB5000 series

701974 Low Capacitance Probe 5 GHz

  • 701974 Low Capacitance Probe
  • 5 GHz, 20:1 / 10:1, 20 Vrms / 40 VACpeak, 1.1 m, For DLM series
  • Low input capacitance
  • Low input resistance

700924 Differential Probe 1400V / 100 MHz

  • Differential oscilloscope probe
  • 100 MHz
  • ±1400 V (DC + ACpeak) at 1000:1
  • Internal battery or probe power supply
  • Oscilloscopes, ScopeCorders

700925 Differential Probe 500V / 15 MHz

Works with Oscilloscopes, ScopeCorders. 15 MHz, 100:1/10:1, Max. Differential Voltage: ±500 V (DC + ACpeak) or 350 Vrms at 100:1 attenuation, Probe Power: Internal battery or probe power supply.

700939 Active FET Probe 10V / 900 MHz

  • 700939 Active FET Probe
  • 900 MHz Active FET Probe Circuit
  • 10:1, ±10 V (DC + ACpeak) FET Input Active Probe
  • 1.5 m

 

701921 Differential Probe 700V / 100 MHz

100 MHz, 100:1/10:1, Max. Differential Voltage: ±700 V (DC + ACpeak) at 100:1 attenuation, Probe Power: Internal battery or probe power supply

701922 Differential Probe 20V / 200 MHz

200 MHz, 10:1, Max. Differential Voltage: ±20 V (DC + ACpeak), Probe Power: probe power supply. Works with 50 Ω input system oscilloscope.

701926 Differential Probe 7000V / 50 MHz

50 MHz, 1000:1/100:1, Max. Differential Voltage: 5000 Vrms/7000 Vpeak (1000:1), Probe Power: Internal battery or probe power supply B9852MJ power cable is bundled Work with Oscilloscopes, ScopeCorders

701927 Differential Probe 1400V / 150 MHz

  • 701927 Isolated Differential Probe
  • 150 MHz 
  • Max. Differential Voltage: ±1400 V (DC + ACpeak) at 500:1
  • Probe Power: dedicated probe interface For DLM, DL, and SB5000 series

701930 Current Probe 10 MHz / 150 ARMS

  • 701930 Current Probe 10 MHz / 150 ARMS
  • Powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply

701931 Current Probe 2 MHz / 500 ARMS

  • 701931 Current Probe 2 MHz / 500 ARMS
  • Powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply

701934 External Probe Power Supply

  • 701934 External Probe Power Supply
  • Power supply for current probes, FET probes, and differential probes
  • Supplies power for up to four probes, including large current probes

701919 Probe Stand

  • 701919 oscilloscope probe stand
  • Flexible arm, heavy base to hold and stabilize 8-13mm probes
  • Can simplify circuit board testing

B9852MJ Power Cable for Differential Probes

  • B9852MJ power probe extension cable
  • Supplies power to 700924, 700925, and 701921 differential probes from the DL probe power connectors
  • Required on DL unit
  • Only works with newer probes

B9988AE Printer paper

Quality paper for the DLM2000 /DLM4000 /DL850 /DL6000 /DL9000 and DL750

366924 BNC to BNC 1m Cable

  • 366924 BNC to BNC cable for oscilloscope 
  • 1m BNC wire
  • Simultaneous measurement with 2 units
  • Input external trigger signal

366925 BNC to BNC 2m Cable

BNC-BNC 2m. For connection to simultaneously measurement with 2 units, or for input external trigger signal.

Overview:

While accurate rise time measurements have become easier to make, it remains, nonetheless, quite easy to overlook error contributions due to not only the oscilloscope but also the probe. And, while the error contributed by a scope's finite step-response (rise time) is often accounted for, that contributed by the probe is often overlooked.

Overview:

The HDMI (High-Definition Multimedia Interface) standard is based on the DVI (Digital Visual Interface) standard. The HDMI standard has addressed the requirements for a next generation visual interface adapted by non PC applications such as DVD players or STB.

Overview:

Decimation is a technique used to reduce the total number of samples. You can use Xviewer to perform decimation on your waveform data files that have the WDF/WVF/ASCII CSV extension format. Decimation reduces the ...

Overview:

Please make sure to set Time/Div to a setting which will display a minimum of sixteen (16) Cycles.        To setup the instrument for harmonic analysis: Press the WINDOW1 key Press the Type soft key Select ...

Overview:
  • Symbol editor for the DL9000/SB5000/DLM2000 instruments
  • Two operating modes: CAN and LOGIC
  • See Symbol Editor online software download page
Overview:

The sanitation procedure for various Yokogawa oscilloscopes have been documented below. Please download the document or pdf that refers to your Yokogawa oscilloscope.

Overview:

The Yokogawa .SNP file is a proprietary Yokogawa file format for saving waveform snapshots. This file has no relation to the Microsoft Snapshot Viewer program. The .SNP file can only be viewed on the oscilloscope.

Overview:

There are two methods to programmatically determine if the calculations for waveform parameters is completed on the DL series oscilloscopes. Send the :MEAS:WAIT? command. This will ensure that no other commands are ...

Overview:

Yes, the HDMI pinout carries the I2C on pins 15 and 16 of the HDMI connector cable. The HDCP (content protecting encryption keys) signal is carried on pins 15 and 16.

Overview:

Any DL9000 Digital Oscilloscope with firmware version 1.82 or older will require a one time upgrade via FAT-16 PC Card. After applying the one time upgrade, any subsequent new firmware update can be performed via USB flash drive. Please see ...

Overview:

To use wireless mouses or keyboards on a device, a driver needs to be installed. Yokogawa instruments will not let you install drivers on the device, therefore it is not possible to connect a wireless mouse or ...

Overview:

Please download the attached article. This article discusses the three types of display interpolation found in the Yokogawa DL9000 and SB5000 Digital Oscilloscopes. It is also applicable to other Yokogawa Oscilloscopes.

Overview:

Currently, the SB5000 and DLM2000 series oscilloscopes provide the CAN Bus symbolic decode analysis function. Once the zooming magnitude is enlarged, the indication appears automatically. The DL9000 does not provide CAN ...

Overview:

The free software DL-GATE can be used for the following products only:DL1700E seriesDL7400 series (firmware version after 1.32)DL1600 series (firmware version after 1.13)DL750 series (firmware version after ...

Overview:

When communicating or controlling the DL7400 Digital Oscilloscope via USB in LabVIEW, you must use the USB driver files provided by NI-VISA (Version 3.0 or later). The Yokogawa USB driver files labeled YKUSB or YKMUSB can be used when ...

Overview:

Frequency to Voltage Conversion   Problem: A transducer produces a sine-wave output dependant on the voltage-input; here is how to decode that output with a scope or a ScopeCorder.  For 3kV input, the transducer ...

Overview:

The DLM2000 Series mixed signal oscilloscopes are capable of performing enhanced parameter measurements and calculations. This feature allows you to perform automated measurements of waveform parameters of two different areas. It ...

Overview:

The DL series instruments are capable of measuring the delay between traces or the delay between channels. The measured output value can be displayed in either time or degree. To setup the DL850 Scopecorder to measure delay, follow ...

Overview:
  • Lowest possible device setting for sample rate on Yokogawa DL850 ScopeCorder is 5 Sa/sec
  • Methods for much lower sample rates
  • External clock, etc.
Overview:

The AC Power Input in all Yokogawa instruments is designed as a 3-pin connection (one of which is a GND pin). In some parts of the world, PCs are sold with AC power cables that are 2-pin. Often times this means the ...

Overview:

We do not have an instruction manual describing the *.WDF file format structure like we did for the *.WVF files.

We provide a list of support options with more details. 

Overview:

High Resolution mode can be used to remove high frequency noise and increase vertical resolution. It achieves this by increasing the number of effective bits per data to 12-bits through digital and bandwidth filters.

Overview:
  • Unbalanced input, balanced input, isolated input, and differential input
  • Types of inputs guide presentation
  • Related products and solutions
Overview:

The measured propagation delay for the PB500 500 MHz Passive Probe (701943) is approximately 8.2 ns. A simple way of measuring the propagation delay, using the DL9000, is to measure the delay between two ...

Overview:

Even though the display record length is shorter than the specified record length, measurement is made over the full record length. There is no function that allows you to move the display position to view the other ...

Overview:

The Time Axis Accuracy is the accuracy of the A/D clock. It is not possible to directly measure the A/D clock and the A/D clock is not output from the ScopeCorder DL850/SL1400. To verify the accuracy of the A/D clock, you will ...

Overview:

Question:If the DL9000 Oscilloscopes is in normal trigger mode and no waveform acquisitions have been made i.e. the scope has not triggered, a query to the instrument using the :Waveform:Record or :History:Record? Minimum it returns ...

Overview:

Yes, the NAK CAN Bus Trigger is supported on the DLM2000 Mixed Signal Oscilloscope and DL9000 Digital Oscilloscope.  DL9000: Refer to the IM 701310-51E (page 3-13)DLM2000: Refer to the IM 710105-02E (page 2-16) 

Overview:

Although the DLM2000/DL9000 Mixed Signal Oscilloscope does not have a BoxAvg acquisition mode, there is an alternative method for achieving the same effect. The combination of Hi-Res mode and a low pass bandwidth filter will work in the same ...

Overview:

If your DL series oscilloscope is not measuring rise or fall time, it may be because you are attempting to measure asymmetric waveforms. It is not possible to perform automatic rise or fall time measurements on DL ...

Overview:

In general, the recommended sampling rate for CAN bus or I2C analysis is 10x the bit-rate. If the waveform is not noisy, the sampling rate can be set to around 4-5x the bit-rate.

Overview:

Unfortunately we do not have an automated program for adjusting the DL9000 digital oscilloscope is it is failing calibration. Please follow the procedures on the DL9000 service manual or the CE handbook.

Overview:

The Header Size entry, for a ASCII format data file, denotes the number of header lines in the header part of the ASCII File.

Overview:
  • The Offset function vs. the Position function
  • Set vertical position of a waveform in voltage value (v)
  • Set horizontal location of a waveform in division value (div)
Overview:

You can express any arbitrary exponentiation, in Xviewer or DL series instruments, by using the LOG (common logarithm) and EXP (exponential) functions. For example, for C1 raised to the exponent of 0.2, the math ...

Overview:
  • DC Precision when changing the DC waveform position setting on DL1600
  • How to calculate DC offset voltage
Overview:
  • Xviewer can open multiple files from different DL, SL, and WE series instruments into a single window display 
  • Same sample rate, trigger position, record length
Overview:

There are three kinds of standards for which a differential probe is necessary:  FlexRay CAN UART (Some but not all UART)  It is not necessary to use a differential probe for the LIN, I2C and SPI standards.

Overview:
  • "Beat Method" for Inspecting an Oscilloscope’s Time Base Accuracy
  • Inspect and verify time base accuracy
  • Aliasing effect to create a "beat waveform." 
  • Time base setting formula
Overview:

No, the DL9000 cannot be upgraded or modified to a SB5000.

Overview:

If you selected Decimation or P-P Compression when saving waveform data in ASCII CSV format, then the HResolution will not be equivalent to the Sampling Rate. If Decimation or P-P Compression is not selected, then ...

Overview:

The true noise floor of a Yokogawa oscilloscope is ≤ 2-3mVpp. The DL9000 Digital Oscilloscope, for example, has approximately 280uV residual noise at 2mV/Div with input termination set to 50Ω. The residual noise may be measured by ...

Overview:

The IEC Harmonic analysis on the DL/DLM series oscilloscopes provides a rough analysis and estimation for harmonic testing. The scope will perform an FFT on the current waveform and can be used to measure the general ...

Instruction Manuals
Software
Firmware