| Description | True RMS ACA, DCA, ACV, DCV | 
|---|---|
| Method of detection | True RMS | 
| Display | LCD (Digital display: 3999 counts) | 
| DC Current Range | 400/2000A | 
| DC Current Resolution | 0.1A | 
| Response Time | Approx. 1 second (on DC current/voltage range) Approx. 2 seconds (AC current/voltage range, resistance range) | 
| Range Switching | Auto-range | 
| Operating temperature and humidity | 0 - 40°C, 85% RH or less (no condensation) | 
| Influence of external magnetic field | 4A or less at 400 A/m | 
| Influence of conductor position | ±(1.5% rdg + 3 dgt) or less | 
| Safety Standard | Conforms EN61010-1, EN61010-2-031, EN61010-2-032 | 
| Circuit voltage | 1000 Vrms or less | 
| Withstanding voltage | 5.55 kV AC for one minute | 
| Power Supply | 6F22 (006P) 9V x 1 6LR61 x 1 | 
| Battery Life | Approx. 15 hours (continuous) | 
| Consumed current | Approx. 15 mA | 
| Sleep Function | Automatically powered down in about 10 minutes after the last switch operation | 
| Diameter of measurable conductor | 55 mm at maximum | 
| Dimensions | Approx. 105 (W) x 250 (H) x 49 (D) mm | 
| Weight | Approx. 540 g | 
| Accessories | Batteries, carrying case (93034) Output plug (98012) Test Lead (98011) User's manual (IM CL250) | 
| Peak Hold | On current / Voltage range | 
| AC Current Range | 400/2000A | 
|---|---|
| AC Current Resolution | 0.1A | 
| AC Current Frequency characteristics | 30~1kHz | 
| AC Current Method of detection | True RMS | 
| AC Voltage Measurement | O | 
| DC Voltage Measurement | O | 
| Continuity Check Measurement | O | 
| Frequency Measurement | O | 
| Temperature Measurement | - | 
| Recorder output Function | O | 
| Waveform monitor output Function | - | 
| Data hold Function | O | 
| Auto hold Function | - | 
| Peak Hold Function | O | 
| Maximum value memory Function | - | 
| Mean value display Function | O | 
| Filter Function | - | 
| Range Hold Function | - | 
| Auto ZERO Adjust Function | O | 
| Auto power-off Function | Δ | 
At 23°C±5°C,75%RH or less
Accuracy: ±( % rdg + dgt) = ±(% readout + value of least significant digit)
| Parameter | Reference | Accuracy | 
|---|---|---|
| DC current | 400/2000A | 1.5+2 | 
| AC current | 400A/2000A (150~1700A) | 1.5+3 (50/60Hz) | 
| 3.0+4 (30~1kHz) | ||
| 2000A (1701~2000A) | 1.0+2 | |
| DC voltage | 40/400/1000V | 3.5+3 (50/60Hz) | 
| AC voltage | 40/400/750V | 1.0+2 | 
| 1.5+3 (50/60Hz) | ||
| 2.0+4 (30~1kHz) | ||
| Crest factor | ≦3 | |
| Resistance | 400/4000Ω | 1.5+2 , Beeps at below 20Ω (continuity check) | 
| Frequency | 10~3999Hz | 1.5+5 | 
| DC output | DC400A (0~400mV) | ±1.5% rdg ±3mV | 
| DC2000A (15~200mV) | ±1.5% rdg ±3mV | |
| AC400A (0~400mV) /AC2000A (15~170mV/150~1700A) | ±1.5% rdg ±3mV (50/60Hz) | |
| ±3.0% rdg ±3mV (40~1kHz) | ||
| AC2000A (170.1~200mV/1701~2000A) | ±3.5% rdg ±3mV (50/60Hz) |