701938 Passive Probe 600V / 200 MHz

Bandwidth

:

DC to 200 MHz

Attenuation

:

10:1

Input Resistance

:

10 MΩ

Input Capacitance

:

13.5 pF

Max. Input Voltage

:

600 V (DC + ACpeak) or 424 Vrms CAT II

Probe length

:

1.5 m

For use with DLM2000 (200 MHz model)

How to Use Passive Oscilloscope Probe 701938

Use adequate attachment suitable for the point to measure. Before using the probe, adjust its capacitance by tuning the trimmer.

Adjustment

1. Connect the probe connector to the input of the oscilloscope, and connect the tip of the probe to the CAL signal output terminal.

2. Change the T/Div and the V/Div to get the display shown below. And tune the trimmer to get the correct waveform.

  • Bandwidth: DC to 200MHz (-3dB)
  • Attenuation Ratio: 10:1
  • Input resistance: 10MΩ
  • Input capacitance: 13.5 pF
  • Compensation Range: unspecified
  • Rise Time: 1.75 ns max. (typical)
  • Max. input voltage: 600V (DC + ACpeak) or 424 Vrms
  • Probe Length (coax): 1.5 meter
  • Standard accessories include: ground lead, pinchers tip, IC test tip, ground attachment, marker tip


Supplied standard with DLM2000/DLM4000.
 