700924 100 MHz Differenztastkopf (EINGESTELLT)

Hinweis: Dieses Produkt wurde eingestellt 18.01.2021. See this replacement product:

Der Differenztastkopf 700924 bietet eine Bandbreite von 100MHz und eine Dämpfung von 100:1 oder 1000:1.

Applicable for DL750/DL750P & SL1400

With increases in the speed of measured signals in recent years, it has become necessary to make floating measurements over a wide frequency band. The 700924 differential probe lets you make wide-band (100 MHz) differential input measurements by just connecting the probe to the input of a single-end input digital oscilloscope.


Oscilloscope input amplifiers are normally single-ended. They do not provide accurate measurements when used in combination with a 10:1 passive probe for measuring the gate-to-source voltage of a switching power supply, or potential difference with a common mode voltage in elements such as Insulated Gate Bipolar Transistors (IGBTs).

Furthermore, there is a risk that current will enter through the oscilloscope ground line and damage the oscilloscope.

 


Tm 700924 02 1

Tm 700924 03 1
 

 

 

  Specifications
Input type Balanced differential input
Frequency band DC up to 100 MHz (-3 dB)
Input attenuation ratio Switched between 1/100 and 1/1000
Input impedance Approximately 4 MΩ, approximately 10 pF parallel
Gain accuracy ±2% (common mode voltage: 400 V or less)
±3% (common mode voltage: 1000 V or less)
Maximum allowed
differential voltage
±350 V (DC + ACpeak) or 250 Vrms (1/100 range)
±1400 V (DC + ACpeak) or 1000 Vrms (1/1000 range)
Maximum common mode
input voltage
±1400 V (DC + ACpeak) or 1000 Vrms
(both 1/100 and 1/1000 ranges)
Maximum input voltage ±1400 V (DC + ACpeak) or 1000 Vrms (1/1000 range)
Common Mode Rejection
Ratio (CMRR)
-80 dB (60 Hz), -50 dB (1 MHz)
Output voltage ±3.5 V
Output impedance Used with 1 MΩ input impedance
Power supplies Dry cells, four R6P (SUM-3);
when using the AC/DC adapter, use an output voltage
of 6 V/200 mA or greater/center plus
Dry cell life Approximately 2 hours under continuous use
External dimensions
(approximate)
207 mm x 83 mm x 38 mm¹
Total length Approximately 1.5 meters
Weight Approximately 800 grams (excluding dry cells)
Approved standards EMC: EN55011: 1991 + A1: 1997 + A2: 1996
EN50082-1: 1992
Safety: EN61010-1: 1993 + A2: 1995
EN61010-2-031: 1994

¹: 38 mm is listed as the maximum value.
Note: Dry cells and AC/DC adapter not included.

 

 

 

Model and Code

 

 

Model Name Code Description
Differential probe 700924 DC to 100 MHz band

Each 700924 differential probe comes standard with red and black pincher tips (one each).