The DM7560 is a flexible 6.5-digit digital multimeter with high-accuracy, high-speed data logging (up to 30k S/s) with deep 100k reading memory and built-in statistical analysis.
Yokogawa understands that your test requirements and applications change quickly and unpredictably over time. Many multimeters in the market are not designed to adapt to these unforeseen situations, requiring users to purchase additional equipment when the need arises. The DM7560 fills that gap by utilizing:
A large 4.3-inch high-resolution display provides comprehensive data observation using a flexible combination of primary and secondary display areas.
The DMM7560 can show different types of visualizations on the display. In this case, the top displays a time-domain trend plot and the lower region displays statistics of this data.
Users can display the input signal voltage and frequency side-by-side with numeric values and indicators.
In bulk mode, data can be logged to the internal memory with high sample rates of up to 30 k S/s. Data logged to the memory can be copied to a USB memory device and analyzed on the PC.
* When DCV, DCI, 2 WΩ, 4 WΩ functions.
Setting the DM7560 to 30 kS/sec enables users to see the details of a 10 ms pulse width, on a 2 Vpp measurement.
An internal memory of 100 k points enables long-term, high-resolution data logging even for high sample rates. Continuous measurement of over 27 hours is possible with a sample rate of 1 S/s.
Sampling Rate (S/s) | 1 | 1k | 30k |
Logging time (h:m:s) | 27:46:40 | 0:01:40 | 0:00:03 |
Trigger events such as the measured LEVEL, LIMIT or EXTERNAL TRIGGER can stop logging. Users can specify the amount of data to store after an event occurs.
SIGNAL LEVEL events can stop data logging.
Users can transfer readings to a PC file for more detailed analysis.
By setting upper and lower limit values as the cursor position on the histogram display, user can display the number of data, ratio to whole data (%) and yield rate.
Yield rate and other calculations are available using cursor controls on the histogram display.
In the trend chart, statistic data in a selected time range can be calculated.
Statistical data such as the MAX/MIN/AVG of a cursor-specified range is calculated automatically.
Users can easily zoom to see a magnified part of the trend chart or display the zoomed region as a histogram.
Both the histogram and trend chart can display LIMIT judgment results. The number of captured NO-GO results is displayed in the histogram display, and the timing when NO-GO results were captured is clearly displayed in the trend chart.
Easily seen from a distance.
The DM7560 can store/recall up to 10 setups through the optional RS-232 interface to enable flexible control of the instrument from a PLC.
A LIMIT judgment result can be output as a signal from the DIO terminals (option) for simplified implementation of automated test systems.
In addition to the standard USB interface, Ethernet, RS-232 and GP-IB are also available. Users can program the unit using industry-standard SCPI commands.
2 pieces (red and black) in 1 set
length: 1.00 m
Used in combination with the 701959, 758921, 758922, or 758929
Rating: 1000 V CAT III/19 A
Rated at 300 V. Attaches to the 758917 test leads. Sold in pairs.
Screw-fastened adapters. Two adapters in a set. 1.5 mm Allen Wrench.