AQ7932 is the application software that performs the analysis of trace data measured by a Yokogawa OTDR on a PC, and generates reports. The report generation wizard makes this task simple. OTDR data can be easily loaded onto a PC using USB memory or communication interface. This software is intended to upgrade the AQ7932 OTDR to new version.
By downloading the successor software, AQ7933, you get the latest features. In order to ensure that you can work comfortably, we recommend that you get the latest version of AQ7933.
AQ7270 series, AQ7275 series, AQ1200 series, AQ7280 series, AQ1000 series, and AQ1210 series
Remarks
Please read following update procedures before performing the installation.
Download the new software version in zip format (AQ7932VUpxxxEN.zip/ AQ7932VUpxxxCH.zip/ AQ7932VUpxxxKO.zip) into any temporary folder.
After downloading and unzipping the zip file, InstallLanguageSelect.exe will appear.
Execute InstallLanguageSelect.exe to start the installation.
Select the language of the program from the pull-down menu.
Click [OK] so that setup wizard window will appear.
To follow the instructions, AQ7932 OTDR Emulation Software will be installed.
*Uninstall the current version program. Follow "Control Panel" → "Add/Remove Programs". Select "AQ7932 Emulation Software" to uninstall it.
Revision History
Version
Date
Contents
7.04
Dec 9, 2022
Added function
Supported AQ7286A, AQ7286H, AQ7286J and the event analysis algorithm of the AQ7280 Ver. 3.01
Improved function
Applied to the contents of AQ1210 Ver. 1.07
7.03
Jan 24, 2022
Added function
Support for the event analysis algorithm of the AQ1210 Ver.1.06
7.02
Oct 23, 2020
Added function
Supported AQ1210D OTDR
Improved function
Improved the event search algorithm of AQ1210 Series OTDR
Previous version
Previous version
Version
Date
Contents
7.01
Jun 21, 2019
Added function
Supported AQ1210 Series OTDR
6.02
Jul 18,2018
Improved function
Improved the function to convert the labels of SOR files at once. Made it compatible with the latest SOR file version.
Improved the pass/fail judgment results and judgment conditions on and after the second page of report.
6.01
May 19,2017
Added function
Supported AQ1000 OTDR.
Improved function
Improved the event search algorithm of AQ7277B Remote OTDR.
5.05
Mar 27,2017
Improved function
Applied new event search algorithm as AQ7280 R2.03.
5.04
Aug 17,2016
Added function
Supported the New OTDR units of AQ7280 (AQ7283E, AQ7282G, AQ7283J).
5.02
Jul 24,2015
Improved functions
Added a detection of serial reflections.
Improve the detection in 256000 sampling point data.
Improve the character garbling in report printing.
5.01
Nov 13,2014
Improved functions
AQ7280 is supported.
Able to save the scale information to .SOR file.
4.05
Nov 01,2013
Improved functions
Applied new event search algorithm as AQ1200 R2.03.
4.04
Apr 19,2013
Improved functions
Added function of unzip from MPZ(result file of multi core measurement by AQ1200) file to MPJ/SOR files
Detect splitter in event searching.
4.02
Oct 28,2011
Improved functions
Shows connection loss of END point in event list
Shows total loss in list.
Adds section analysis function.
Non-auto search mode function available.
Adds some report format.
Adds event information to trace report head.
Unifies format of CSV out to format of mainframe.
Expands file of Multi core trace comparison,Modification.
4.01
May 18,2010
Modification
AQ1200 MFT-OTDR Compatible
Supported AQ1200MFT-OTDR's file format
Trace Report Output
Added a check box for "Marker and cursor setting" to Report master setting.
When selected, the Marker and cursor information of the recalled master file is reflected in the master setting.
Added "Code no. step" to the Waveform file information setting in Report setup mode.
The step to increase the core number can be changed.
3.05
Feb 23,2009
Modification
Supports new models
Supports new models which were introduced in Dec. 2008
Trace Report Output
In Trace Report mode, added selection Valid or Invalid. for master setup.
When Invalid is selected, report can be output without master setting.
Added the following items to Trace Header.
- "Return Loss"
- "Date/time stamp"
Added check box "use trace information" in report tile setting page.
This setting is available for only "1 trace per page" layout
Master event location Fix function
Added check box "keep master events position".
When this box is checked,master events are always applied for report.
Calculation method for Cumulative loss
Added selection whether Near end loss is included or not included to Cumulative loss
Total Table Report Output
Added check box "Add a end point's loss" in setting of Total Table Report Output.
Other language support
Added French and Polish
3.04
Dec 13,2008
Modification
Change setting range for Event search function
Setting range for end point detection : 3 to 65dB
Solved problem during software version up on Windows Vista OS
3.03
Nov 09,2007
Windows Vista has been added to the recommended Operating System(OS) of PC
3.02
―
New function
5 point markers mode is added
5 point markers (n/N/E/F/f) mode can be selected in Trace setup of Trace Screen Setup.
BMP file type is added in File Batch conversion function
[BMP (*.BMP)] file type is added to the conversion type.
File format is AQ7270/60 type. (Black and white)
Modification
Sort function is improved at [File Select]
Files can be sorted according to numbers in file names.
Blank column setting is added to File Select at Report function
<Set Blank> button is added to File Select dialogue.
<Set Blank> is available at both Trace and Total table. Blank column can be inserted in the data for print.
Restriction of File Select is eased at Trace and Total table in Report function
The traces with different file types can be applied to 2 way trace files as far as wavelengths are the same.
Master Event Setup can be performed even if the files have different measurement conditions at either 1way or 2way, as far as wavelengths are the same.
3.01
Jul 03,2007
Supports AQ7270.
2.01
Mar 10,2005
Supports AQ7269 (4 wavelength[MMF/SMF] module).
1.05
Dec 04,2005
Initial version at First Delivery
Download
Please read Software Agreement carefully before downloading.
Version
7.04
Release Date
Dec 9, 2022
File Name
AQ7932VUp704EN.zip (English)
4.39 MB
AQ7932VUp704CH.zip (Chinese)
6.27 MB
AQ7932VUp704KO.zip (Korean)
6.25 MB
Type
Software* Registration is required to download.
* Softwarevereinbarung
Die Schutzrechte, Eigentumsrechte, Rechte an geistigem Eigentum und alle anderen mit der Software verbundenen Rechte werden von der Yokogawa Test & Measurement Corporation gehalten.
Unter keinen Umständen ist ein Dumping, Dekompilierung, umgekehrter Aufbau, Rückwärtsentwicklung oder jede andere Art von Änderung oder Revision dieser Software erlaubt.
Diese Software wird kostenlos angeboten, aber es werden keine unbegrenzten Garantien gegen jegliche Mängel gemacht.
Auch ist Yokogawa nicht in der Lage, Anfragen zur Reparatur von Mängeln oder Fragen zu dieser Software zu akzeptieren.
Der Inhalt dieser Software kann ohne vorherige Ankündigung geändert werden, da die Software und die Funktionen der Software weiter verbessert werden.
Yokogawa haftet nicht für Probleme, die während des Downloads oder der Installation dieser Software auftreten können.
Die Nutzung der Yokogawa-Website erfolgt auf eigene Gefahr.
Alle Parteien, die zur Erstellung oder Verbreitung der Inhalte auf der Yokogawa-Website beitragen, haften nicht für Schäden, die durch die Verwendung dieser Inhalte entstehen.
Das Herunterladen der Software zeigt die Zustimmung zu der Softwarevereinbarung .