761922 Harmonic Analysis Software for WT3000/WT3000E (Upgrade Version)
761922 Harmonic Analysis Software for WT3000/WT3000E (Upgrade Version)
Description
The 761922 harmonic/flicker measurement software allows you to load data measured by the WT3000/WT3000E onto a PC and perform harmonic measurements conforming to IEC61000-3-2 Ed5.0. The WT3000/WT3000E supports the 50/60 Hz (10/12 cycles) of interharmonic measurement required by IEC61000-4-7 Ed2.0 Am1, which may become a requirement for standards measurement in the future.
The measurement procedure required by the international standard for harmonic current suppression, IEC 61000-3-2 Ed. 3.0, has been amended. The standard requires harmonic and interharmonic measurement supporting window widths of 50 Hz/60 Hz, 10/12 cycles.
Support of the IEC 61000-4-15 Ed1.1 /Ed2.0.
The flicker meter standard that defines the requirements of the measurement equipment and test method of voltage fluctuation and flicker measurement.
Support of the IEC61000-3-3 Ed2.0 and Ed3.0
The measurement and judgment procedure of the Voltage fluctuation and Flicker requires above international standards as well.
Revision History
Version
Date
Contents
6.71
Jun 30, 2021
New function
<IEC61000-3-2>
Supported IEC61000-3-2 Ed5.0.
6.55
Mar 9, 2018
Bug fixed:
<IEC61000-3-3> and <IEC61000-3-11>
Fixed a bug that terminates the measurement before finishing the specified number of measuring times. That occurs rarely in previous version 6.52.
Fixed a bug that appears an error after the dmax measurement finished one time by manual way.That occurs rarely in previous version 6.52.
6.52
Oct 28, 2016
New functions:
<ALL>
Supported Windows 10.
<IEC61000-3-2>
Supported IEC61000-3-2 Ed4.0.
Previous version
Previous version
Version
Date
Contents
6.43
Sep 15, 2015
Bug fixed:
<IEC61000-3-2>
Fixed a bug occurring when saving file in CSV format if the specified input element number is not '1'.
6.42
Aug 3, 2015
Bug fixed:
<IEC61000-3-3>
Revised Edition display when reading data saved by former version of Ver. 6.31 or before.
Revised failure of re-calculation and re-judgment by Edition 3.0 for saved data setting by previous Edition 2.0.
6.41
Jun 29, 2015
New function:
<IEC61000-3-3>
Support IEC61000-3-3 Ed3.0
6.31
Jul 10, 2014
New function:
<IEC61000-3-12>
Support IEC61000-3-12 Ed2.0
6.23
Mar 28, 2014
Bug fixed:
<All standard of IEC61000-3>
Revised read operation of the setting information files for less than 3 input elements model.
<IEC61000-3-3>
Revised title of IEC61000-3-11 of test report to IEC61000-3-3.
6.21
Jan 31, 2014
New functions:
<IEC61000-3-2>
Added the numeric values report function, when select Power Range of Class C >25W.
<IEC61000-3-3>
Added support for IEC61000-4-15 Ed2.0 standard (WT3000 Firmware:Ver5.21).
<IEC61000-3-11>
Added support for IEC61000-4-15 Ed2.0 Standard (WT3000 Firmware:Ver5.21).
6.15
Mar 8, 2013
New functions:
<IEC61000-3-2>
Supported long period measurement up to 18 hours for single phase measurement
Bug fiexed:
<IEC61000-3-2>
Added [apply limit value of Class C (Dimming lights)] of Power Range for Class C >25W and did not judge within +/-10% of fundamental current and PF.
Fixed bug of confliction between software (ON) and WT3000 (OFF) when select [Same Condition as Last Execution] under scaling ON condition.
<IEC61000-3-12>
Fixed bug of scaling value of graph display when CT's were used.
Fixed bug of lack of numeric values when Ssc value were big condition.
6.11
Apr 27, 2012
New functions:
<All>
Supports both 2A input element models and 2A/30A mixed input element model
Supported under Windows7 OS (32-bit and 64-bit)
Supported with GPIB-USB-HS Controller from National Instrument (however, please note National Instruments 488.2 Driver Version 2.8.1 or later is required.)
Supports PDF output function
<IEC61000-3-2>
Added support for IEC61000-3-2 Ed 3.0 Am2 (Waveform judgment for Class C equipment less than 25W and Simple test)
Added support for JIS C 61000-3-2 2011(Similar to IEC61000-3-2 Ed 3.0 Am2)
<IEC61000-3-12>
Added support for IEC61000-4-7 Ed 2.0 Am1(Added Ed 2.0 Am1, and Ed 1.0)
6.02
Nov 1, 2010
Bug fiexed:
<IEC61000-3-2>
Change in calculation method for current limit of Class C and D equipments.
When using zoom function, printing results were limited only to zoomed waveforms. Revised the zooming and printing functions to illiminate this limitation.
6.01
Oct 22, 2009
New functions:
<IEC61000-3-2>
New GUI Opeartion (WT3000 only)
Added support for the IEC61000-4-7 Ed1.0 and Ed2.0 Am1 standard
* WT3000 firmware Ver4.11 or later requires Expanded comment input from100 characters to 600 characters on report
<IEC61000-3-3>
New GUI Opeartion (WT3000 only)
Added new PASS judge:PASS(under dmin)
Expanded comment input from100 characters to 600 characters on report
<IEC61000-3-12>
Added support for the IEC61000-3-12 standard*
*Limitation for harmonic currents produced by equipment connected to public low-voltage systems with input current over 16A and up to 75A
Bug fixed:
<IEC61000-3-2>
Fixed a bug with the repeatability of the measurement according to Ed3.0 Am1.
Fixed a bug in which the software unexpectedly changed the setting standard to IEC.
5.11
Nov 4, 2008
New functions:
<IEC61000-3-2>
Added support for harmonic current limits judgment according to Ed3.0.
Bug fixed:
<IEC61000-3-2>
Fixed a bug with the repeatability of the measurement according to Ed3.0 Am1.
Fixed a bug in which the software unexpectedly changed the setting standard to IEC.
5.06
Jun 17, 2008
New functions:
<IEC61000-3-12>
Expanded the number of Ssc digits displayed in reports (12-digit integer with 2 decimal places).
Bug fixed:
<IEC61000-3-12>
Fixed a bug with the system impedance input range (before fix: 0.01···, after fix: 0.001···)
Fixed a bug in which the software unexpectedly stopped if the PC entered a power saving mode.
Fixed a bug in which the link between specified test conditions (rated current) and the standard (rated current) could not be made.
Fixed a bug in which newly-specified voltage/frequency values reverted to previous settings.
Fixed a bug in which the displayed value of the impedance item in reports differed from the set value.
Fixed a bug in the wiring system when "single-phase 2-wire, 230 V, 50 Hz, for instruments" was selected in which the wrong 3-phase limit value was used when determination of the limit value to be applied was automatic.
5.03
Jan 31, 2008
Bug fixed:
<IEC61000-3-11>
Fixed a bug in which a portion of the numerical display of reports was missing (when UndefError occurred).
<IEC61000-3-12>
Fixed a bug with system impedance input in which only two decimal places were displayed (corrected to 4 decimal places).
Fixed a bug in which only up to six digits of the SSC value in reports could be displayed (corrected to 12-digit integer with 2 decimal places).
5.01
Jan 10, 2008
New functions:
<IEC61000-3-11>
Added support for the IEC61000-3-11 standard*
* Voltage change, voltage fluctuation, and flicker suppression for instruments requiring connection at 75 A or less.
<IEC61000-3-12>
Added support for the IEC61000-3-12 standard*
* Harmonic current limit value of instruments above 16 A and less than or equal to 75 A.
4.02
Jun 26, 2007
Bug fixed:
<IEC61000-3-2>
Fixed bugs including one related to the power factor λ used with the 3rd order harmonic on the WT3000)
4.01
Jan 9, 2007
New functions:
Corresponds to IEC61000-3-3 2005. (WT3000 only)
3.01
Mar 20, 2006
New functions:
The WT3000 was added to the compatible instruments in the English version.
Corresponds to IEC61000-4-7 2002. (WT3000 only) The online help changes into PDF from HTML. (WT3000/WT2000/WT1600)
2.11
Feb 16, 2005
Bug fixed:
Communication fails with two or more GPIB addresses.
2.02
Jul 8, 2003
New Functions:
Added the WT1600 Digital Powermeter as a supported measuring instrument
Bug fixed:
Improved data acquisition method when connected to the WT2000 Digital Powermeter
1.02
Mar 13, 2003
New Functions:
Added exponential averaging
Bug fixed:
Changed waveform display: CF=2
1.01
Jan 9, 2003
Bug fixed:
Changed error message used during initialization of communication
How to Install the Upgrade Version of the Software
When upgrading Harmonic Analysis Software , 761922, it is necessary to inherit some information from the previous version you used. Therefore, it is necessary to temporarily save those files specified below when installing the upgrade version, and restore them after the installation. The procedure including the installation is as follows.
Download the upgraded version.
Create another folder and temporarily save the installed files shown below.
Example of condition of Windows 7
C: \Program Files\YOKOGAWA\IEC61000 Analysis Software\IEC61000.exe
Uninstall the previous version.
Unzip the downloaded upgrade version file. It creates IEC61000 Analysis Software folder.
Double-click IEC61000_Installer.exe located in the folder. The installer will launch.
Follow the on-screen instructions to proceed with the installation.
.After installing the upgrade version, restore those files saved in above 2. to the original folder.
Start the software by selecting → Programs → Yokogawa → IEC61000 Analysis Software → IEC61000 from the START menu
Note
To upgrade the 761922 software program, the previous version of the software must be installed in your PC.
Please read the "Software/Firmware Agreement" before proceeding to download the upgrade version of the software.
Do not attempt to upgrade the trial version! Doing so may cause your PC to malfunction. Yokogawa Electric Corp. assumes no liability for damages caused by attempts to upgrade the trial version.
Download
Please read Software Agreement carefully before downloading.
Version
6.71
Release Date
Jun 30, 2021
File Name
harm671.zip
394 MB
Type
Software* Registration is required to download.
* Softwarevereinbarung
Die Schutzrechte, Eigentumsrechte, Rechte an geistigem Eigentum und alle anderen mit der Software verbundenen Rechte werden von der Yokogawa Test & Measurement Corporation gehalten.
Unter keinen Umständen ist ein Dumping, Dekompilierung, umgekehrter Aufbau, Rückwärtsentwicklung oder jede andere Art von Änderung oder Revision dieser Software erlaubt.
Diese Software wird kostenlos angeboten, aber es werden keine unbegrenzten Garantien gegen jegliche Mängel gemacht.
Auch ist Yokogawa nicht in der Lage, Anfragen zur Reparatur von Mängeln oder Fragen zu dieser Software zu akzeptieren.
Der Inhalt dieser Software kann ohne vorherige Ankündigung geändert werden, da die Software und die Funktionen der Software weiter verbessert werden.
Yokogawa haftet nicht für Probleme, die während des Downloads oder der Installation dieser Software auftreten können.
Die Nutzung der Yokogawa-Website erfolgt auf eigene Gefahr.
Alle Parteien, die zur Erstellung oder Verbreitung der Inhalte auf der Yokogawa-Website beitragen, haften nicht für Schäden, die durch die Verwendung dieser Inhalte entstehen.
Das Herunterladen der Software zeigt die Zustimmung zu der Softwarevereinbarung .