IS8000 Integrated Software Platform

The IS8000 Integrated Software Platform streamlines the process of integrating, synchronizing, and measuring data. Add-on software packages give this test and measurement software evolving capabilities.

*The firmware update is required for each devices to connect IS8000.
DL950:Ver.1.50 or later, WT5000 : Ver. 3.61 (upcoming) or later

Ver.24.1.2.0

  • Added harmonic and interharmonic measurement for IEEE 1547-2018 and VDE-AR-N 4105 Standard, as the standard features of IS8001/IS8002.
    (G7 option and upcoming firmware ver.3.61 on the connecting WT5000 is required.)
    (Not available on the IS8011/IS8012.)
  • Expanded API features that enable configurations of DAQ condition, recording channels, saving folders, and others.
  • Improved operability of the zoom function.
  • Added new keypad for DL950 remote control function.

Ver.24.1.1.0

Ver.23.4.1.0

  • Added support for DL950/MT1: Motor dq Analysis option.
  • Added the Numeric Monitor display for DL950 and RAMScope.
    (EM1 option required to connect RAMScope series.)
  • Enabled preview of Peak-to-Peak compressed waveform from WT5000.
  • Enabeld simultaneous recording of Data-Streamed waveform and Peak-to-Peak compressed waveform from WT5000.
    (DS option is required on the connected WT5000.)
  • Serial Bus Analysis function: Enabled search by data information and exporting the decoded data as CSV file.
    (SB1 option required)
  • Improved performance for waveform display.

Ver.23.3.1.0

  • Added support for the DLM5000HD Series High Definition Oscilloscopes.
  • Improved time taken to launch the software and display the waveforms.
  • Enabled to create a cache file to load MDF files faster. The feature can be turned on from the settings menu.
  • Added the Peak-to-Peak compression (extracting the maximum and minimum values for each interval) to the compression process for file exporting.
  • Enabled to change the number of significant digits displayed for cursor and statistical values.
  • Enabled to display the DC component of the FFT waveforms (with MH1 option).

Ver.23.2.1.0

  • Added support for new options, Serial bus analysis (SB1) and Modbus/TCP communication (MB1).
  • New harmonics acquisition mode compliant with IEC 61000-4-7 Annex B (2k-9kHz) is supported in IS8001/IS8002.
    (G7 option is required on the connected WT5000.)

IEC61000-4-7

IEC61000-4-7_2

  • Math option (MH1): By installing MATLAB Runtime, up to 100M of computed points can be supported
  • New IEC61000 standard (3-12 Ed2.0-amd1) is supported in IS8011/IS8012

Ver. 23.1.1.0

  • New IEC61000 standard (3-3 Ed3.0-amd2) is supported in IS8011/IS8012.
  • "DAQ(WT)", which displays a layout suitable for online DAQ of WT5000, is added to the launcher window.

Ver. 23.1.1.0_1

 

Ver. 23.1.1.0_2

Ver. 22.6.1.0

  • Added new API function: any waveform file access
  • Improved the performance of analysis functions
  • Enabled importing CSV files saved with DL950, DL850 series, DL350, DLM5000/4000/3000/2000 series, Xviewer Application Software and IS8000 (version 22.6.1.0 or later)
  • Enabled importing/exporting CSZ format (CSV data compressed in ZIP format)

Ver. 22.5.1.0

  • Added new API functions
  • Improved the performance of analysis functions
  • Enabled CSV exports of dual-caputured sub-channel data, FFT analysis data, and sequential historical data
  • Added support for a vector diagram display for off-line analysis functions

IS8000 Integrated Software Platform | Yokogawa Test&Measurement

  • Added support for the latest IEC standard, IEC61000 3-2 Ed5.0-amd1, with IS8011/IS8012
  • Added support for Windows11 with IS8011/IS8012
    (All IS8000 series functions except EM1 option are Windows 11 compliant)
  • FS1 option: The information on camera models that support real-time synchronization has been changed
  • MATLAB Runtime support: By installing MATLAB Runtime, up to 100M of FFT points can be supported

 

Ver. 22.4.1.0

  • Added support for Windows11 (except IS8011 and IS8012)
  • Added a new API function
  • Improved the performance of analysis functions
  • Added support for the DAQ (data acquisition) function from DL950 with an external clock
  • Added support for a vector diagram display for WT5000’s online monitoring and DAQ function (supporting one for offline analysis functions will be available in a future update)
  • Removed the limitations of the maximum DAQ period which were seven days and 500 GB
  • Added support for the offline synchronization function with two video files and waveforms (FS1 option required)
  • Added support selecting “seconds” and “points” for the time axis information of saved data in the CSV export function

 

Ver. 22.3.1.0

  • Added the new API functions (IS8000 control API)
  • Improved performance for offline analysis

 

Ver. 22.2.2.0

  • Supported the IS8000 API (Application Programming Interface)

 

Ver. 22.2.1.0

  • Supported WT5000 data streaming (/DS) function *1
    This function streams the waveform data measured by the WT5000 continuously to the PC.
    In addition, the measured waveform can be saved as an MDF/CSV file, analyzed for feature points, calculated, and FFT processed *2.
    More detailed analysis is possible, such as how a change in the noise or control state affect the power value and each parameter.

*1 DS option is required on the connected WT5000.
*2 MH1 option on the IS8000 is required for some calculations and analysis

Software Update Information

  • Added the customization of the default window layout
    The initial window layout can be customized freely. This is useful when you want to fix the display layout.
  • Increased the number of harmonic bar graphs displayed from two to six.

 

Ver. 22.1

  • Video File Offline Synchronization (/FS1 option)
    It is possible to display video data other than supported high-speed cameras by offline analysis.
    *Supported file format
    AVI(*.avi)、MP4(*.mp4)、WMV(*.wmv)
    AVCHD(*.mts)、MOV(*.mov)、MPEG2-PS(*.mpg, *.mpeg)
  • Screen Capture function added
    The function which save IS8000 display added. It is possible to narrow down the target such as Zoom waveform and save it.
  • Supports mouse wheel operation for waveform display
    It is possible to operate such as moving the vertical scroll bar with the mouse wheel.
  • Added CSV file batch converter function
    It is possible to convert multiple waveform files to CSV at once.
  • Added Probe setting
    The attenuation ratio of the probe that can be set has increased.
  • The result of power calculation (/ G5) is added to the target of DL950 Flash ACQ data saving.
    Supports MDF file saving of DL950 power calculation result in Flash ACQ data saving.

 

Ver. 1.4

  • Added Channel Mapping Function
    Channel Mapping function was added to “Channel Setting”.
    This function allows you to change the display channel assignments.

Introduction of Added Functions

  • Supported the Real-time Power Math Function of DL950
    The online data acquisition of results for the real-time power math computation of DL950 (/G05) is supported on latest IS8000.
  • Updated CSV file export function
    Exporting multiple waveform data with different sampling interval to a single CSV file has been supported. It also supported CSV file exporting function of numeric, matrix and harmonic bar graph data.
  • Added Apply button to channel setting window of offline analysis
    The channel setting changes can be reflected in the waveform window without closing the channel setting window.

 

Ver. 1.3

  • Supported DL950 Flash acquisition function (/ST2)
    Acquisition data of DL950 flash acquisition function can be imported to IS8000.

Flash acquisition function

  • Supported WT5000 10ms update rate
    Update rate of WT5000 can be set to 10ms when connecting IS8000.
  • Supported matrix display of WT5000 numeric data
    Latest IS8000 can display the matrix of WT5000 numeric data in offline analysis.
  • Supported WVF file
    Supports reading WVF file created by DL750 or SL1400.
    (The HDR file with the same name as the WVF file is required.)
  • Added CSV export function on the simple version
    It is possible to export measurement data to CSV file on the simple version.
Version Date Description
V24.1.2.0 Apr 11, 2024 Added harmonic and interharmonic measurement for IEEE 1547-2018 and VDE-AR-N 4105 Standard, as the standard features of IS8001/IS8002.
(G7 option and upcoming firmware ver.3.61 on the connecting WT5000 are required.)
(Not available on the IS8011/IS8012.)
Improved operability of the zoom function.
Added new keypad for the DL950 remote control function.
V23.4.1.0 Nov 17, 2023 Added support for DL950/MT1: Motor dq Analysis option.
Added the Numeric Monitor display for DL950 and RAMScope.
Enabled preview of Peak-to-Peak compressed waveform from WT5000.
Enabled simultaneous recording of Data-Streamed waveform and Peak-to-Peak compressed waveform from WT5000.
Serial Bus Analysis function: Enabled search by data information and exporting the decoded data as CSV file.
Improved performance for waveform display.
V23.3.1.0 Sep 15, 2023 Added support for the DLM5000HD Series High-Definition Oscilloscopes
Improved time taken to launch the software and display the waveforms.
Enabled to create a cache file to load MDF files faster. The feature can be turned on from the settings menu.
Added the Peak-to-Peak compression (extracting the maximum and minimum values for each interval) to the compression process for file exporting.
Enabled to change the number of significant digits displayed for cursor and statistical values.
Enabled to display the DC component of the FFT waveforms (with MH1 option).

Previous version 

New options

Serial Bus Analysis(SB1)

This is an analysis function for CAN bus communication widely used in in-vehicle networks and other applications. It enables decoding of communication contents, frame display, and search for specific information in CAN bus communication signal. This new serial bus analysis option can also be used to analyze signal waveforms acquired not only by Yokogawa's oscilloscopes but also by the ScopeCorder series and IS8000. It is effective for reanalysis of communication signal waveforms previously measured, and for comparison and analysis with other physical quantity measurements.

Serial Bus Analysis(SB1)

Modbus/TCP Communication(MB1)

Modbus/TCP communication. A communication configuration file for connection to the YOKOGAWA GM10 and VZ20X recorders is included with the software. Other Modbus/TCP communication devices can also be connected to the IS8000 by creating a communication configuration file using the included tool. Integration of these devices with a Yokogawa Test & Measurement’s power analyzer and waveform measuring instrument by the IS8000 will provide a measurement system that supports more input channels, longer recording times and a wider variety of temperature sensors.

Screenshot example of data acquisition with Yokogawa's GM10 and DL950

Screenshot example of data acquisition with DL950 Yokogawa's GM10

Modbus configuration file editor

Modbus communication configuration file editor

The Power of One

The IS8000 software platform is an integrated solution that accelerates engineering workflow. It is a revolutionary software solution that tightly integrates the timing, control, and data collection from multiple instruments, creating a comprehensive measurement suite that delivers high confidence, efficiency, and unity.

IS8000 Integrated Software Platform | Yokogawa Test&Measurement

High speed data acquisition up to 10 Gb

In combination with the 10 GbE option (C60 option) on the DL950 and the IS8000, up to 8 channels of data can be stored in real time on a PC at a sampling rate of up to 20 M samples per seconds.*

Longer recording times are now possible for high-speed, multi-channel inputs such as gate signals and switching waveforms of multi-phase inverters.

* With 1 Gb Ethernet/USB connection, the maximum transfer rate is 6.4 MB/s (200 kS/s × 16 ch) 
IS8000 Integrated Software High Speed Data Acquisition | Yokogawa Test&Measurement
 

Multi-unit monitoring with time synchronization (SY1 option)

IS8000 and SY1 option enable accurate power and waveform data synchronization across multiple channels with minimal error. Data from the WT5000 power analyzer and DL950 ScopeCorder is time correlated with less than 10 us error using IEEE1588 technology.

IS8000 Integrated Software Multi Unit Monitoring Time Synchronization | Yokogawa Test&Measurement
 

Control and realtime remote monitoring

YOKOGAWA’s high-precision power analyzer, ScopeCorder and oscilloscope can be remotely operated, monitored and configured from IS8000. Additional options, third-party high-speed cameras can also be controlled, greatly reducing the burden of operating and managing various instruments measuring power, physical phenomenon, video, and control signals.

IS8000 Integrated Software Control Realtime Remote Monitoring | Yokogawa Test&Measurement
 

FFT and math function (MH1 option)

Measure up to 16 FFT processes for a wealth of analysis functions for automatic calculation of frequency and integrated value and filter processing.

IS8000 Integrated Software FFT and Math Function | Yokogawa Test&Measurement
 

Report generator (RP1 option)

Customized reports are easily created by dragging and dropping measurement data, waveforms, graphs, etc. onto the sheet.

IS8000 Integrated Software Report Generator | Yokogawa Test&Measurement
 

File import and export

The IS8000 supports binary, ASCII, and the MDF format, a very common format for the automotive industry. Power and waveform data on the IS8000 can be shared with your development system or third-party software.

IS8000 Integrated Software Platform MDF ASCII Data Export | Yokogawa Test&Measurement

*1 Import of MDF files generated by other software/devices will be supported in the future
*2 Power trend data saved by WT5000, WT3000, 1800 series

Synchronization high-speed camera (FS1 option)

IS8000 synchronizes high speed camera images with related current, voltage, and control signals. Simultaneous slow motion playback allows visualization between design and results.
In addition, video files captured by other than high-speed camera and waveform files can be synchronized offline for display and analysis.

IS8000 Integrated Software Synchronization High Speed Camera | Yokogawa Test&Measurement
 

IEEE1588 Precision Time Protocol

IEEE 1588 is a standard for the Precision Time Protocol (PTP), a protocol for high-precision time synchronization of networked instruments and control systems. The PTP grandmaster server provides a reference clock for each client instrument to achieve high-precision clock synchronization. Since the ScopeCorder DL950 has the PTP master function, high precision clock synchronization of the corresponding instruments on the same network is possible even without a PTP grandmaster server. The IS8000 is also capable of combining the simultaneous measurement data of each of these PTP-synchronized instruments in the same window.

IS8000 Integrated Software Platform IEEE1588 Precision Time Protocol | Yokogawa Test&Measurement

Optional software package for IEC harmonic and flicker compliance test

IS8011/IS8012 optional software package is designed to perform harmonic and flicker tests in accordance with IEC61000-3-2, 3-3, 3-11 and 3-12 standards using the WT5000 precision power analyzer. Users can easily set the conditions and output the test report without any specialized knowledge. Users can make a pass/fail judgment by class A, B, C, and D of the harmonic current measurement values.

IS8000 Integrated Software IS8011 IS8012 IEC Harmonic Flicker Compliance Analysis | Yokogawa Test&Measurement

Compatible measurement device:
WT5000 (/G7 option required)

Applicable standards:
IEC 61000-3-2 Harmonic Measurement

  • IEC 61000-3-2 Edition 3.0:2005/A1:2008/A2:2009, IEC 61000-3-2 Edition 4.0:2014, IEC 61000-3-2 Edition 5.0:2018/A1:2020
  • EN 61000-3-2:2006/A1:2009/A2:2009, EN 61000-3-2:2014, EN 61000-3-2:2019, EN 61000-3-2:2021
  • IEC 61000-4-7 Edition 1.0:1991, Edition 2.0:2002 and A1 of the Edition 2.0:2008
  • EN 61000-4-7:1993, EN 61000-4-7:2002/A1:2009
  • JIS C 61000-3-2:2011, JIS C 61000-3-2:2019
  • JIS C 61000-4-7:2007

IEC 61000-3-3 Voltage Fluctuation and Flicker Measurement

Voltage fluctuation and flicker suppression standards

  • IEC 61000-3-3 Edition 2.0:2008, IEC 61000-3-3 Edition 3.0:2013/A1:2017/A2:2021
  • EN 61000-3-3:2008, EN 61000-3-3:2013, EN 61000-3-3:2013/A1:2019, EN 61000-3-3:2013/A2:2021

Flicker meter function and design specifications

  • IEC 61000-4-15 Edition 1.1:2003, IEC 61000-4-15 Edition 2.0:2010
  • EN 61000-4-15:1998/A1:2003, EN 61000-4-15:2011

IEC 61000-3-11 Voltage Fluctuation and Flicker Measurement

Voltage fluctuation and flicker suppression standards

  • IEC 61000-3-11 Edition 1.0:2000, IEC 61000-3-11 Edition 2.0:2017
  • EN 61000-3-11:2000, EN 61000-3-11:2019

Flicker meter function and design specifications

  • IEC 61000-4-15 Edition 1.1:2003, IEC 61000-4-15 Edition 2.0:2010
  • EN 61000-4-15:1998/A1:2003, EN 61000-4-15:2011

IEC 61000-3-12 Harmonic Measurement

  • IEC 61000-3-12 Edition 1.0:2004, and Edition 2.0:2011/A1:2021
  • EN 61000-3-12:2005, EN 61000-3-12:2011
  • IEC 61000-4-7 Edition 2.0:2002/A1:2008
  • EN 61000-4-7:1993, EN 61000-4-7:2002/A1:2009

Supported devices

Functions Supported devices
Online data acquisition DL950, WT5000
Remote control and setting, acquisition data download DL350, DL850 series, DL950, DLM3000 series, DLM5000 series, DLM5000HD series, WT5000 (Remote control and setting only)
Data File Import DL350, DL850 series, DL950, DL750 (Only WVF file), SL1400 (Only WVF file) , SL1000, WT1800 series, WT3000 series, WT5000, DLM2000 series, DLM3000 series, DLM4000 series, DLM5000 series, DLM5000HD series
High-speed camera Sync.
(FS1 option)
Supported cameras for online sync.: Photron’s FASTCAM SA-Z, MIni UX*/AX/WX series, NOVA S series, NOVA R2
Supported devices for online sync.: DL950
Modbus/TCP Communication
(MB1 option)
Devices supported Modbus/TCP protocol.
ECU Monitor sync.
(EM1 option)
DTS INSIGHT's RAMScope GT170(only for the variable data acquisition and calibration module), GT122

* Pre-trigger recording and multi-trigger recording using the Mini UX series in combination with the FS1 option are not supported.

 

Main specifications

The writings in red are changes from the previous version.

  Ver. 24.1.2.0
Connecting support firmware DL950 Ver.1.50 or later
WT5000 Ver. 3.61 (upcoming) or later
Languages English / Chinese / Japanese
PC requirements For data acquisition with 10 Gb Ethernet connection;
CPU: Desktop PC required
Intel Core i7-1165G7 or later Intel CPU
4 cores(8 threads) or more 4.7 GHz or faster
Amount of memory: 16 GB or more
Amount of SSD: 512 GB or more
(M.2 slot is recommended, Sequential read/write 3 GB/s or faster)

For data acquisition with 1 Gb Ethernet
/USB connection and offline analysis;
CPU: Intel Core i5-10210U or later Intel CPU
4 cores(8 threads) or more 4.2 GHz or faster
Amount of memory: 8 GB or more
Amount of SSD: 256 GB or more
(Sequential read/write 400 MB/s or faster)
OS Windows 11 Pro or Enterprise edition (except EM1 option)
Windows 10 64bit Pro or Enterprise edition
Communication interface USB (USBTMC / VISA), Ethernet (VXI-11, HiSLIP, Modbus/TCP *8)
Display resolution 1366×768 dots or higher, 100 % zoom
Number of connectable units (SY1 option) Up to 5 units
(Only one unit without SY1 option)
(SY1 option is required even if the time synchronisation is not used)
Supported file format WDF DL350, DL850 series, DL950, SL1000, DLM2000 series, DLM3000 series, DLM4000 series, DLM5000 series,DLM5000HD series
CSV (Waveform data) DL950, DL850 series, DL350, DLM5000HD/5000/4000/3000/2000 series, Xviewer Application Software and IS8000 *6
CSZ IS8000 CSV data compressed in ZIP format
CSV (Power measurement data)*2 WT5000
(without multi-unit sync. based on IEEE1588 PTP)
WT5000
(with multi-unit sync. based on IEEE1588 PTP.)
WT3000 series*1
WT1800 series
WVF DL750, SL1400
MD4 IS8000 data files
ASAM MDF 4.1 files
mepjt, anpjt IS8000 Project files
Export file formats ASAM MDF 4.1 files (mf4), ASCII files (csv), CSV files compressed in ZIP format (csz)
Online data acquisition
(DL950)*7
Motion mode Scope mode (Trigger/ Free-run)*4
The trigger mode cannot be used with multi-unit synchronized DL950s.
Maximum transfer rate 10G Ethernet connection: 320MB/s (20MS/s x 8ch, 10MS/s x 16ch)
1G Ethernet / USB connection: 6.4MB/s (200kS/s x 16ch)
Online data acquisition
(WT5000)*7
Monitoring/DAQ items Power trend graph and numeric
Harmonic bar graph *9
Data-streaming waveform *3
Vector diagram
Online data acquisition
(common)*7
Maximum continuous recording time/size The recording will be kept until free storage space falls below 10%.
Maximum recording channels 128 channel
Waveform overlays Aligned by time, absolute time ,head of data, end of data or arbitrary position
Automated waveform parameter measurements Up to 28 parameters (including P-P, Amp, RMS and Freq).
Display format Common TY-Overview (up to 32 ch for each group, up to 4 group), XY (up to 2 windows for each group), TY-View (up to 4 areas for each group), Numeric Monitor(Up to 128 channels)
For WT5000 Power trend graph and numeric display
Peak-to-peak compressed waveform (Data update interval: 1s or slower)
Bar graph of the amplitude and phase of each harmonic *9
Data streaming waveform display *3
Harmonic list display
Matrix display
Vector diagram
Automated waveform parameter measurements Automated measurement of history statistics Waveform parameters for each waveform in the historical memory and their statistics can be calculated automatically.
Automated measurement of cycle statistics Waveform parameters of each period of a cyclic waveform and their statistics can be calculated automatically.
Cursor Vertical, Horizontal, X-Y
Annotation function Comments, acquired data and calculated values can be added on the overview/view, waveform window and X-Y window.
Supported devices Data acquisition DL950
WT5000(760903 Current Sensor Element supported.10ms update rate supported.)
Flash ACQ data saving DL950
Data file import DL350, DL850 series, DL950, SL1000, WT1800 series, WT3000 series, WT5000, DLM2000 series, DLM3000 series, DLM4000 series, DLM5000 series,DLM5000HD series, DL750 (Only WVF files), SL1400 (Only WVF files)
Remote control and setting, acq. data download DL350, DL850 series, DL950, DLM3000 series, DLM5000 series,DLM5000HD series, WT5000(Remote control and setting only)
Screen Capture Save Clipboard, ping, jpg, gif
CSV batch converter Load MF4 (MDF4.1), WDF, WVF
Save CSV
Mathematical data analysis(/MH1) Number of Math channels Up to 16 channels
Operators +, -, x, /, Phase shift, ABS, SQRT, LOG, EXP, NEG, SIN, COS, TAN, ATAN, PH, DIF, DDF, INTEG, BIN, P2, P3, F1, F2, FV, PWHH, PWHL, PWLH, PWLL, PWXX, DUTYH, DUTYL, FLT1, FLT2, HLBT, MEAN
Number of computed points Up to 12.5 M points
or up to100 M points can be supported by installing MATLAB Runtime
Digital filters Gauss, Sharp, IIR(Butterworth)
FFT analysis (/MH1) Operator Type: LS, RS, PS, PSD, CS, TF, CH
Sub-type: REAL, IMAG, MAG, LOGMAG, PHASE
Window function Rect, Hanning, Flat top, Hamming
Number of FFT channels Up to 16 channels independently
Number of computed points Up to 2 M points
or up to100 M points can be supported by installing MATLAB Runtime
Serial bus analysis(/SB1) supported protocol CAN (CAN FD is not supported at present.)
Search target SOF, ID/Data, Error
Number of search points Up to 100,000 frames
Bit rate Select the value from 33.3kbps, 83.3kbps, 125kbps, 250kbps, 500kbps,1Mbps, or enter it within the range of 10kbps to 1Mbps in 0.1kbps steps.
High-speed camera Sync. (/FS1) Supported cameras for online sync Photron’s FASTCAM SA-Z, MIni UX*5/AX/WX series, NOVA S series, NOVA R2
Supported video format for online sync high-speed camera video files(avi)
Supported devices for online sync DL950
Supported video file formats for offline sync AVI(*.avi), MP4(*.mp4), WMV(*.wmv), AVCHD(*.mts), MOV(*.mov), MPEG2-PS(*.mpg, *.mpeg)
ECU Monitor sync.(EM1 option) Supported monitoring tools DTS INSIGHT's RAMScope GT170(only for the variable data acquisition and calibration module), GT122
Supported data file RAMScopeVP output files(a2l)
Supported devices for online sync DL950

*1 Harmonic measurement data excluded.
*2 The measurement data of first 128 channels can be imported.
*3 /DS option is required for the WT5000 to be connected.
*4 Trigger DAQ with DL950 external clock input is not supported.
   Freerun DAQ with DL950 external clock input, including 16-channel input module or CAN/CANFD/LIN/SENT module, is not supported.
*5 Pre-trigger recording and multi-trigger recording using the Mini UX series in combination with the FS1 option are not supported.
*6 Only CSV files saved with Ver. 22.6.1.0 or later IS8000 can be imported.
*7 Connecting instruments and collecting data with multiple launches of the IS8000 software on the same PC is not covered by the specification.
*8 MB1 option is required.
*9 G7 option on the connecting WT5000 is required to display measurement data complying with IEC 61000-4-7 Annex B (2k-9kHz).

 

Models and features

IS8000 Edition, License and Features

Models and features

 

DL950 ScopeCorder

DL950 ScopeCorder for IS8000 Software | Yokogawa Test&MeasurementThe DL950 combines a mixed signal oscilloscope and portable data acquisition recorder into a single platform which can capture both high speed transient events and long term trends and capable of high-speed, multi-channel measurements up to 200 MS/s and up to 16-bit A/D. With a combination of more than 20 different modules for your application, a single unit can measure isolated analog signals from low voltage to 1000 V, as well as logic signals, vibration and strain, temperature and more. It can also display automotive communication data such as CAN/CAN FD/LIN/ SENT as trend waveforms. The 12.1-inch large touch screen enables an intuitive operation. The newly designed application menu makes it easy to set up frequently-used applications. By combining the DL950 with the IS8000, data can be transmitted directly to a PC while measuring, allowing analysis on a PC. Up to five DL950 units can be synchronized with optical fiber cords to measure up to 160 channels simultaneously. Click here to learn more about the DL950 ScopeCorder.

WT5000 Precision Power Analyzer

WT5000 Power Analyzer for IS8000 Software | Yokogawa Test&MeasurementWT5000 precision power analyzer is a high-precision power meter with a basic power accuracy of ±0.03%, one of the best in the world. With a DC power accuracy of ±0.07%, a 10 MHz voltage measurement bandwidth, a 5 MHz current measurement bandwidth, and a low power factor characteristic of ±0.02% (of apparent power), the WT5000 provides highly accurate measurements of power consumption, loss, and conversion efficiency of devices. Up to seven power inputs and four motor torque inputs enables simultaneous evaluation of multiple motor drive systems. The WT5000 helps to improve the efficiency of development of EVs, EHVs, renewable energy related devices, and energy saving home appliances. Click here to learn more about the WT5000 Precision Power Analyzer.

DLM5000HD Series High-Definition Oscilloscope

DLM5000HD Series High-Definition Oscilloscope for IS8000 Software | Yokogawa Test&MeasurementThe DLM5000HD is a compact eight-channel 12-bit oscilloscope with the ability to observe and analyze complex high-speed waveforms in high resolution, making it easy to check fine noise, ringing, and other details. The intuitive touchscreen, auto setup, and extensive analysis functions accelerate complex diagnosis, providing unparalleled testing precision.Click here to learn more about the DLM5000HD Series High-Definition Oscilloscope.

 

Compatible Models

Standard Functions

IS8000 Integrated Software Compatible Models Standard Functions | Yokogawa Test&Measurement

*1 Only one unit
*2 Limited functions
*3 "DLM5000" includes DLM5000HD series.

Optional Functions

IS8000 Integrated Software Compatible Models Optional Functions | Yokogawa Test&Measurement

Compatible high-speed cameras for online synchronization:
Photron FASTCAM SA-Z、MIni UX*2/AX/WX series, NOVA S series, NOVA R2

*1 "DLM5000" includes DLM5000HD series.
*2 Pre-trigger recording and multi-trigger recording using the Mini UX series in combination with the FS1 option are not supported.

IS8000 Integrated Software Interface | Yokogawa Test&Measurement

IS8000 Integrated Software Intuitive User Interface | Yokogawa Test&Measurement

Automotive & Industrial

IS8000 Integrated Software Motor Efficiency | Yokogawa Test&MeasurementMotor Efficiency

Overview

Motor efficiency is a critical measurements for electric vehicles as small improvements can result in increased range. Efficiency measurements require accurate synchronous measurments of power consumption with motor speed and torque.

IS8000 Advantage

High Precision synchronized power and high speed recorder measurements
Data from the WT5000 power analyzer and DL950 ScopeCorder is time correlated with less than 10 us error using IEEE1588 PTP technology. Precise power parameters and waveforms are displayed on the same time axis.
 

IS8000 Integrated Software Switching Waveform Analysis Sic Invertor | Yokogawa Test&MeasurementSwitching Waveform Analysis for SiC Invertor

Overview

In order to analyze the motor and inverter system, voltage and current signals between 3 phases, motor I/O signals, and multiple IGBT gate signals are required to properly measure and diagnose system performance and efficiency.

IS8000 Advantage

Combining multiple waveforms
More than 8 waveforms are required to measure invertor performance in a loaded system. IS8000 can connect with multiple 8 channel DLM5000 oscilloscopes for analog and digital signals to scale up to any channel requirement, all in one control and viewing interface.
 

Power & Energy

IS8000 Integrated Software Solar Wind Power System Development | Yokogawa Test&MeasurementSolar/Wind Power System Development

Overview

Renewable energy systems, like wind, solar and hydro must maintain efficiencies through their power conversion stages to decrease their impact on the environment. Multiple measurement points require precsion and synchronization.

IS8000 Advantage

View and compare waveforms from multiple instruments
IS8000 can easily shnchronize waveforms from multiple instruments, creating an easy view for comparion. Manipulating waveforms is easily done with zoom and pan controls to analyze long records of energy waveforms.
 

Research & Development

IS8000 Integrated Software Analysis of Robotic Welding Control | Yokogawa Test&MeasurementAnalysis of Robotic Welding Control

Overview

It is necessary to optimize robotic welding conditions for a cost effective manufacturing system. Multiple signals and inputs are required to be monitored in order to determine the best combination between the robot’s position and performance, including high speed camera inputs, source voltage and current, and multiple position and control I/O signals.

IS8000 Advantage

Simultaneous recording of multiple signal types
IS8000 displays multiple inputs. The camera image is aligned in time with the other waveform, including the control signals and the voltage and current waveforms. Simultaneous slow motion playback allows visualization between design and results.

IS8000 Edition, License and Features

IS8000 Integrated Software Platform Licenses and Fees | Yokogawa Test&Measurement

Subscription License

This licenses type is based on annual subscription renewal for the platform and optional features. Users can purchase the software for as long as they need it, keeping their initial investment to a minimum. Users will always have the latest version of the software available for the duration of the subscription, so they will always be able to use the latest features, standards and security.

Perpetual License

This is a one-time purchase and can be used indefintely. Additional optional features can be purchased at a later date. The platform can be upgraded free of charge for up to five years major software version revisions after purchase. After that, users can continue to use the software in the same environment. This license is suitable for users who do not plan to change their equipment environment at the time of installation.

Activation 

All IS8000 models and licenses, except the free trial period, require software activation over the internet before use. If the PC with the IS8000 installed cannot be connected to the network, it is possible to activate the IS8000 via another network-accessible PC. For more information, please refer to the electronic manual.

Overview:

Detailed measurement methods, supply voltage settings, and others are specified for the harmonic/flicker standard test.

Overview:
  • IS8000 Integrated Software Platform
  • Measure current waveform using oscilloscope
T&M Hausmagazin
814 KB
Overview:

Reportage
Bitte aufsteigen!
Brompton Bicycle–Seite 4

Editorial
Alles beim Alten?–Seite 3

Interview
Anna Krone über Motoren, Mut
und Messtechnik–Seite 7

Neuheit
Vielseitigkeit bietet Vorsprung
Der neue ScopeCorder DL950–Seite 10

Mess- und Analyse-Software
Neue Softwareplattform IS8000–Seite 12

Product Overviews

    Product Overview
    Overview:

    The IS8000 Integrated Software Platform software platform is an integrated solution that accelerates engineering workflow. It is a revolutionary software that tightly integrates the timing, control, and data collection from multiple instruments, creating a comprehensive measurement suite that delivers confidence, efficiency, and unity.

    Overview:

    Test and measurement engineering work groups can have differing priorities and requirements, which often results in multiple instrumentation systems and data file formats, as well as incompatible reporting. This lack of effective communication between groups and instruments causes decreased efficiency and quality and increased spending and time to market. Unify test and measurement instrumentation, software, and data across engineering teams with a suite of solutions that caters to the different needs of engineering work groups, including accurate power data, fast sampling rates, long recordings of multiple different input types, and insights into waveform data.

How-tos

    Overview:

    Looking for a turnkey high-speed data transfer solution with better bandwidth and minimal manual overhead?

    The 10Gb Ethernet option on the Yokogawa Test&Measurement DL950 ScopeCorder fits that very role and makes capturing and recording high-speed data seamless and convenient.

    Record data at 50 times the speeds of traditional Ethernet and USB connections and automatically transfer data to your PC in a single step using the IS8000 Integrated Software Platform.

    Overview:

    The multi-unit synchronization option for the Yokogawa Test&Measurement DL950 ScopeCorder lets you time synchronize up to five DL950 ScopeCorders, for up to 160 channels of voltage, current, temperature, strain measurements, and more. This video walks you through how to set up and connect the multiple DL950 ScopeCorders, take measurements, and pull the data from all of the instruments for analysis with the IS8000 Integrated Test and Measurement Software Platform.

    Overview:

    Having multiple memory options allows engineering groups to optimize how data is stored, no matter if you need to record for a long time at slower sampling rates, do a fast capture at high sampling rates, or anything in between.

    The Yokogawa Test&Measurement DL950 ScopeCorder operates as an oscilloscope and incorporates the ability to record data for long periods of time like a data acquisition recorder. There are four memory types on the DL950 ScopeCorder: internal memory, solid state drive, flash memory, and PC storage through the IS8000 Integrated Test and Measurement Software Platform. This videos talks about the advantages of each of these and how to pick the best data recording method for you.

Webinars

    Overview:

    With ongoing innovations in motor and inverter technologies seeking to advance global decarbonization objectives in the automotive industry, it’s crucial that engineers have a thorough understanding of how to properly analyze these systems.

    This complimentary webinar provides engineering professionals involved in motor and control system development with insights that enable data benchmarking and troubleshooting issues related to energy efficiency in electric vehicle (EV) powertrains.

    Key webinar topics include:

    • Establishing baselines for system efficiency
    • Conducting inverter control signal analysis at the systems level
    • Identifying critical measurements for benchmarking inverter input, inverter output, and motor output
    • Analyzing motor control signals, including torque control variables, positional sensors, and pulse-width modulation (PWM), as well as torque measurements