SL1000 High Channel Count ScopeCorder DAQ

The SL1000 is a modular data acquisition system that delivers independent, isolated channel hardware at high speeds up to 100 MSamples per channel, with no compromise in bit resolution, memory depth, or data streaming performance. Choose from a wide variety of I/O modules for electrical and physical sensor signal measurements to meet the needs of any high channel count application.

Selecting a data acquisition platform for electronics or mechatronics applications has always been a balancing act. High speed digitizers lack the isolation, attenuation, or bit resolution necessary for power electronics testing. PC-based platforms with fast streaming throughput sacrifice noise immunity, signal conditioning, and hardware integrity.

Until now. The new Yokogawa SL1000 is the only data acquisition system that delivers independent, isolated channel hardware at 100MS/ch rates, with no compromise in bit resolution, memory depth, or streaming performance.

Speed of managing and acquiring data is the highlight of the SL1000.

  • Fast Acquisition
    • Up to 100 MS/s on all channels (10 ns sampling interval)
    • 100 MS/s 12-Bit 1 kV¹ isolation module with 20 MHz bandwidth
    • Supports parallel testing: Perform measurements with up to four simultaneously independent sample rates
  • Fast Transfer and Storage
    • Stream data to PC via high speed USB 2.0 or 1000BASE-T Gigabit Ethernet²
    • Real time display on a PC (GIGAZoom engine)³
    • Stream data to a PC hard disk or the SL1000's internal hard disk² in real time (at speeds of 1.6 MS/s = 100 kS/s x 16ch)³ 
  • Easy to use
    • Easy to use Standard Acquisition Software
    • Quick and Intuitive operation means that you can start measuring immediately
    • Setup Wizard guides you through detailed settings
  • Can operate "Standalone"
    • Store data directly on the SL1000
  • Wide Library of Plug-In Modules
    • Eight module slots are available in each unit
    • Select from twelve different plug-in modules

¹: In combination with 10:1 probe (for isolated BNC input) model 702902 or 700929
²: Optional
³: Speed depends on PC performance and measuring conditions.


High-Speed Capture

In the pursuit of isolated high-speed waveform measurements, Yokogawa has achieved a maximum sample rate of 100 MS/s (10 ns sampling interval). The SL1000 can accurately capture high-speed and high-voltage phenomena by using the newly developed 100 MS/s, 12-Bit resolution,  20 MHz frequency range and 1-kV * Isolation Module (model 720211).
Furthermore, you can combine modules that support measurements of a variety of signals, giving you solutions for an extensive range of applications.

*: In combination with 10:1 probe (for isolated BNC input ) model 702902 or 700929

High Speed Capture

Saving Data over Long Periods of Time

Data can be saved to the SL1000’s internal acquisition memory over long durations, or it can also be streamed in real-time to a PC's hard disk or the SL1000’s internal hard disk ¹ ².

Sample Rate V Recording Time

¹:  with the /HD1 Option
²:  Maximum speed of real time hard disk recording depends on measuring conditions.
³:  Trigger mode: Single, measuring on 1 module, 2 channels.

Supports parallel testing

Perform measurements with up to four simultaneously independent sample rates. The amount of data saved on hard disk can be reduced by optimizing the sample rate for the DUT on a module by module basis.

Support Parallel Testing

High-Speed Data Transfer & GIGAZoom Function 

You can transfer data to the PC at high speeds via USB 2.0 or Ethernet 1000BASE-T Gigabit Ethernet¹. The SL1000’s high-speed data compression engine (GIGAZoom engine) displays waveforms on the PC in real time² (even with massive amounts of data at high sample rates).  It offers the same display updating and zooming performance as standalone measuring instruments.

¹: with the /C10 Option
²: The number of channels from which waveforms can be displayed during measurement may be limited depending on the PC performance and measuring conditions.

Giga Color Black R

Giga Zoom Function

Real Time Saving to Hard Disk

Continuously measured data can be saved in real time to a PC's hard disk and/or the SL1000's internal hard disk ¹. File names are assigned automatically, freeing you from time consuming file operations. Data can be saved simultaneously - and in real time - to both the PC’s and SL1000's hard disks ¹. This bolsters the reliability of your data storage system, protecting your vital data. You can access the SL1000's internal hard disk ¹ with Xviewer waveform viewer software, or through an FTP client over Ethernet ².

Real Time Saving To Hard Disk

¹: with the /HD1 Option
²: with the /C10 Option
³: Typical values. Actual values depend on PC performance and measurement conditions.

Settings for the Hard Disk Recording Function

By using the various recording features, you can efficiently and automatically record only the data you need to the hard disk. Just specify the recording destination, recording start and stop conditions, conditions for repeating recording, and other criteria. With free run mode, the specifiable parameters for the recording start condition are immediate, time, and alarm; for the recording stop condition, the parameters are continuous, time, recording time, and alarm; and for the repeating condition, recording interval and number of recordings*. With triggered mode, measured data is recorded on each trigger. You can also manually save data from the SL1000's internal acquisition memory to PC hard disk.

*: Max. file size per recording is 12 GB (recording on 4 channels, approximately 1.5 GW/ch)

Setting Hard Disk Recording Function

Multi Units Synchronization

Maximum 8 Synchronized Units

  • 100 MS/s up to 128 ch (16ch x 8 units)
  • Can use 4 different sample rates across all units
  • (Supports Parallel testing)
  • Can combine trigger and alarm for channels across all units
  • Maximum speed for saving in real time1
  • PC HDD: 1.6 MS/s = 100kS/s x 16ch > 10kS/s x 128ch (Total data transfer rate to PC HDD is 1.6MS/s) Unit HDD: 1.6MS/s = 100kS/s x 16ch (100kS/s x 128ch with 8 units)

1: Typical values. Actual values depend on PC performance and measurement conditions

Tm Sl1000 20

 

(Note)
In synchronized unit mode, recording into PC and SL1000 embedded HDD at the same time is not possible.
The recording file is per unit basis. (Utility software interface.)


Acquisition Software

Setting Marks

You can input the comments in the mark area when monitoring (Free run mode) over long periods of time.

SL1000 Software 1

Real time X-Y Display

You can now see both the T-Y and X-Y waveform Display. It is easy to evaluate data with fast update.

SL1000 Software 2 2

Auto Play

It is easy to set zoom position of waveform when measuring over long periods of time data or large data.

SL1000 Software 3 1

SL1000 Software 4

File Utility Function

You can save the data in both ASCII and Binary format. You can also load data with the same analysis program (ex. MATLAB).

SL1000 Software 5

Setting Operation Display

Accumulating Waveforms

You can easily detect unevenness or changes in acquired data.

SL1000 Software 6

Sample of Accumulate Display

Setup Wizard Makes It Easy

The Wizard automatically recognizes any connected SL1000 and its' plug-in modules. Just click the Start button to start measuring right away - no complicated settings to enter. The four screens of the Setup Wizard guide you easily through detailed settings for configuring the system, measuring, saving and displaying. Of course, you can save and recall your settings at any time.

Setup Wizard

Individual Sample Rates for Each Measurement Channel Group

Up to four groups of measurement channels can be defined with individual measurement conditions and display settings. Even waveforms from groups with different sample rates can be displayed in the same window.

Individual Sample Rate

Easy Tabular Setup Screens

Measurement conditions and channel display settings can be viewed and set easily using a tabular format. Use drag and drop shortcuts to quickly setup multiple channels.

Easy Tabular Setup

Measurement condition setting screen Display setting screen

Control Buttons - Just Like Your DVD Remote

Measurement and saving can be started and stopped using the same familiar buttons found on a DVD remote control. Start using the instrument on the same day you receive it, with absolutely no programming required.

Control Button

Real Time Waveform Display and Analysis

You can display a zoomed portion of the waveform simultaneously with the overall waveform during triggered measurement. Even during live recording, you can use the display hold * to review past data. You can also perform cursor measurements or automated measurement of waveform parameters (up to 26 during triggered measurement) in real time.

*: The display hold may automatically switch to display resume depending on the measuring conditions.

Easy Display Setup

Adjust your vertical display scale with ease using mouse shortcuts.

Tm Sl1000 21

File Transfer

Adjust your vertical display scale with ease using mouse shortcuts.The File Transfer Function transfers files from the SL1000 to PC via, the Acquisition Software, intelligently in the case of multiple synchronized units.

Tm Sl1000 22

File Utility *

SL1000 File Utility is file processing software for manipulating acquired files before analyzing waveforms with Xviewer. It can also analyze multiple channels across several units at the same time.
* SL1000 File Utility is bundled with the SL1000 standard install CD.

Tm Sl1000 23

File interface operation screen (example)

Tm Sl1000 24

Xviewer / XviewerLITE

Xviewer is a PC software application designed to work with Yokogawa’s digital oscilloscopes and ScopeCorders.

MATLAB WDF Access Toolbox

MATLAB WDF Access Toolbox enables the access to waveform data files saved in WDF format on MATLAB.
To control the instruments on MATLAB, please use Instrument Control Toolbox provided by MathWorks.

July 26, 2017
  • Released new firmware version 2.40

720211 High-Speed 100 M/s, 12-Bit Isolation Module

High-Speed 100 MS/s 12-Bit Isolation Module (2 channels) 
IsoPRO technology enables 1kV isolated measurements in combination with 700929 or 701947 probe and is designed for inverter / IGBT related applications in mind. Using high speed optical fiber-based transmission, the module achieves high speed ADC clock and data isolation and provides the performance needed to develop high efficiency inverters, which employ high voltages, large currents, and ever increasing switching speeds.
Applicable to DL350, DL850 series, DL950 and SL1000.

720250 Voltage Module 10MS/s

  • 720250 Voltage Module
  • 10 MS/s sample rate
  • 12-bit resolution
  • 3 MHz bandwidth
  • 2 isolated channels
  • DL350, DL850, DL950, SL1000

720281 Frequency Module

  • 720281 Frequency Module
  • 1 MS/s sample rate 16-bit resolution
  • 2 isolated channels
  • 420 V*2, 42 V*3 max input voltage
  • ±0.1% DC accuracy
  • 0.01 Hz to 500 kHz measurement frequency

701947 Isolated Probe 1000V / 200 MHz

  • 1.5m Isolated Probe (ScopeCorder)
  • DC to 200 MHz bandwidth 
  • 100:1 attenuation Isolated
  • BNC connector type 
  • For ScopeCorder Isolated Modules

702902 Isolated Passive Probe 1000V / 60 MHz

Passive Probe, 1000V(DC+ACpeak) CAT II, 60MHz, 10:1, 10MΩ, 2.5m
Wide operating temperature range(-40 to 85°C)
For isolated BNC input modules for ScopeCoder series

701251 Analog Voltage Input Module

  • 701251 Analog Input Module
  • High-Speed 1 Ms/s 16-Bit Isolation Module (2 ch)
  • High sensitivity range (10 mV), low noise (±100 µVtyp), high noise immunity
  • DL850, DL750, SL1000

700929 Isolated Passive Probe 1000V / 100 MHz

  • Versatile 700929 passive oscilloscope probe
  • 100MHz frequency bandwidth
  • Isolated input module of ScopeCorder series
  • For use with isolated BNC inputs

701940 Passive Probe 600V / 10 MHz

  • 701940 Passive Probe
  • 10 MHz, 10:1/1:1, 600 V (DC + ACpeak) CAT II, 1.5 m
  • For ScopeCorder Non-Isolated Modules

701255 Analog Voltage Input Module

High-Speed 10 MS/s 12-Bit non-isolation Module (2 ch)
Non-Isolation version of model 720250
Applicable to DL350, DL850 series, DL950 and SL1000.

701977 Differential Probe 7000 V / 50 MHz

  • 701977 Differential Probe for Oscilloscope 7000 V / 50 MHz
  • 50 MHz, 1000:1 / 100:1, Max.
  • Differential Voltage: 5000 Vrms and 7000 Vpeak or less

701978 Differential Probe 1500 V / 150 MHz

  • 701978 Differential Probe for Oscilloscope 
  • 1500 V / 150 MHz
  • 500:1 / 50:1
  • Max. Differential Voltage:±1500 V (DC + ACpeak)

720268 High Voltage Module 1MS/s

  • 720268 High Voltage Power Supply Module
  • 300 kHz bandwidth
  • 2 isolated channels
  • Max input (DC+ACpeak) 1000V
  • DC accuracy ±0.25%,
  • DL350, DL850, DL950, SL1000

701917 Current Probe 50 MHz / 5 ARMS

  • 701917 oscilloscope current probe
  • Frequency bandwidth: DC to 50 MHz
  • Maximum continuous input range: 5 Arms
  • Functions with Digital Oscilloscopes, ScopeCorders, other waveform measuring instruments

701918 Current Probe 120 MHz / 5 ARMS

  • Yokogawa 701918 Current Probe
  • Frequency bandwidth: DC to 120 MHz
  • Maximum continuous input range: 5 Arms
  • Functions with Digital Oscilloscopes, ScopeCorders, other waveform measuring instruments

701930 Current Probe 10 MHz / 150 ARMS

  • 701930 Current Probe 10 MHz / 150 ARMS
  • Powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply

701261 Universal Voltage & Temperature Input Module

  • 701261 Universal Module (2 ch)
  • Thermocouple (K, E, J, T, L, U, N, R, S, B, W, iron-doped gold/chromel)
  • Applicable to DL350, DL850 series, DL950 and SL1000.

701931 Current Probe 2 MHz / 500 ARMS

  • 701931 Current Probe 2 MHz / 500 ARMS
  • Powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply

701262 Universal Voltage & Temperature Input Module (w/AAF)

  • Universal Module (with Anti-Aliasing Filter, 2 ch)
  • Thermocouple (K, E, J, T, L, U, N, R, S, B, W, iron-doped gold/chromel), with AAF
  • DL350, DL850 series, DL950 and SL1000

701932 Current Probe 100 MHz / 30 ARMS

  • 701932 Current Probe 100 MHz / 30 ARMS
  • Powered by Yokogawa Digital Oscilloscopes, Scopecorders, or external power supply

701933 Current Probe 50 MHz / 30 ARMS

  • 701933 50 by 30 current probe
  • Powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply

701265 High-Precision Temperature Input Module

Temperature/high-precision voltage Module (2 ch)
Thermocouple (K, E, J, T, L, U, N, R, S, B, W, iron-doped gold/chromel), high sensitivity range (1 mV), and low noise (±4 µVtyp)
Applicable to DL350, DL850 series, DL950 and SL1000.

701934 External Probe Power Supply

  • 701934 External Probe Power Supply
  • Power supply for current probes, FET probes, and differential probes
  • Supplies power for up to four probes, including large current probes

720266 High-Sensitivity, Low-Noise, Voltage, Temperature Module

  • The 720266 Temperature Module/Voltage Module
  • 16-Bit, 125 S/s (Voltage) and 125 S/s (Temperature) sample rate
  • DL350, DL850 series, DL950, SL1000

438920 Shunt resistor

250 Ω ±0.1%, 0.3 W, ±25 ppm/ ̊C

438921 Shunt resistor

100 Ω ±0.1%, 0.3 W, ±25 ppm/ ̊C

701270 Strain Input Module (NDIS)

  • Strain Module, NDIS (2 channels)
  • 701955 or 701956 NDIS bridge head
  • Detect/display mechanical stress with ScopeCorder
  • DL350, DL850 series, DL950, SL1000

438922 Shunt resistor

10 Ω ±0.1%, 0.3 W, ±25 ppm/ ̊C

720901-01 Synchronous connecting cable

For SL1000, Cable length: 1 m

720901-02 Synchronous connecting cable

For SL1000, Cable length: 3 m

701271 Strain Input Module (DSUB)

Strain Module with Shunt Calibration, type DSUB (2 channels) to be used in combination with 701957 or 701958 DSUB bridge head.
Using the strain module and strain gauge the ScopeCorder can detect and display mechanical stress (strain). It works on the principle that the resistance value of a metal foil changes as it expands and contracts.
Applicable to DL350, DL850 series, DL950 and SL1000.

A1421WL USB Cable

Total length: 2 m
USB2.0 Hi-Speed

A1002JC NDIS Connector for 701270

  • Yokogawa Oscilloscope and ScopeCorder products
  • A1002JC NDIS connector
  • Direct connection to strain module 701270

701955/701956 NDIS Bridge Heads 120Ω/350Ω

  • ScopeCorder Accessories for DL850 series, DL750/DL750P, SL1000 & SL1400
  • 701955 NDIS Bridge Head, Bridge resistance: 120Ω , 5m NDIS cable included
  • 701956 NDIS Bridge Head, Bridge resistance: 350Ω , 5m NDIS cable included

701275 Acceleration & Voltage Input Module (w/AAF)

  • 2 channel Voltage Module/Acceleration Module
  • Anti-Aliasing Filter 
  • Direct input from built-in amp type acceleration sensor to measure acceleration 
  • DL350, DL850 series, DL950 and SL1000.

701957/701958 D-Sub Bridge Heads 120Ω/350Ω

  • 701957 and 701958 D-SUB Bridge Head
  • Shunt calibration
  • 5m DSUB cable included
  • Bridge resistance:  120Ω 
  • Bridge resistance:  350Ω 

366923 BNC to T Adapter

T-adapter for BNC connectors. Use for circuits having voltage levels no greater than 42 V.

751512 Banana (Male) to Binding Post Adapter

Safety-terminal-binding-post adapter. Use for circuits having voltage levels no greater than 42 V.

758924 BNC to Banana Conversion Adapter

For conversion between BNC and female banana plug
Applicable for DL750/DL750P, SL1000 & SL1400.

B8099NM 4mm conversion adapter

For 702902, 702906

758917 DMM Measurement Lead Set

  • Set of 0.8m long red and black multimeter test leads
  • Used in combination with a pair of optional 758922 or 758929 alligator-clip adapters
  • 1000 Vrms, 32 Arms CAT II

758933 Measurement lead

2 pieces (red and black) in 1 set
length: 1.00 m
Used in combination with the 701959, 758921, 758922, or 758929
Rating: 1000 V CAT III/19 A

701901 BNC to Safety Banana 1.8m Cable, 1:1

  • 701901 BNC to Safety Banana 1.8m Cable, 1:1
  • 1000 Vrms-CAT II, 1.8 m long
  • Safety BNC(male) to safety banana(female)
  • 701959, 701954, 758921, 758922, 758929

701906 Long Test Clip

Set contains one black and one red clip
1000 Vrms-CAT II
2 pieces (red and black) in 1 set 
Connected to the 758933, 758917, or 701901
Length: 0.3m
Applicable for DL750/DL750P, SL1000, SL1400

701948 Extension Clip Accessories

Connected to the 700929, 701947
Maximum input voltage: 1,000V (DC + ACpeak)
Length: 0.26m/0.3m/0.4m
Applicable for DL750/DL750P, SL1000, SL1400

701954 Large Alligator Clip (dolphin type)

Set contains one black and one red clip.
1000 Vrms-CAT II.

720930 Clamp on Probe

The 720930 and 720931 passive clamp-on current probes allow current waveform readings directly via analog input modules on ScopeCorders including the DL350 and DL850 using isolated BNC connections.

  • AC 50 A
  • 40 Hz to 3.5 kHz Bandwidth

758929 Large Alligator Clip Adapter 1000V

  • Yokogawa 758929 Alligator Clip Adapter 
  • Rated at 1000V
  • Attaches to 758917 test leads
  • Sold in pairs black/red

758922 Small Alligator-Clip Adapter 300V

Rated at 300 V. Attaches to the 758917 test leads. Sold in pairs.

720931 Clamp on Probe

The 720931 passive clamp-on current probe anables current waveform readings directly via analog input modules on ScopeCorders including the DL350 and DL850 using isolated BNC connections.

  • AC 200 A
  • 40 Hz to 3.5 kHz Bandwidth

758921 Fork terminal adapter

  • 758921 Fork Terminal Adapters
  • For fitting a 4mm banana plug to a fork terminal
  • One black and one red clip
  • 1000 Vrms-CAT II

758923 Spring Hold Safety Terminal Adapter Set

Two adapters in a set (spring-hold type).

758931 Screw-Fastened Safety Voltage Terminal Adapter Set

Screw-fastened adapters. Two adapters in a set. 1.5 mm Allen Wrench.

701902/701903 Safety BNC to BNC Cable 1m/2m

  • 701902/701903 Safety BNC to BNC Cable for oscilloscope
  • Safe, high-voltage measurements with DL350, DL950, and SL1000 isolated input modules 
  • 701902: 1000 Vtms-CAT II (BNC-BNC), 1 m
  • 701903: 1000 Vrms-CAT II (BNC-BNC), 2 m

366924 BNC to BNC 1m Cable

  • 366924 BNC to BNC cable for oscilloscope 
  • 1m BNC wire
  • Simultaneous measurement with 2 units
  • Input external trigger signal

366925 BNC to BNC 2m Cable

BNC-BNC 2m. For connection to simultaneously measurement with 2 units, or for input external trigger signal.

366926 BNC to Alligator 1m Cable, 1:1

  • 1 m long BNC to alligator clip cable
  • Only for circuits with voltage levels no greater than 42 V
  • Applicable for DL750/DL750P, SL1000 & SL1400

366961 Banana to Alligator 1.2m Cable, 1:1

A subassembly of 1.2 m long test leads with alligator-clip adapters.
Use only for circuits having voltage levels no greater than 42 V.
Applicable for SL1000 & SL1400.

701919 Probe Stand

  • 701919 oscilloscope probe stand
  • Flexible arm, heavy base to hold and stabilize 8-13mm probes
  • Can simplify circuit board testing

B8059GG Soft case

Soft Case for Accessories

751541-E4 Rack mount kit

For SL1000 (EIA)

751541-J4 Rack mount kit

For SL1000 (JIS)

701904 1 to 1 Safety Adapter Lead

1:1 Safety Adapter Lead for the 720268 High Voltage Input Module

758928 Pinchers tip (Hook type)

1000 Vrms CAT III, 1 set each of red and black

Overview:

Observation of Inverter Switching Waveforms

Overview:

There are several factors for a user to consider when using an IEPE accelerometer, particularly when used with newly available integrated signal conditioner/data acquisition process. Correctly managing these factors will help the user avoid erroneous data from their IEPE accelerometer and ensure the quality of the data measurement is at the level they expect and require.

Industries:
Overview:

Surge Waveform Recording & Power Monitoring

Overview:

Xviewer may only be used to view and analyze data saved by the SL1000, it cannot be used to remotely control the SL1000. You can also transfer files between the SL1000 and a PC. For the SL1000, Xviewer can support ...

Overview:
  • Update Firmware on SL1000 High Channel Count ScopeCorder modular data acquisition system
  • Follow instruction procedures
Overview:
  • "Beat Method" for Inspecting an Oscilloscope’s Time Base Accuracy
  • Inspect and verify time base accuracy
  • Aliasing effect to create a "beat waveform." 
  • Time base setting formula
Overview:
  • Xviewer can open multiple files from different DL, SL, and WE series instruments into a single window display 
  • Same sample rate, trigger position, record length
Overview:
  • DC Precision when changing the DC waveform position setting on DL1600
  • How to calculate DC offset voltage
Overview:

Even though the correct USB drivers have been installed, and the device displays correctly in the Windows Device Manager Window, the High-Speed Data Acquisition Unit SL1000 Acquisition Software fails to detect the SL1000 main unit. Solutions: Verify ...

Overview:

Yes, you can use the 700929 isolated probe with non-isolated input modules.

Overview:

The SL1000 High-Speed Data Acquisition Unit is capable of linking up to 8 units, up to 128ch max, in synchronized mode using our SL1000 Acquisition Software. Using a common LINK file, data from all units can be processed and analyzed, as one, at the ...

Overview:

One possible solution is to use a third party 10:1 attenuator such as the one shown in the attached document. You may use the attenuator to allow the direct input of higher voltage levels with the 701262 module, since ...

Overview:

The AC Power Input in all Yokogawa instruments is designed as a 3-pin connection (one of which is a GND pin). In some parts of the world, PCs are sold with AC power cables that are 2-pin. Often times this means the ...

Overview:

The SL1000 High-Speed Data Acquisition Unit Portable Parallel Analyzer (PPA) doesn’t support offset summing like DLM2000 Mixed Signal Oscilloscopes.  The SL1000 doesn't have offset hardware; instead, the vOffset variable is used to affect the displayed value only.  So, using this parameter would have no ...

Overview:

High Resolution mode can be used to remove high frequency noise and increase vertical resolution. It achieves this by increasing the number of effective bits per data to 12-bits through digital and bandwidth filters.

Overview:
Unfortunately we do not have any experience using the SL1000 Acquisition Software on a PC that has Symantec Endpoint Encryption Software (SEES) installed.   SEES is a storage encryption software that provides data ...
Overview:
  • Correct AC coupling test for the 720210 Analog Voltage input module must be performed at 20 Hz
  • Service manual SMDL850-01EN_010 1st Ed suggests performing AC COUPLING test at 15 Hz 
  • This is a typo 
Overview:

The sanitation procedure for various Yokogawa oscilloscopes have been documented below. Please download the document or pdf that refers to your Yokogawa oscilloscope.

Overview:

No, the SL1000 and 720210 Modules service manual does not include any adjustment procedures however, it does contain the inspection procedure (QIS). 

Overview:

To perform a shunt calibration using the 701271 strain gage module and the ScopeCorder, please complete the following procedures: Connect the strain module 701271, bridge head 701957/701958 and the strain ...

Overview:

The SL1000 High-Speed Data Acquisition Unit has the following types of memory: Internal Hard Drive: 40 GB Non-Volatile SRAM Waveform Acquisition Memory: 128 MW or 256 MB Volatile RAM Setup File Data Storage: 1 MB Volatile SRAM(Battery-Backup)

Overview:

The maximum total file size you can record continuously depends on your sample rate, channel count and storage capacity. Please see the attached PDF file for an example of recording settings.Note: The dead-time between ...

Overview:

The SL1000 is capable of transferring previous data sets/files while streaming is still in progress through the File Divide feature. When the SL1000 starts recording, it opens a new file and starts logging data. If the ...

Overview:

Yes, VXI-11 is required and needs to be enabled for the DLM2000 Mixed Signal Oscilloscope to connect properly to Xviewer when using an ethernet connection. If the VXI-11 option is unchecked, a connection failed message will appear.   Related ...

Overview:

There are some modules that can be used with the DL750 Scopecorder but cannot be used with the DL850 Scopecorder. This is due to the nature of the FPGA for that module, which cannot be interchanged between the DL750 Scopecorder and the DL850 Scopecorder. During ...

Overview:

Depending on the mode, the dead time may range from 0 to 10ms approximately. The dead time for the different modes are listed below. Free Run Mode: 0ms Normal Mode without HDD recording: 10ms Normal Mode with HDD ...

Overview:

This training module covers the following topics:

  • Introduction & Installation 
  • Basics of Xviewer
  • Advanced features
  • Video Demonstrations 
Brochures
Instruction Manuals
Specifications
Software
Drawings

Looking for more information on our people, technology and solutions?


Contact Us

Precision Making

Top