Space Satellite-Based Optical Amplification Measurements

Introduction

Lack of reliable high-speed internet access in rural regions, due to complicated logistics and the considerable costs involved to extend land-based networks to these areas, has inspired a wave of next-generation applications that will provide greater accessibility and reliability. Making use of “space laser” networks, these revolutionary solutions can relay digital traffic via low Earth orbit (LEO) satellite systems to provide low-latency, high-speed broadband services to communities typically beyond the reach of standard wireless and fiber networks.

Used in traditional optical transmission networks, the amplification technique of employing erbium-doped fiber amplifiers (EDFA) to directly amplify optical signals (without conversion to electrical signals) has now expanded to help boost laser-based signals for orbiting satellite communication networks.
 

Optical amplifier measurements

Optical amplifiers are primarily evaluated with gain and noise figures (NF) via an optical spectrum analyzer (OSA) to measure the optical spectra of input, using Trace A and Trace B respectively. For select applications, a polarization scrambler is placed before the OSA to reduce the effects of the OSA's polarization dependence.

Configuration of Optical Amplifier Measurement | Space Satellite Based Optical Amplification Measurements | Yokogawa Test&Measurement
Figure 1. Basic configuration of an optical amplifier measurement
 

To obtain accurate gain and NF, it is necessary to exclude the source spontaneous emission (SSE) of the light source being amplified. The gain and NF is then calculated for each channel of the input optical signal. As needed, analysis parameters such as channel detection and amplified spontaneous emission (ASE) level detection should be incorporated to hone results. This can be applied to dense wavelength division multiplexing (DWDM) systems as well.
 

Example EDFA-NF Analysis Results | Space Satellite-Based Optical Amplification Measurements | Yokogawa Test&Measurement
Figure 2. Example EDFA-NF analysis results
 

Pre-measurement steps

To accurately measure the characteristics of an optical amplifier, perform the following steps first:

Step 1: Optical Alignment and Wavelength Calibration

Connect the internal calibration light source out to the optical input port with a single-mode fiber. If an internal calibration light source is not present, calibrate using a single wavelength light source with stable output, such as a DFB-LD.

Step 2: Resolution Calibration

Calibrate the resolution bandwidth of an OSA to the equivalent noise bandwidth (required by IEC standards for optical amplifier measurement) using an external light source. Resolution calibration is recommended due to the filter response of an OSA not typically being rectangular. Because of this, the resolution bandwidth (defined as FWHM) differs slightly from the equivalent noise bandwidth. This step is especially effective when wavelength resolution is 0.05 nm or less (e.g., the difference becomes prominent). With an external light source, use a stabilized single-mode laser light source with an output power of -20 dBm or more, a level stability of 0.1 dBp-p or less, and output line width of 5 MHz or less.

Step 3: Absolute Power Calibration with an Optical Power Meter

Next, calibrate the absolute power reading of the OSA. For the measurement light source, use a single-wavelength light source with stable output, such as DFB-LD and calculate the power correction factor (PCF) using the formula PCF (dB) = P_OPM (dBm) - P_OSA (dBm), where P-OPM is the optical power value on the optical power meter and P-OSA is the spectral peak power value on the OSA.

Step 4: Optical Power Correction (Power Offset)

If optical connectors, splitters, or switches are inserted between the light source and the EDFA input or between the EDFA output and the OSA, researchers must compensate for those losses. After calibrating the absolute power using an optical power meter, double check if there is extra loss that causes errors in the absolute power reading. If additional losses in the input and output paths of EDFA are uncovered, adjust correction values based upon interpolation.
 

Analysis parameters

Depending upon EDFA analysis needs there are multiple parameters to consider. The most-commonly used include:

Signal power

Optical amp gain and NF are obtained after measuring the signal power via the optical amp (as the output light leaves the optical amp). Peak setting is typically employed because a continuous wave (CW) laser light source is used for the EDFA measurements.

Interpolation

Because amplified spontaneous emission (ASE) generated by an optical amplifier is superimposed on the output light, it is important to measure this noise component separately in optical amplifier evaluation. Optical amplifier analysis identifies the ASE component using the curve fitting and interpolation methods.

  • ASE algorithm Use the ASE power calculation algorithm with the defined range of ASE data used for interpolation.
  • Fitting algorithm Optical amplifier analysis identifies the ASE component using the curve fitting and interpolation methods. In addition, the curve fitting method and analysis conditions can be set according to the actual spectrum, so the gain and NF can be obtained accurately.
  • NF calculation Calculating NF involves equations that use the refraction index, speed of light, Planck’s constant, gain value, and ASE power. NF formulas from the IEC 61290-10-4:2007 spec are shown below.
  • Resolution bandwidth When selecting the most suitable measurement method that ensures an accurate NF value, always refer to the operations manual and/or supporting technical documents for the OSA in use.

 

EDFA-NF analysis compliance to IEC 61290-10-4:2007

IEC-based calculations for optical amplifier test methods using multichannel parameters (interpolated source subtraction with an OSA) utilize optical power (dBm), optical frequency (Hz), and frequency resolution (Hz) for EDFA analysis.

 

Automated EDFA Test

An EDFA auto-test system can easily be established in conjunction with Grid TLS, optical attenuator, and optical switches. This system does not require manual reconfiguration of optical paths and adjustments of EDFA input power, and that improves measurement throughput and avoids human error. AQ2200 series is a modular system suitable for building such a system.

Screen Shot 2016 03 28 At 10.43.25 AM
Example of automated EDFA test configuration

 

Conclusion

The general amplifier gain and NF measurement principles are well-established for traditional land-based optical networks that use fiber as the transmission medium. With the push for greater accessibility and more reliable and affordable networking services, EDFA analysis algorithms with optical amplifiers have shown to be directly applicable in free-space applications as well. The tried-and-true technologies and test methods that revolutionized long-haul optical transport networks in decades past are once again pioneering communications with cutting-edge laser-based orbiting satellite networks.

Related Industries

Related Products & Solutions

AQ2211 Frame Controller (3 Slots)

  • Easy-to-view color display
  • USB port for data storage
  • Remote monitoring and measurement through a LAN

AQ2212 Frame Controller (9 Slots)

  • Easy-to-view color display
  • USB port for data storage
  • Remote monitoring and measurement through a LAN

AQ6360 Telecom Production 1200 - 1650 nm

  • 0.1 nm resolution
  • ±20 pm accuracy
  • 55 dB dynamic range
  • -80 dBm level sensitivity
  • High sweep speed for manufacturing

AQ6370D Telecom Optical Spectrum Analyzer 600 - 1700 nm

  • AQ6370D Optical Spectrum Analyzer
  • Popular TELECOM wavelength Range of 600nm to1700nm
  • Ideal model for Telecommunications applications for single-mode and multi-mode optics

 

AQ6373B Visible Wavelength Optical Spectrum Analyzer 350 - 1200 nm

  • Dedicated SHORT wavelength Range of 350nm to1200nm
  • Accurately measure visible spectrum of 380nm to 780nm
  • Bio-sciences and beyond
  • Measuring 1064nm Nd:YAG, DPSS Laser sources

AQ6374 Wide Range Optical Spectrum Analyzer 350 – 1750 nm

  • AQ6374 Wide Range Optical Spectrum Analyzer
  • Covers wavelengths from 350 to 1750 nm
  • Visible lights (380 to 780 nm) and telecommunication wavelengths

AQ6375B Long Wavelength Optical Spectrum Analyzer 1200 - 2400 nm

High Performance LONG WAVELENGTH
The AQ6375B is a bench-top optical spectrum analyzer covering the long wavelengths, 1200 to 2400 nm, with the added benefits of gas purging input ports / output ports, a built-in cut filter for high order diffracted light, and a novel double speed mode which increases the sweep speed up to 2 times compared to the standard sweep mode.

AQ6376 Three Micron Optical Spectrum Analyzer 1500 - 3400 nm

MWIR WAVELENGTH with internal gas purge and cut filter
The AQ6376 is the latest version of our bench-top optical spectrum analyzer extending the wavelength coverage well beyond the NIR range of our previous models into the MWIR region from 1500 to 3400 nm.
Popular applications include the detection of gases such as carbon oxides (COx), nitrogen oxides (NOx), and hydrocarbon gas (CxHy) for environmental studies.

AQ6380 Highest Performance 1200 - 1650 nm and 900 - 1650 nm

  • 0.005 nm (5 pm / 0.624 GHz) resolution
  • ±5 pm accuracy
  • 67 dB dynamic range
  • -85 dBm level sensitivity

DFB Light Source, 1 or 2 CH (AQ2200)

  • 1310, 1550, 1625 or 1650 nm
  • Output level:  ≥10 dBm
  • Level stability: ±0.005 dB or less

ITU Grid Light Source C/L band, 1 or 2 CH (AQ2200)

  • C-band or L-band
  • 1 MHz step fine tuning
  • Output level: ≥12.5dBm

Optical Component Test System

  • Modular platform for automated optical testing
  • Attenuators, switches, power meters, light sources, and SMUs

Optical Power Meter (AQ2200)

  • Single channel with analog output
  • 800 to 1700 nm
  • -90 to +15 dBm

Optical Power Meter 2CH (AQ2200)

  • Dual channel
  • 800 to 1700 nm
  • -90 to +15 dBm

Optical Power Meter High Power (AQ2200)

  • Single channel 
  • 970 to 1660 nm
  • -70 to +30 dBm

Optical Power Meter for Free Space Measurement (AQ2200)

  • Large diameter detector
  • 800 to 1700 nm, -90 to +15 dBm
  • 400 to 1100 nm, -90 to +10 dBm

Optical Spectrum Analyzers

  • High-resolution measurement of optical power vs wavelength
  • Ideal for R&D, manufacturing, and laser characterization
  •  

Optical Switch 1x16 (AQ2200)

  • 1x16 configuration
  • Single mode or Multi mode
  • Low insertion loss: 1.0 dB
  • Reproducibility: ±0.01 dB

Optical Switch 1x2 / 2x2 (AQ2200)

  • Dual 1x2 or Dual 2x2 configuration
  • Single mode or Multi mode
  • Low insertion loss: 1.0 dB
  • Reproducibility: ±0.01 dB

Optical Switch 1x4 / 1x8 (AQ2200)

  • 1x4 or 1x8 configuration
  • Single mode or Multi mode
  • Low insertion loss: 1.0 dB
  • Reproducibility: ±0.01 dB

Optical Test Equipment

Advanced optical testing tools engineered to validate components and systems powering today’s high-speed fiber networks and emerging photonics technologies.

Variable Optical Attenuator (AQ2200)

  • Single mode model:
    • 1200 to 1700 nm
    • 0 to 60 dB
  • Multi mode model:
    • 800 to 1370 nm
    • 0 to 45 dB

Variable Optical Attenuator with Monitor (AQ2200)

  • Built-in optical power meter
  • Single mode model:
    • 1200 to 1700 nm
    • 0 to 60 dB
  • Multi mode model:
    • 800 to 1370 nm
    • 0 to 45 dB

Precision Making

Top