Overview
Inverter and motor controlled by ECUs in electric vehicles (EV) require even higher levels of control and responsiveness.
In addition to confirming the operation of the control program, it is becoming increasingly important to comprehensively measure the control program instructions and the actual operation of the inverter motor, and to evaluate their behavior, responsiveness, validity, etc.
In order to perform these evaluations, the CAN / CAN FD data from the ECU, the battery output, the internal control and output voltage/current of the inverter, and the torque / rotation speed of the motor must be integrated and measured.
Points
In waveform measurement of high voltage or large current, there is a possibility of short circuit, electric shock accident or damage of the measuring instrument caused by insulation failure, wrong wiring, over-input, etc. In order to prevent such accidents, it is important that the measurement instrument has an isolated input. The ScopeCorder Series, including the DL950, offers a variety of isolated input modules, including up to 1000 V input modules.
Voltage and current of various motors and control systems, motor rotation speed, battery voltage fluctuation, vibration, noise, temperature, strain, etc. may be measured simultaneously. The DL950 has a maximum of 32 channels, and a 5-unit synchronization provides up to 160 channels.
High-speed sampling is required to understand sudden voltage fluctuations in inverters and batteries. The DL950 is capable of sampling up to 200 MS/s. You can also set a different sample rate for each channel, reducing the amount of data combined with slower sample channels such as temperature.
The in-vehicle serial bus data of CAN / CAN FD, LIN, SENT can be displayed by trend. For example, vehicle speed data on CAN FD can be measured simultaneously with sensor outputs such as voltage and current of motor drive, motor speed, temperature and vibration.
Features
The DL950 can display waveform data of various signals of the inverter/motor, and simultaneously display data of the in-vehicle serial bus such as CAN / CAN FD, LIN, SENT by trend.
Calculate torque value and rotational speed with real-time calculation function
The CAN/CAN FD bus data and related waveforms can be viewed on the same screen. For example, an ignition switch ON/OFF signal, a CAN FD signal corresponding to that command, and pressure signals can be checked on the same screen to verify the correlation between them.
The Yokogawa DL950 ScopeCorder captures and analyzes a wide variety of electrical, physical sensor signals, and serial buses. It offers a unique combination of high sampling rates, for a detailed view and long recording times to monitor trends over time.
Die Datenerfassungssysteme von Yokogawa bieten Ihnen höchste Flexibilität und Leistungsfähigkeit zur Messung, Anzeige, Speicherung und sogar zur Auslösung unterschiedlichster physikalischer oder elektrischer Phänomene.
Erstklassige Digital-Oszilloskope von Yokogawa: Die Digital-Oszilloskope zeichnen sich durch eine hohe Abtastrate und eine große Auswahl von Bandbreiten aus und eignen sich für einen Einsatz im Design und der Entwicklung von elektronischen Bauteilen und Geräten. Die ScopeCorder kombinieren die Vorteile sowohl von einem Digital-Oszilloskop, als auch von einem mehrkanaligen Datenrecorder.
Unser Transienten-Rekorder ist eine flexible und leistungsfähige mehrkanalige Test- und Messlösung, welche die Vorteile von einem sehr präzisen Oszilloskop und einem konventionellen Datenrecorder kombiniert. Herausragend ist der modulare Aufbau mit meist galvanisch getrennten Eingangskanälen, die schnelle Abtastrate und hohe Auflösung von 12-, 14- und 16-Bit. Funktionen für einen kombinierten Betrieb von Oszilloskop und Recorder sowie der History-Speicher komplettieren die Vielfalt der Applikationsanwendungen.