OSA: Measurement of LiDAR Testing Light Source for Autonomous Driving

Autonomous vehicles (AVs) are transforming transportation, turning futuristic dreams into present-day reality. The global market for AVs is fueled by advances in AI and sensor technology. A key technology in this application is Light Detection and Ranging (LiDAR), essential for precise, real-time 3D mapping and navigation. Companies worldwide are heavily investing in LiDAR R&D, testing, and manufacturing, to ensure their AVs can safely and effectively interact with the environment. This investment is driving rapid innovation, bringing us closer to a future shaped by self-driving cars.

LiDAR for autonomous driving 

Automotive LiDAR testing for autonomous driving

 

Understanding LiDAR Technology

LiDAR works by emitting laser pulses to measure distances, enabling the detection of obstacles and navigation. Elon Musk has criticized LiDAR, favoring a camera-centric approach due to cost and complexity. However, many companies rely on LiDAR for safety and redundancy in their self-driving systems. The debate over LiDAR's role in autonomous driving remains ongoing as the industry continues to evolve.

LiDAR technology operates on the principle of Time of Flight (ToF), where it measures the time it takes for laser pulses to travel to objects and back. From this data, LiDAR generates a detailed 3D map of the environment, including the location, size, and movement of objects. These maps assist vehicles to navigate safely, as they provide information about obstacles, pedestrians, lane markings, and other features in the surroundings.

LiDAR uses a pulsed infrared laser. The main laser wavelength is 800 to 900 nm, but LiDAR using the 1550 nm band laser, which is superior in terms of high output and low cost, is also under development. An optical spectrum analyzer is required to characterize these lasers.

Testing LiDAR Light Sources

While high-resolution mapping and precise object detection are imperative for safe navigation, companies face constraints such as optical power and scanning speed. The level of available optical power directly impacts accuracy; however, higher power also escalates operational costs. Additionally, scanning speed is critical for real-time data acquisition, yet it must be managed cautiously to avoid safety hazards, especially concerning laser frequencies harmful to human eyes.

LiDAR Test Using Optical Spectrum Analyzers

An optical spectrum analyzer (OSA) is used in LIDAR laser testing, offering detailed insights into the optical characteristics emitted by the laser. Here's how an OSA is typically used for LIDAR laser testing:

  • Wavelength Analysis: OSAs precisely measure the laser's wavelength, ensuring accuracy for specific LIDAR system requirements.
  • Wavelength Stability: OSAs monitor wavelength stability over time to ensure consistent and reliable distance measurements.
  • Power Measurement: OSAs assess optical power to verify compliance with safety standards and system performance requirements.
  • Spectral Characteristics: OSAs provide insights into spectral characteristics like linewidth and spectral width, essential for assessing laser coherence and accuracy.
  • Noise Analysis: OSAs detect and analyze noise in the laser beam, optimizing system performance and minimizing measurement uncertainties.

Optical spectrum measurement of laser for LiDAR

Optical spectrum measurement of laser for LiDAR testing procedures

Some OSAs aren't well-suited for LiDAR testing. When selecting the appropriate OSA, it's important to opt for a model compatible with a broad spectrum of wavelengths and capable of accommodating large diameter free space inputs.

LiDAR systems utilize pulsed infrared lasers. Most commonly, the main laser wavelength falls between 800 to 900 nm (infrared), with some LiDAR systems that employ the 1550 nm band laser (short wave infrared. Each wavelength range offers tradeoffs with respect to target reflectance and absorbance, background radiation, atmospheric transmission, and eye-safety.

Additionally, OSA’s are often used in combination with an optical power meter (i.e AQ2200 modular manufacturing test platform) for manufacturing acceptance and shipment inspection of laser parts.

In summary, OSAs are invaluable tools for characterizing and validating the laser's properties, ensuring the accuracy, stability, and safety of the LIDAR system.

Find the Right OSA for LiDAR Testing

Effective LiDAR signal analysis necessitates Optical Spectrum Analyzers (OSAs) with sufficient sensitivity and dynamic range, especially in challenging atmospheric conditions like fog and rain. All Yokogawa OSAs are equipped with grating technology, ensuring superior sensitivity down to -90 dBm. Additionally, the wavelength ranges commonly used in LiDAR (800-900 nm and 1550 nm) precisely align with communications signals. Leveraging over 40 years of experience in communications testing, 6 out of 8 OSA models cover at least one of the LiDAR wavelength ranges. Moreover, our OSAs feature built-in pulsed laser analysis, ensuring consistent and standardized results across the industry.

6 out of 8 OSA models cover LiDAR wavelengths

 


 

FAQs about OSAs and LiDAR testing


What can LiDAR not detect?

LiDAR has limitations in detecting transparent objects like glass or water, mirrors, fine details smaller than sensor resolution, subsurface features, materials with low reflectivity or high absorbance, and adverse weather conditions such as heavy rain, fog, or snow.

What are the three types of LiDAR?

The three main types of LiDAR are airborne, terrestrial, and mobile. Airborne LiDAR, mounted on aircraft or drones, captures data for large-scale mapping, forestry management, and urban planning. Terrestrial LiDAR, stationary or mobile, is used for detailed mapping of smaller areas like building interiors and archaeological sites. Mobile LiDAR, installed on vehicles or boats, captures data while in motion, commonly used for mapping roadways, railways, and city streets.

What does LiDAR stand for?

LiDAR stands for Light Detection and Ranging.

Related Products & Solutions

AQ6360 Produktions-OSA 1200 - 1650 nm

Der AQ6360 ist ein kostengünstiger optischer Spektrumanalysator der auf der Beugungsgitter-Technologie basiert. Ohne Bedienfeld und mit geringerer Größe ist er für die Anwendung in der Produktionsprüfung optischer Komponenten ausgelegt.

AQ6370B Optischer Spektrumanalysator

Setzt durch erstklassige Messmöglichkeiten einen neuen Standard für die optische Spektrumanalyse! 
 

AQ6370C Optical Spectrum Analyzer

Der AQ6370C verbindet außergewöhnlich hohe Genauigkeit und Auflösung mit hoher Dynamik, vielfältigen Schnittstellen und einfacher Bedienbarkeit.

AQ6370D Optischer Spektrumanalysator (EINGESTELLT)

Durch die Abdeckung des gängigen Telekommunikations-Wellenlängenbereichs von 600 nm bis 1700 nm ist dies ein ideales Instrument für Telekommunikationsanwendungen sowohl für Single-Mode- als auch Multi-Mode-Optik.
 

AQ6370E Telekom-OSA 600 - 1700 nm

Der optische Spektrumanalysator AQ6370E deckt die gängigen Wellenlängen für die Telekommunikation ab. Er ist vielseitig einsetzbar, da er aufgrund des Freistrahleingangs für Single-Mode und Multi-Mode Anwendungen geeignet ist.

AQ6373E VIS - OSA: 350 - 1200 nm

Der optische Spektrumanalysator AQ6373E ist in 3 Leistungs-Varianten erhältlich. Er eignet sich besonders für Messungen im sichtbaren Spektrum und für Laser wie sie in industriellen, biologischen und medizinischen Bereichen Anwendung finden.  

AQ6374 Optischer Breitband-Spektrumanalysator (EINGESTELLT)

Der optische Breitband-Spektrumanalysator AQ6374 deckt den Wellenlängenbereich von 350 bis 1750 nm und damit sowohl den Bereich des sichtbaren Lichts (380 bis 780 nm) als auch die im Telekommunikationsbereich genutzten Wellenlängen ab.
 

AQ6374E Breitband OSA 350 - 1750 nm

Der optische Breitband-Spektrumanalysator AQ6374E deckt sowohl den Bereich des sichtbaren Lichts (380 bis 780 nm) als auch die in der Telekommunikation genutzten Wellenlängen ab. Er eignet sich für vielfältige Anwendungen sowie die Bewertung von Lichtwellenleitern. 

AQ6380 Hochleistungs-OSA 1200 - 1650 nm

Der optische Spektrumanalysator AQ6380 bietet mit bis zu 5 pm Auflösung und einer Close-In Dynamik von 65dB eine unerreichte optische Performance. Damit genügt er höchsten Anforderungen, vor allem im Bereich der Telekommunikation. 

Optische Messtechnik

Yokogawa bietet Lösungen für Messungen sowohl an konventionellen, als auch an modernsten optischen Komponenten und Systemen für die Nachrichtentechnik und die allgemeine Optik an. Derartige Messungen werden besonders bei optischen Fasern mit hoher Kapazität und neuen Bauteiltechnologien immer wichtiger. Bei Yokogawa wird dabei ein Wellenlängenbereich vom sichtbaren bis in den infraroten Bereich um 2,5µm abgedeckt.

Optische Spektrumanalysatoren

Yokogawa gehört mit der Produktlinie der hochwertigen und innovativen optischen Spektrumanalysatoren (OSA) zu den weltweiten Marktführern bei der optischen Wellenlängen-Messtechnik. Auf der Basis unserer mehr als dreißigjährigen Erfahrungen in diesem Bereich ergänzen wir unsere OSAs nun mit optischen Wellenlängen-Messgeräten als komplementäre Lösung. Die optischen Wellenlängen-Messgeräte von Yokogawa erlauben schnelle, genaue und dennoch kostengünstige optische Wellenlängen-Messungen entsprechend den derzeitigen und künftigen Anforderungen und im Hinblick auf den weltweit schnell zunehmenden Datenverkehr in den Netzen.

Precision Making

Oben