CPU
300MHz or higher
1GHz or higher (Vista 7)
OS
Windows XP / Vista (32bit) / 7 (32bit/64bit)
Serial I/O capability
A serial port conforming to RS-232C standard should be available
Software
Microsoft Excel 2003 SP3
Microsoft Excel 2007 SP1(*1)
Microsoft Excel 2010
*Windows and Excel are registered trademarks of Microsoft Corporation.
*1: In Excel 2007 (Non SP), when you create a chart from a dataset, the axis may not work correctly. In Excel 2007 (SP2), when you create a line chart from a dataset that contains a large amount of data points, performance becomes slow.
Date | Version | Contents |
---|---|---|
Sep, 2011 | 2.10b | Ver. 2.10b supports Windows 7 and Excel 2010 |
Dec, 2010 | 2.10a | Trouble in which installation fails with OS other than English was corrected. |
Oct, 2009 | 2.10 | Ver2.10 supports Windows Vista and Excel2007 |
Please read Software Agreement carefully before downloading.
Downloading of the software indicates acceptance of the software agreement.
The CW240 is a portable three-phase power analyzer for field testing, maintenance, and service of equipment such as transformers, motors, and electrical distribution systems. It is a complete tool for measuring power quality, enhancing energy efficiency, assessing and improving equipment life cycles.
Compact & lightweight body with large back-lit LCD
Current clamps in a range of sizes(small to large diameter)
Support for large-capacity ATA flash memory (equipped with PC card slot)
Data can be saved at from 1 second
Wiring error check function
2 or 3-load system
Simultaneous measurement of multiple use possible by external control terminal
Parameters setting tool is included to set measurement conditions through PC